                        Strona 1/3
                    
                    
                    
SmartZone™ Network-Enabled MSPO Series 
Rack PDU (for Aggregate and Per Outlet Power Monitoring with Switching)  S P E C I F I C A T I O N S H E E T 
k e y   f e a t u r e s   a n d   b e n e f i t s
Aggregate 
power monitoring
Performs real-time Rack PDU aggregate and per outlet monitoring at the individual device level
Per outlet monitoring Per outlet monitoring provides data to determine if power distribution is accurate allowing for PUE calculation and individual 
servers to be identified as candidates for additional capacity, redeployment or decommissioning, improving overall data 
center efficiency; monitors current, voltage, kVA, kWhr, kW, Frequency, and Power Factor loads to monitor, document, and 
manage operational power utilization
Remote power 
monitoring and 
switching controls
Allow users to remotely access, configure, or manage units; or manage individual or a group of outlets such as turning 
outlets off that are not in use (preventing overloads) or recycling power to locked-up equipment, minimizing costly 
downtime and travel times to service equipment
Low profile breakers Low profile circuit breakers reduce the PDU depth preventing obstruction within the back of the cabinet
Time 
delay sequencing
Executes time delay sequencing of individual power outlets to avoid circuit overload due to the high in rush of current 
at equipment start up
Environmental 
monitoring
Includes two available ports for the connection of (optional) environmental sensors that monitor cabinet conditions 
such as temperature, humidity and airflow to facilitate capacity management and identify potential causes of 
equipment failure
Alarm thresholds  Enables users to define critical power or environmental thresholds that, if reached, will prompt alarm notifications for 
resolution to ensure operational resilience
LCD digital display Displays a visible on-unit warning when the current draw of rack PDU is close to the maximum Amp draw levels,  
helping to quickly identify and resolve concerns and avoid risk of overloaded circuits
Integrated
locking receptacle 
Protects against vibration and external elements that can easily dislodge external locking clips or guides; works with 
any standard IEC power cord
Customizable 
configurations
Offers standard or customizable builds with single or three phase options, a range of current ratings, and different 
power outlets that can be adapted for varying power requirements
SmartZone™ 
Software integration
Captures actionable power and environmental data that can be utilized by SmartZone™ Software to enable data 
center operational and energy efficiencies, capacity management, and resilience
t e c h n i c a l   i n f o r m a t i o n
Dimensions:                  32A or smaller vertical units: 70"H x 2.5"W x 2.36"D (1778mm x 64mm x 60mm)
                                      50A or larger vertical units: 70"H x 3.25"W x 2.36"D (1778mm x 82mm x 60mm)
                                      Horizontal units: 1.73"H x 17.0"W x 8.84"D (44mm x 432mm x 225mm)
Packaging:                     3-meter or 10 foot long power cord, screws, and tool-less button mounting
Mounting:                      Vertical power strips provide multiple outlets and do not occupy any rack spaces 
                                      Horizontal units mount via EIA 19" equipment mounting rails
Amperage ratings:         Global: 32 Amps
                                      NA: 20, 30, 60 Amps
s p e c i f i c a t i o n s
Network-Enabled MSPO (Monitored and Switched Per Outlet) Series Rack Power Distribution Units (PDUs) safely 
and efficiently manage and distribute power to installed equipment and are available in a range of electrical and outlet 
configurations that cover all global regions. Network-Enabled MSPO Series Rack PDUs have remote switching 
capabilities, enabling individual outlets or a group of outlets to be switched on or off to reboot equipment or restrict 
unauthorized use of individual outlets. Power monitoring at the individual outlet level provides actionable management 
data on the power consumption of each connected IT device enabling the redeployment or decommissioning of 
individual servers to reclaim available or under-utilized power capacity. The Rack PDU is connected directly to the 
network to provide local and remote monitoring of aggregate power, and environmental data, to quickly identify potential 
power issues and reclaim available or under-utilized power capacity. Network-Enabled MS Series Rack PDUs integrate 
with comprehensive DCIM software platforms, to access current and historical trending information and event 
notification alarms. For more specialized applications, Panduit offers a custom made service which involves designing 
and manufacturing a rack PDU to meet exact customer specifications.
www.pandu it.com
a p p l i c a t i o n s
The SmartZone™ Network-Enabled MSPO Series Rack PDU safely and efficiently manages and distributes power to multiple rack or cabinet 
devices via a single power connector. It can be deployed and utilized as a standalone “intelligent” rack PDU.  
The SmartZone™ Network-Enabled MSPO Series Rack PDU is available for order as standard “off-the-shelf” units for most common 
requirements, or as customized build configurations that are designed and manufactured to meet exact product requirements. 
The SmartZone™ Network-Enabled MSPO Series Rack PDU offers a variety of horizontal and vertical mounting options that support simple flexible 
installations for Panduit® Net-Access™ and Net-SERV ® Cabinets, or 2- and 4-post racks.  
As part of an fully intelligent data center or DCIM solution, the SmartZone™ Network-Enabled MSPO Series Rack PDU captures aggregate Rack 
PDU power and environmental data that can be used by SmartZone™ Software to more effectively manage and optimize operational efficiencies.
Specyfikacje produktu
| Marka: | Panduit | 
| Kategoria: | Listwa zasilająca | 
| Model: | Q1L2B1L2N24AFA0 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Panduit Q1L2B1L2N24AFA0, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Listwa zasilająca Panduit
                        
                         13 Września 2024
                        
                    
                                                            
                        
                         8 Września 2024
                        
                    
                                                            
                        
                         7 Września 2024
                        
                    
                                                            
                        
                         6 Września 2024
                        
                    
                                                            Instrukcje Listwa zasilająca
- Act
- Altronix
- GoGen
- Icy Box
- Gembird
- Eaton
- REV
- Ufesa
- DataVideo
- Legrand
- Vivanco
- Ewent
- Caliber
- Sven
- Yato
Najnowsze instrukcje dla Listwa zasilająca
                        
                         10 Marca 2025
                        
                    
                                                            
                        
                         10 Marca 2025
                        
                    
                                                            
                        
                         9 Marca 2025
                        
                    
                                                            
                        
                         27 Lutego 2025
                        
                    
                                                            
                        
                         21 Lutego 2025
                        
                    
                                                            
                        
                         20 Lutego 2025
                        
                    
                                                            
                        
                         20 Lutego 2025
                        
                    
                                                            
                        
                         14 Stycznia 2025
                        
                    
                                                            
                        
                         12 Stycznia 2025
                        
                    
                                                            
                        
                         31 Grudnia 2025