Instrukcja obsługi Moxa NPort IA-5150-S-SC
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Moxa NPort IA-5150-S-SC (4 stron) w kategorii serwer. Ta instrukcja była pomocna dla 9 osób i została oceniona przez 5 użytkowników na średnio 4.3 gwiazdek
                        Strona 1/4
                    
                    
                    
  — 1 —  — 2 —  — 3 — 
NPort IA5150/5250 Series 
Quick Installation Guide 
Fourth Edition, September 2008 
1. Overview 
NPort IA device servers deliver easy and reliable serial-to-Ethernet 
connectivity for the industrial automation market. The servers support 
several operation modes—TCP Server, TCP Client, UDP, Real COM, 
Pair Connection, and Ethernet Modem—ensuring the compatibility of 
network software, and are an ideal choice for connecting 
RS-232/422/485 serial devices, such as PLCs, sensors, meters, motors, 
drives, barcode readers, and operator displays. NPort IA device servers 
come with a compact and rugged DIN-Rail mountable casing. 
2. Package Checklist 
Before installing NPort IA device servers, verify that the package 
contains the following items: 
• 1 NPort IA Series Device Server 
• Documentation and Software CD 
y NPort IA Series Quick Installation Guide 
Optional Accessories 
y DR-4524  45W/2A DIN-Rail 24 VDC Power Supply with 
universal 85 to 264 VAC input 
y DR-75-24  75W/3.2A DIN-Rail 24 VDC Power Supply 
with universal 85 to 264 VAC input 
y DR-120-24  120W/5A DIN-Rail 24 VDC Power Supply with 
88 to 132 VAC/176 to 264 VAC input by switch 
Notify your sales representative if any of the above items is missing or 
damaged. 
3. Hardware Introduction 
NPort IA device servers are used to control RS-232/422/485 devices 
for industrial automation environments. Six of the models have 1 
RS-232/422/485 serial port. NPort IA5150, NPort IA5150I, NPort 
IA5150-M-SC, NPort IA5150I-M-SC, NPort IA5150-S-SC, and NPort 
IA5150I-S-SC have 1 male DB9 port for the RS-232 interface, and a 
5-pin terminal block for the RS-422/485 interface (only one port can be 
used at a time). One model has 2 RS-232/422/485 serial ports. NPort 
IA5250 has two male DB9 ports for all interfaces. 
NPort IA5150 Series Appearance 
Reset
Top View Bottom ViewFront View
Reset
V1
V1+
V2
V2+
1
Dual power input 
and relay output
PWR1
PWR2
RDY
P1
FX
IA
5150-M-SC
Fiber optic
Ethernet
RS-232 RS-422/485P1
RS-232
RS-422/485
LED
Indicators
NPort IA5250 Appearance 
PWR1
PWR2
RDY
P1
Ethernet 1
Ethernet 2
Reset
5250
IA
P2
Copper
Ethernet
LED
Indicators
Top View Bottom ViewFront View
Reset
V1
V1+
V2
V2+
1
Dual power input 
and relay output
RS-232/422/485
RS-232/422/485P1 P2
Reset Button—Press the Reset button continuously for 5 sec to load 
factory defaults: Use a pointed object, such as a straightened paper clip or 
toothpick, to press the reset button. This will cause the Ready LED to 
blink on and off. The factory defaults will be loaded once the Ready LED 
stops blinking (after about 5 seconds). At this point, you should release 
the reset button. 
NPort IA LED Indicators (front panel) 
Name  Color Function 
PWR1, 
PWR2  red  Power is being supplied to power input PWR1, 
PWR2. 
red 
Steady on:  Power is on and NPort IA is booting 
up. 
Blinking:  Indicates an IP conflict, the DHCP 
or BOOTP server did not respond 
properly, or a relay output occurred. 
green
Steady on:  Power is on and NPort IA is 
functioning normally. 
Blinking:  The device server has been located 
by Administrator’s Location 
function. 
Ready
off  Power is off, or a power error condition exists. 
Orange 10 Mbps Ethernet connection. 
Green 100 Mbps Ethernet connection. 
Ethernet
off  Ethernet cable is disconnected, or has a short. 
orange Serial port is receiving data. 
green Serial port is transmitting data. 
P1, P2
off  No data is being transmitted or received through 
the serial port. 
FX  orange
Steady on:  Ethernet fiber connection, but port is 
idle. 
Blinking:  Fiber port is transmitting or 
receiving data. 
4. Hardware Installation Procedure 
STEP 1:  After removing NPort IA from the box, the first thing you 
should do is connect the power adaptor. Connect the 12-48 
VDC power line with NPort IA’s terminal block, or connect 
the DIN-Rail power supply with NPort IA’s terminal block. 
STEP 2:  Connect NPort IA to a network. Use a standard 
straight-through Ethernet cable to connect to a Hub or 
Switch. When setting up or testing NPort IA, you might find 
it convenient to connect directly to your computer’s Ethernet 
port. In this case, use a cross-over Ethernet cable. 
STEP 3:  Connect NPort IA’s serial port to a serial device. 
STEP 4:  NPort IA is designed to be attached to a DIN-Rail or 
mounted on a wall. The two sliders on NPort IA’s rear panel 
serve a dual purpose. For wall mounting, both sliders should 
be extended. For DIN-Rail mounting, start with one slider 
pushed in, and the other slider extended. After placing the 
NPort IA on the DIN-Rail, push the extended slider in to 
lock the device server to the rail. The two placement options 
are illustrated in the accompanying figures. 
P/N: 1802051500211
Specyfikacje produktu
| Marka: | Moxa | 
| Kategoria: | serwer | 
| Model: | NPort IA-5150-S-SC | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Moxa NPort IA-5150-S-SC, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje serwer Moxa
                        
                         2 Marca 2025
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            Instrukcje serwer
- QNAP
- Dual Bay
- Luxman
- ELAC
- Ibm
- Linksys
- AVerMedia
- EXSYS
- AMX
- Megasat
- Atlantis Land
- Buffalo
- Avocent
- Synology
- TRENDnet
Najnowsze instrukcje dla serwer
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         10 Marca 2025
                        
                    
                                                            
                        
                         10 Marca 2025
                        
                    
                                                            
                        
                         10 Marca 2025