S2205 (2U24)
MS-S322
Server System
User Guide

3
Contents
CPU & Heatsink ..........................................................................................................36
Assembly Overview 37 ...............................................................................................
Installing CPU & Heatsink 38 ....................................................................................
Memory 41 .......................................................................................................................
Recommended Memory Population 42 .....................................................................
Installing Memory Modules 44 ..................................................................................
M.2 M Key ....................................................................................................................45
Installing M.2 M Key 45 .............................................................................................
PCIe Add-in Card ........................................................................................................46
Installing PCIe Add-in Card 46 ..................................................................................
Installing Riser Card Assembly 47 ............................................................................
System Fan .................................................................................................................48
Installing 2U Fan................................................................................................... 48
Installing 2U Fan Cage 49 .........................................................................................
Air Duct ........................................................................................................................50
Installing Air Duct 50 .................................................................................................
Power Supply Unit (PSU) ...........................................................................................51
Installing PSU 51 .......................................................................................................
Cable Routing .............................................................................................................52
Slide Rail .....................................................................................................................57
Disassembling Slide Rail 57 ......................................................................................
Installing Inner Rail to System 58 .............................................................................
Retracting Outer Rail Bracket 59 ..............................................................................
Attaching Outer Rail Bracket to Rack Frame 59 ......................................................
Installing System into Rack 60 ..................................................................................
Detaching Outer Rail Bracket from Rack Frame 61 .................................................
Detaching Inner Rail from System 61 .......................................................................

8System Specifications
SKUs S2205-04 S2205-04-10G
Rear Panel
∙1 x GbE RJ45 Port (mgmt.)
∙2 x USB 2.0 Type-A ports
∙1 x COM RJ45 port
∙1 x VGA port
∙1 x UID LED button*
*The UID LED button can also function as a by configuring jumper: J1_1.BMC reset button
TPM 1 x TPM header (with SPI interface)
Security TPM 2.0
Server
Management
∙1 x GbE RJ45 Port (mgmt.) (Realtek® RTL8211FD-CG)
∙1 x MicroSD card slot (for BMC log)
∙ASPEED AST2600 with AMI MegaRAC based firmware
-Supports IPMI 2.0 and DMTF Redfish® API
∙Dual BIOS and BMC supported
Cooling
∙2 x EVAC air cooling modules (for max 350W CPU)
∙6 x 6038 hot-swap system fans
∙1 x Air duct (2U height)
Environment
∙Operating Temperature: 0°C ~ 35°C
∙Non-operating Temperature: -20°C ~ 70°C
∙Non-operating Relative Humidity: 5% ~ 85% (non-condensing)
Power Supply (1+1) 1600W CRPS, 80 PLUS® Platinum
Certification CE, FCC (Class A)
Specyfikacje produktu
Marka: | MSI |
Kategoria: | serwer |
Model: | S2205-04-10G |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z MSI S2205-04-10G, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje serwer MSI
10 Marca 2025
10 Marca 2025
10 Marca 2025
10 Marca 2025
10 Marca 2025
10 Marca 2025
10 Marca 2025
10 Marca 2025
10 Marca 2025
20 Lutego 2025
Instrukcje serwer
- serwer Extron
- serwer Monacor
- serwer Opengear
- serwer Promise Technology
- serwer Mobotix
- serwer AMX
- serwer G-Technology
- serwer Iomega
- serwer Sitecom
- serwer ATen
- serwer SIIG
- serwer SEH
- serwer Atlona
- serwer NETSCOUT
- serwer Raritan
Najnowsze instrukcje dla serwer
9 Kwietnia 2025
2 Kwietnia 2025
2 Kwietnia 2025
2 Kwietnia 2025
28 Marca 2025
28 Marca 2025
28 Marca 2025
2 Marca 2025
2 Marca 2025
27 Lutego 2025