                        Strona 1/18
                    
                    
                    
a Quick start guide
Blood Pressure Monitor HCBL400WT
For more information see the extended manual online: ned.is/hcbl400wt
Intended use
This product is intended to measure the diastolic and systolic blood pressure and pulse rate 
of an adult.
The product is not intended for use on neonates, children or pregnant women.
This product is not intended for medical use.
The product is intended for indoor use only.
Any modication of the product may have consequences for safety, warranty and proper 
functioning.
Specications
 Product Blood Pressure Monitor
 Article number HCBL400WT
 Dimensions (l x w x h) 136 x 120 x 61 mm
 Weight (excl. batteries and cu) 225g
 Cu circumference 22 - 42 cm
 Measuring method Oscillometric method, automatic ination and measurement
Measurement range
 Cu pressure 0 - 300 mmHg
 Systolic 60 - 260 mmHg
 Diastolic 40 - 199 mmHg
 Pulse rate 40 - 180 beats/minute
Accuracy
 Pressure ± 3 mmHg
 Pulse rate Less than 60: ±3bpm
More than 60 (incl.) : ±5%
 Precision 1 mmHg
 Memory 2 x 60 measurements
 Battery type 4 x 1.5 V AA batteries (not included)
 Battery life Approximately 270 times
 Operating temperature 10 - 40 °C
 Storage temperature -20 - 50 °C
 Relative humidity ≤85 %
 Environmental pressure 80 - 105 kPa
Main parts  A(image  )
 1  Storage bag
2 Cu
 3  Rubber air tube
 4  Air tube connector
 5  Battery compartment
 6  Memory button
 7  Start button
 8  Irregular heartbeat indicator
 9  Low battery indicator
 q  Pressure in the cu is instable or there is a lot of 
remnant air in the cu
 w  Blood pressure level classication indicator
 e  Time and date display
 r  Systolic blood pressure
 t  Diastolic blood pressure
 y  Pulse rate
Safety instructions
 -
WARNING
 •  Ensure you have fully read and understood the instructions in this document before you 
install or use the product. Keep the packaging and this document for future reference.
 •  Only use the product as described in this document.
 •  Do not use the product if a part is damaged or defective. Replace a damaged or defective 
product immediately.
 •  Do not drop the product and avoid bumping.
 •  Do not expose the product to water or moisture.
 •  Only use the provided power cable.
 •  Disconnect the product from the power source and other equipment if problems occur.
 •  Do not unplug the product by pulling on the cable. Always grasp the plug and pull.
 •  This product may only be serviced by a qualied technician for maintenance to reduce the 
risk of electric shock.
 •  Consult with a doctor before use if you have any medical concerns.
 •  Do not use this product in a moving vehicle. This may result in inaccurate measurements.
Inserting the batteries  B(image  )
 1.  Open the battery compartment A5.
 2.  Place the batteries.
3.  Close A5.
Setting the time and date
 1.  Press and hold the start button A
7 and the memory button A6 simultaneously for two 
seconds.
The time format starts to blink. The product is now in time format adjustment mode.
 4If no button is pressed for 60 seconds, the product exits time and date adjustment mode.
2.  Press A6 to change the time format.
3.  Press A7 to conrm.
The product is now in year adjustment mode.
4.  Press A6 to adjust the number.
5.  Press A7 to conrm.
The product is now in month adjustment mode.
 6.  Repeat steps 4 – 5 to set the month, date, hour and minutes.
Connecting the cu
 1.  Insert the rubber air tube A3 into the air tube connector A4.
 4The connector must be completely inserted to prevent air leakage during blood pressure 
measurements.
Applying the cu
 1.  Place the cu A2 around a bare upper arm.
 4A2 must be placed 1-2 cm above the elbow joint.
 2.  Choose an arm to measure on. Always measure on the same arm.
 4If A2 is applied on the left arm, A3 must be on the inside of the arm, aligned with the 
middle nger.
 4If A2 is applied on the right arm, A3 must be at the side of the elbow.
 4A2 should be tight but comfortable. It should be possible to insert a nger between the 
arm and A2.
Body posture during measurement
Sitting down
 1.  Sit down.
 2.  Put your feet at on the oor.
 3.  Place your hand on a at surface with the palm up.
 4Do not rest your arm on A3. This may restrict the airow to A
2.
 4.  Position your arm so A2 is at the same height as your heart.
 5.  Sit calmly for 5 minutes before starting the blood pressure measurement.
Lying down
 1.  Lie on your back.
 2.  Place your arm straight along your side with the palm up.
 3.  Position your arm so A2 is at the same height as your heart.
 4.  Lie calmly for 5 minutes before starting the blood pressure measurement.
