Instrukcja obsługi Perel E300GSM
Perel
Sprzęt pomiarowy
E300GSM
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Perel E300GSM (16 stron) w kategorii Sprzęt pomiarowy. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 3 użytkowników na średnio 5.0 gwiazdek
Strona 1/16

E300GSM
V. 03 22/10/2018 1 ©Velleman nv –
USER MANUAL
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal
of the device after its lifecycle could harm the environment. Do
not dispose of the unit (or batteries) as unsorted municipal
waste; it should be taken to a specialized company for recycling.
This device should be returned to your distributor or to a local
recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Perel! Please read the manual thoroughly before
bringing this device into service. If the device was damaged in transit, do not
install or use it and contact your dealer.
2. Safety Instructions
● This device can be used by children aged from 8 years and above, and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning the use of the device in a safe way and understand the hazards
involved. Children shall not play with the device. Cleaning and user
maintenance shall not be made by children without supervision. Indoor use ●
only. Keep this device away from rain, moisture, splashing and dripping
liquids Risk of electroshock when opening the cover. Touching live wires . ●
can cause life-threatening electroshocks. Familiarise yourself with the ●
functions of the device before actually using it. All modifications of the ●
device are forbidden for safety reasons. Damage caused by user modifications
to the device is not covered by the warranty. Damage caused by disregard ●
of certain guidelines in this manual is not covered by the warranty and the
dealer will not accept responsibility for any ensuing defects or problems.
● ● Keep this manual for future reference. Refer to the Velleman
® Service and
Quality Warranty on www.velleman.eu.
3. Overview
1. M button
5. SIM card slot
2. antenna
6. USB connector (firmware
3. GSM status LED
upgrade only)
4. power LED
7. temperature sensor slot
GSM status LED:
Slow blinking: no GSM signal
Normal blinking: GSM signal fixed
Fast blinking: send or receive SMS
4. Power Control Connector
input
output
Input: 110- 230 V~
L: live
N: negative
G: ground
Output: 110- 230 V~
L: live
N: negative
G: ground
12V: output and alarm sensor input
12V: constant 12 VDC output (max. 200 mA)
S1: wired sensor input 1, NO/NC type
S2: wired sensor input 2, NO/NC type
12V(C): controllable 12 VDC output (max. 200 mA) (only via SMS)
5. Start
● ● SIM card’s Connect the antenna to the power control. Deactivate the PIN
code using your cell phone. Install your SIM card (standard format) Make ●.
sure to insert it fully into the slot Connect the temperature sensor if . ●
desired. Connect the power input and output. Make sure to cut off the ●
power supply prior to connecting! Reconnect the power. The LED will light ●
within 3 to 5 seconds.
6. Registering a Phone Number
This power control accepts up to five phone numbers, i.e. one master number
and four auxiliary numbers The master number has full authorization to .
configure the devices. The auxiliary numbers can only be added by the
master number. All configurations are processed by sending an SMS to the
device’s SIM card. The SMS format is #code-1#code-2#.
Register the master number: # # 00
Add an auxiliary number: # #User-number# 06
Delete an auxiliary number: # #User-number# 15
Manually reset the device to delete the old master number if the device
replies [Master number already exists]. Hold the M button pressed for ten
seconds to return to the factory settings.
7. Free-Calling Control
A master or auxiliary number calling the SIM card number is able to switch
the 230 V power on or off for a few seconds.
Call to switch on/off the power output: #09#1#
When a user is calling, the switched on power will switch off and vice
versa.
Call to switch on/off the power output for a few seconds: #09#2#time#
Time parameters: 1-1800, i.e. duration 1-1800 seconds.
Switch off calling control function: #09#0#
8. Power On/Off
Any registered user can send an SMS to switch the 230 V power on/off.
Switch on power: #01#0#
Switch off power: 2#0# #0
9. Delay Control
Automatically switch the 230 V power on/off for a few minutes. Valid only for
the master number.
Switch on power for a few minutes: 2#0#time#0# #1
Switch off power for a few minutes: 2#0#time#1# #1
Time range: 1-720, i.e. duration 1-720 minutes.
Manually switch on/off the device to abort this function automatically.
10. Schedule Control
Automatically switch the 230 V power on/off according to the set schedule.
Valid only for the master number.
Set switch-on schedule: #20#0#day#start-time#end-time#
It will switch on the power at set time.
Day: one digit, see table.
value
day
value
day
0
Every day
5
Friday
1
Monday
6
Saturday
2
Tuesday
7
Sunday
3
Wednesday
8
Monday-Friday
4
Thursday
9
Weekend
Start-time and end-time: four digits (hhmm) in 24h-format.
Example: #20#0#0#2000#0800# means every day, power on at
20 08:00, power off at :00 the next day.
Activate schedule control function: #19#0#1#
Manually switch on/off the device to abort this function automatically.
Specyfikacje produktu
| Marka: | Perel |
| Kategoria: | Sprzęt pomiarowy |
| Model: | E300GSM |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Perel E300GSM, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Sprzęt pomiarowy Perel
2 Października 2024
25 Września 2024
25 Września 2024
5 Września 2024
5 Września 2024
4 Września 2024
2 Września 2024
1 Września 2024
1 Września 2024
31 Sierpnia 2024
Instrukcje Sprzęt pomiarowy
- Vimar
- Testo
- Homedics
- Danfoss
- Qualita
- Microlife
- H-Tronic
- Voltcraft
- Enda
- Kübler
- Lanaform
- CESYS
- ProfiCare
- VDO
- Tempo
Najnowsze instrukcje dla Sprzęt pomiarowy
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025