ENERGY CONSUMPTION METER 
ENERGY CONSUMPTION METER 
ENERGY CONSUMPTION METER 
ENERGY CONSUMPTION METER ENERGY CONSUMPTION METER   
   UK - 
UK - 
UK - 
UK - UK - 1 
PCF-605 
PCF-605 
PCF-605 
PCF-605 PCF-605 
Thank you for purchasing this Profile product. Please 
note: It is important that you read this manual before 
using the product. And be sure to save this manual for 
possible use later. 
Please note  
The Energy Meter must be charged before use. 
After 15 minutes, the LCD screen will be 
operational, but to fully charge the battery, the 
device must be plugged into the mains for at least 
12 hours. 
The Energy Meter is the easiest way for you to 
measure the energy costs of connected appliances. 
Technical data  
  Operating voltage: 230V AC (50/60 Hz) alternating 
current (AC) 
  Maximum power of connected appliances: 3680 W 
  Maximum current: 16A 
  Input/ Output: via earthed socket 
  Operating temperature: + 10 to +40° C 
  Energy display: 0 kWh to 999.9 kWh 
  Maximum registration time: 9999 hours 
  Only use indoors (IP20) 
Correct use 
The measurement range of the Energy Meter is 5W to 
3680W. Exact measurement of values below or above 
this range is not possible. Use outside this range can 
overload and damage the unit. 
  The Energy Meter was designed to monitor and 
measure electric appliances. 
  The Energy Meter is approved only for use with 
230V AC. 
  Only 230V AC, 50/60Hz electric appliances may be 
connected. 
  The maximum power of the connected loads may 
not exceed 3680W (maximum amperage 16A). 
  Use of the Energy Meter is only allowed indoors in 
dry environments. Use in the open air is strictly 
prohibited! 
  Always heed the instructions on the identification 
label located on the connected power cables. 
  Use other than that described above can result in 
damage to the product and the risk of short circuit, 
fire, electric shocks, etc. 
  The product as a whole may not be converted or 
modified. The safety instructions must be followed 
strictly. 
Safety instructions 
  The manufacturers accept no liability for damage to 
objects or persons that arises from incorrect use or 
noncompliance with the safety prescriptions. All 
damage claims resulting in such cases are void. 
  The Energy Meter may only be connected to 
regulated outlets (230V AC, 50/60Hz- 10/16A) with 
a ground. 
  The connected appliances may not use more than 
3680W (16A). 
  The operating temperature of the connected 
appliance must be between 10º and 40º. 
  High temperatures, especially when measuring high 
levels of electrical power, can result in overheating 
and damage to the Energy Meter. 
  Avoid use in extreme weather conditions and in the 
vicinity of inflammable gases, moisture and dust. 
  For safety reasons, the unit may never be operated 
in a wet or damp environment. 
  During cleaning or maintenance, disconnect each 
source of power from the Energy Meter. The battery 
and the LCD screen can retain a charge, even when 
the unit is disconnected from all sources of power. 
  Insert no metal parts or other objects in the Energy 
Meter. 
  If it is established that safe use is no longer 
possible, take the Energy Meter out of operation and 
ensure that it is not mistakenly put back into 
operation by someone else. If there is visible 
damage to the Energy Meter, it must be taken out of 
service immediately. 
Features 
  Display of current time (24-hour clock), day, energy 
consumption in Watts and billing rate. 
  Display of total time connected, energy consumed 
and the cost of energy consumed. 
  Display of total registered times, total time and 
percentages. 
  Programmable day and night rates. 
Configuration, connection and operation 
  The procedure for setting the time and the billing 
rate is the following: 
Setting the current time and day  
1. Simultaneously press the  “+” and ”-
“ buttons to enter the system 
configuration. The first setting is the 
current time. 
2. Use the “+” button to increase the 
value of the flashing position from 0 to 
9; use the “-“ button to decrease the value of the 
flashing position. 
3. Press the “MODE” button to move the next position. 
4. After setting the day, push the “MODE” button again 
– billing rate 1 for the system can now be configured. 
Setting billing rate 1 (day rate) 
1. Set the start time for billing rate 
1. For example day rate starts at 
7.00 a.m. 
2. Set rate 1. All values are 
introduced in quantities of eurocents. 
E.g. 1.00€ = 100cent 
3.  Use the “+” button to increase the value of the 
flashing position from 0 to 9; use the “-“ button to 
decrease the value of the flashing position. 
4. Press the “MODE” button to move to the next 
position. 
5. Press the “MODE” button - billing rate 2 for the 
system can now be configured. 
Specyfikacje produktu
| Marka: | Profile | 
| Kategoria: | inteligentny dom | 
| Model: | PCF-635 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Profile PCF-635, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje inteligentny dom Profile
                        
                         27 Czerwca 2024
                        
                    
                                                            
                        
                         27 Czerwca 2024
                        
                    
                                                            Instrukcje inteligentny dom
- KlikaanKlikuit
- Trevi
- Niceboy
- Nanoleaf
- Logitech
- Aqara
- Adurosmart
- LevelOne
- Lenovo
- Sommer
- Klarstein
- Theben
- Osram
- Gigaset
- BTicino
Najnowsze instrukcje dla inteligentny dom
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         27 Marca 2025
                        
                    
                                                            
                        
                         18 Marca 2025
                        
                    
                                                            
                        
                         18 Marca 2025
                        
                    
                                                            
                        
                         12 Marca 2025
                        
                    
                                                            
                        
                         25 Lutego 2025
                        
                    
                                                            
                        
                         19 Lutego 2025
                        
                    
                                                            
                        
                         14 Lutego 2025