Measuring blood pressure
1.  Press A7.
 4All symbols - A8 to A
y - are shown on the display. If not all symbols are visible, contact 
the service center.
The current memory group starts to blink in the place of A
t.
 4Memory groups can be used to store measurements for multiple people on the same 
device.
2.  Press A6 to switch memory groups.
3.  Press A7 to conrm.
 4The memory group is also conrmed automatically after 5 seconds of inactivity.
The display shows the most recent measurements.
If no measurements are stored in the memory group, the display shows zeroes.
The product starts to seek zero pressure.
A2
 inates until sucient pressure has built up for a measurement.
A2
 slowly deates while the measurement is carried out.
The results are shown on the display.
 4The measurements are automatically stored.
4.  Press A7 to switch o the display manually.
 4The display switches o automatically after 1 minute of inactivity.
Reading measurements from the memory
1.  Press A6.
The current memory group is shown in the place of A
t.
2.  Press A7 to switch memory groups.
3.  Press A6 to conrm.
 4The memory group is also conrmed automatically after 5 seconds of inactivity.
The display shows the average values of all measurements in the current memory group.
If no measurements are stored in the memory group, the display shows zeroes.
4.  Press A6 to show the average values of the last three measurements in the current 
memory group.
5.  Press A6 to show the number of stored measurements in the current memory group.
6.  Press A6 to show the most recent measurements.
7.  Press A6 repeatedly to show the previous measurements.
8.  Press A7 to switch o the display manually.
 4The display switches o automatically after 1 minute of inactivity.
Deleting measurements from the memory
 1.  When the display shows a measurement, press and hold A
6 for three seconds to delete 
all measurements in the current memory bank.
Technical alarm
If the measured blood pressure is outside the rated range, the display shows ‘Hi’ or ‘Lo’ as 
technical alarm.
 1.  Check if the measurement was performed correctly.
 2.  If the measurement was performed correctly, consult your physician.
Specyfikacje produktu
| Marka: | Nedis | 
| Kategoria: | Monitor ciśnienia krwi | 
| Model: | HCBL400WT | 
| Kolor produktu: | Biały | 
| Typ wyświetlacza: | LCD | 
| Automatyczne wyłączanie zasilania: | Tak | 
| Wysokość produktu: | 185 mm | 
| Szerokość produktu: | 130 mm | 
| Głębokość produktu: | 90 mm | 
| Waga produktu: | 471 g | 
| Ilość na paczkę: | 1 szt. | 
| Przeznaczenie: | Przedramię | 
| Rodzaj baterii: | AA | 
| Model: | Automatyczny | 
| Liczba baterii: | 4 | 
| Napięcie baterii: | 1.5 V | 
| Battery life (CIPA standard): | 270 zdj. | 
| Gniazda pamięci: | 2 x 60 | 
| Jednostka miary: | mmHg | 
| Pomiar tętna: | Tak | 
| Rozkurczowe ciśnienie kwi: | Tak | 
| Skurczowe ciśnienie krwi: | Tak | 
| Rozmiar mankietu: | 22 - 24 cm | 
| Wykrywanie arytmii: | Tak | 
| Funkcja pamięci: | Tak | 
| Data na zdjęciu: | Tak | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Nedis HCBL400WT, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Monitor ciśnienia krwi Nedis
                        
                         25 Stycznia 2025
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         5 Września 2024
                        
                    
                                                            
                        
                         6 Sierpnia 2024
                        
                    
                                                            Instrukcje Monitor ciśnienia krwi
- Camry
- Lanaform
- TrueLife
- Magic Care
- Beurer
- Eks
- Kinetik
- Create
- Kogan
- Renpho
- SilverCrest
- Wellhealth
- Melissa
- Soehnle
- Omron
Najnowsze instrukcje dla Monitor ciśnienia krwi
                        
                         7 Kwietnia 2025
                        
                    
                                                            
                        
                         6 Kwietnia 2025
                        
                    
                                                            
                        
                         6 Kwietnia 2025
                        
                    
                                                            
                        
                         6 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025
                        
                    
                                                            
                        
                         4 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025