2

4
certain industrial chemicals, and bleach or bleach
containing products, etc., can cause a short circuit.
• Maintain labels and nameplates. These carry im-
portant information. If unreadable or missing, contact
a MILWAUKEE service facility for a free replacement.
•
WARNING
Some dust created by power sanding,
sawing, grinding, drilling, and other
construction activities contains chemicals known to
cause cancer, birth defects or other reproductive harm.
Some examples of these chemicals are:
• lead from lead-based paint
• crystalline silica from bricks and cement and other
masonry products, and
• arsenic and chromium from chemically-treated lumber.
Your risk from these exposures varies, depending on
how often you do this type of work. To reduce your
exposure to these chemicals: work in a well ventilated
area, and work with approved safety equipment, such
as those dust masks that are specially designed to
lter out microscopic particles.
FUNCTIONAL DESCRIPTION
1
2
9
54 3
8
7
1. Handle
2. Pressure gauge
3. Motor/On button
4. Max water line
5. Coupler
6. Pressure gauge
selector
7. Pressure gauge cap
8. LED
9. Air release trigger
10. Battery bay
10
6
SPECIFICATIONS
Cat. No. 2572-20 ..........................................................
Volts ...................................................................12 DC
Air Pressure ...................................................0-50 PSI
Battery Type ..................................................... M12™
Charger Type .................................................... M12™
SYMBOLOGY
Volts
Direct Current
CUS
UL Listing Mark for
Canada and U.S.
Do not allow battery to contact corrosive
or conductive uid
Wear face shield
Wear latex or rubber gloves
• Under abusive conditions, liquid may be ejected
from the battery; avoid contact. If contact ac-
cidentally occurs, ush with water. If liquid con-
tacts eyes, additionally seek medical help. Liquid
ejected from the battery may cause irritation or burns.
• Do not use a battery pack or tool that is damaged or
modied. Damaged or modied batteries may exhibit
unpredictable behavior resulting in re, explosion or
risk of injury.
• Do not expose a battery pack or tool to re or ex-
cessive temperature. Exposure to re or temperature
above 265°F (130°C) may cause explosion.
• Follow all charging instructions and do not charge
the battery pack or tool outside the temperature
range specied in the instructions. Charging im-
properly or at temperatures outside the specied range
may damage the battery and increase the risk of re.
SERVICE
• Have your power tool serviced by a qualied repair
person using only identical replacement parts.
This will ensure that the safety of the power tool is
maintained.
• Never service damaged battery packs. Service of
battery packs should only be performed by the manu-
facturer or authorized service providers.
SPECIFIC SAFETY RULES
• Use latex or rubber gloves, a face shield and pro-
tective clothing when chemicals, bacteria or other
toxic or infectious substances are suspected to be
in a drain line. Drains may contain chemicals, bacteria
and other substances that may cause burns, be toxic
or infectious or may result in other serious personal
injury.
• Practice good hygiene. Do not eat or smoke while
handling or operating the tool. After handling or
operating drain cleaning equipment, use hot, soapy
water to wash hands and other body parts exposed
to drain contents. This will help reduce the risk of health
hazards due to exposure to toxic or infectious material.
• Only use the drain cleaner for the recommended
drain sizes.
• Inspect the drain to be cleaned before use. Do not
use on pipes and ttings that are compromised. If
possible, determine the access point(s) to the drain, the
size(s) and length(s) of the drain, distance to mainlines,
the nature of the blockage, presence of drain clean-
ing chemicals or other chemicals, etc. If chemicals
are present in the drain, it is important to understand
the specic safety measures required to work around
those chemicals. Contact the chemical manufacturer
for required information.
• If needed, place protective covers in the work area.
The drain cleaning process can be messy.
• Do not point the tool towards yourself or anyone
nearby. Unexpected triggering will discharge the air
pressure causing an injury.
• Do not actuate the tool unless the tool is placed
rmly against the workpiece.
If the tool is not in con
-
tact with the workpiece, air pressure may be deected
away from your target.
• Do not engage in horseplay. The discharged air
pressure is capable of causing serious injury.
• Use the tool only for the intended purposes. Do
not abuse the tool.
•
WARNING
To reduce the risk of re, personal in-
jury, and product damage due to a
short circuit, never immerse your tool, battery pack or
charger in uid or allow a uid to ow inside them.
Corrosive or conductive uids, such as seawater,
Specyfikacje produktu
Marka: | Milwaukee |
Kategoria: | Niesklasyfikowane |
Model: | M12 AirSnake 2572B-21 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Milwaukee M12 AirSnake 2572B-21, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Milwaukee
12 Stycznia 2025
8 Stycznia 2025
29 Grudnia 2024
26 Grudnia 2024
12 Grudnia 2024
14 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
Instrukcje Niesklasyfikowane
- Niesklasyfikowane OXO Good Grips
- Niesklasyfikowane Gembird
- Niesklasyfikowane EOTech
- Niesklasyfikowane Reebok
- Niesklasyfikowane Envertec
- Niesklasyfikowane Seenergy
- Niesklasyfikowane Needit
- Niesklasyfikowane Cadel
- Niesklasyfikowane TC Electronic
- Niesklasyfikowane Bimar
- Niesklasyfikowane Califone
- Niesklasyfikowane W'eau
- Niesklasyfikowane Domyos
- Niesklasyfikowane TeachLogic
- Niesklasyfikowane Kenwood
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025