Instrukcja obsługi Panasonic GX-F12A-P


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Panasonic GX-F12A-P (2 stron) w kategorii przełącznik. Ta instrukcja była pomocna dla 23 osób i została oceniona przez 12 użytkowników na średnio 4.7 gwiazdek

Strona 1/2
ӕৢᛟଢ୿
ㄭធ࠮ࡦࠨ
ࡈ࡜࠶࠻ON ࡋ࠶࠼ON
GX-F12 GX-H12
MJECK-GXFH12 No.0014-11V
ߎ
ߩ߮ߚߪޔSUNX ߅޿ߍ޿ߚߛ߈ޔ޽߇ߣ
߁ߏߑ޿߹ߔޕ
ߏߩߦߎߩߊ߅ߺߦߥޔߒߊ
ᦨㆡߥᣇᴺߢߏ૶↪ߊߛߐ޿ޕ
ዏޔߎߩขᛒ⺑᣿ᦠߪᄢಾߦ଻▤ߒߡߊߛߐ޿ޕ
ᜩԓ
ᧄ⵾ຠߪޔ૕଻⼔↪ߩᬌ಴ⵝ⟎ߣߒߡߪ૶↪ߒߥ޿
ߢߊߛߐ޿ޕ
૕଻⼔ࠍ⋡⊛ߣߔࠆᬌ಴ߦߪޔOSHAޔANSI߅ࠃ߮
IECߩߩߦߔ߅ࠃ߮ߦ
ㆡวߔࠆ⵾ຠࠍߏ૶↪ߊߛߐ޿ޕ
Ɣ
Ɣ
1දʙ᪮
ᧄ⵾ߪޔᬺⅣߦ૶ߔࠆ⊛ߢ/⵾ㅧߐࠇߚ
⵾ຠߢߔޕ
಴ജߦߪޔ⍴⛊଻⼔࿁〝߇ⵝ஻ߐࠇߡ޿߹ߖࠎޕ㔚Ḯ
޽ࠆ޿ߪኈ㊂⽶⩄ࠍ⋥ធធ⛯ߒߥ޿ߢߊߛߐ޿ޕ
㔚Ḯᛩ౉ᤨߩㆊ󰶑⊛⁁ᘒ50msࠍㆱߌߡߏ૶↪ߊߛߐ
޿ޕ
ࠤ࡯ࡉ࡞ᑧ㐳ߪޔዉ૕ᢿ㕙Ⓧ߇0.3mm2એߩࠤ࡯ࡉ࡞
ࠍ૶↪ߒޔో㐳100m߹ߢน⢻ߢߔޕ
ᧄ⵾ຠࠍขࠅઃߌࠆ႐วߪޔM3࠽ࡌࡆ
ࠍ૶↪ߒ✦߼
ઃߌ࠻࡞ࠢߪ0.7Nmએߣߒߡߊߛߐ޿ޕ
2ዓ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
ᧄ␠ ޥ ޓᗲ⍮⋵ᤐᣣᏒ‐ጊ↸486-0901 2431-1
SUNXఇࡸ˟ᅈ URL : sunx.jp
<0568>33-7211
ᛛⴚ⋧⺣࠹࡟ࡈࠜࡦࠨ࡯ࡆࠬ 0120-394-205
ȕȪȸ
ȀǤȤȫ
ᛛⴚ⋧⺣ ࠨ࡯ࡆࠬFAX 0120-336-394
ȕȪȸ
ȀǤȤȫ
ฃઃᤨ㑆㧦᦬ᦐᣣ߆ࠄ㊄ᦐᣣߩ ᤨ㨪 ᤨ߅ࠃ߮ ᤨ㨪 ᤨ9 12 13 17
ૉߒޔ␸ᣣޔᐕᧃᐕᆎ╬ࠍ㒰ߊ
2010 5ᐕ ᦬
PRINTED IN JAPAN
NPN
⨥V
㤥಴ജ
㕍0V
100mA MAX.
1224V DC
%
⽶⩄
PNP಴ജ
⨥V
㤥಴ജ
㕍0V
100mA MAX.
1224V DC
%
⽶⩄
INSTRUCTION MANUAL
Inductive Proximity Sensor
Front sensing Top sensing
GX-F12 GX-H12
Thank you very much for using SUNX products. Please
read this Instruction Manual carefully and thoroughly for the
correct and optimum use of this product. Kindly keep this
manual in a convenient place for quick reference.
WARNING
Never use this product as a sensing device for person-
nel protection.
In case of using sensing devices for personnel protection,
use products which meet laws and standards, such as
OSHA, ANSI or IEC etc., for personnel protection appli-
cable in each region or country.
Ɣ
Ɣ
1CAUTIONS
This product has been developed / produced for indus-
trial use.
The output does not incorporate a short-circuit protec-
tion circuit. Do not connect it directly to a power supply
or a capacitive load.
Do not use during the initial transient time (50ms) after
the power supply is switched on.
Extension up to total 100m is possible with a 0.3mm2,
or more of conductor cross-section area cable.
In case of mounting this product, use a M3 pan head
screw, and the tightening torque should be 0.7N·m or
less.
2CONNECTION
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
NPN output
Load
(Black)
Output
(Blue) 0V
100mA max.
+
-
12 to24V DC
%
PRINTED IN JAPAN
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
Europe Headquarter: Panasonic Electric Works Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
Phone: +49-8024-648-0
US Headquarter: Panasonic Electric Works Corporation of America
629 Central Avenue New Providence, New Jersey 07974 USA
Phone: +1-908-464-3550
URL : sunx.com
SUNX Limited
May, 2010
PNP output
(Brown) +V
(Black)
Output
(Blue) 0V
100mA max. +
-
12 to24V DC
%
Load


Specyfikacje produktu

Marka: Panasonic
Kategoria: przełącznik
Model: GX-F12A-P

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Panasonic GX-F12A-P, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje przełącznik Panasonic

Instrukcje przełącznik

Najnowsze instrukcje dla przełącznik

Tork

Tork SS700ZA Instrukcja

9 Kwietnia 2025
Cudy

Cudy FS1024 Instrukcja

9 Kwietnia 2025
Elro

Elro FA624 Instrukcja

7 Kwietnia 2025
Lancom

Lancom GS-2426P Instrukcja

5 Kwietnia 2025
Lancom

Lancom GS-2412 Instrukcja

4 Kwietnia 2025
Lancom

Lancom GS-2412P Instrukcja

4 Kwietnia 2025
Lancom

Lancom GS-2426 Instrukcja

4 Kwietnia 2025
Hager

Hager ARF970D Instrukcja

3 Kwietnia 2025
Hager

Hager ARF920D Instrukcja

3 Kwietnia 2025