2 Gas Conversion Manual for Condensing Tankless Water Heaters
This conversion kit shall be installed by a qualified service
agency in accordance with the manufacturers instructions and
all applicable codes and requirements of the authority having jurisdiction. The
information in these instructions must be followed to minimize the risk of fire or
explosion or to prevent property damage, personal injury or death. The qualified
service agency is responsible for the proper installation of this kit. The installation is
not proper and complete until the operation of the converted appliance is checked
as specified in the manufacturers instructions supplied with the kit.
WARNING
Le kit de conversion doit être installé par un
organisme de service qualifié, conformément aux
instructions du fabricant, à la réglementation et aux exigences applicables de
lautorité compétente. Les instructions de cette notice doivent être suivies afin de
réduire au minimum le risque dincendie ou dexplosion, de dommages matériels,
de blessure ou de mort. Lorganisme de service qualifié est responsable de
linstallation appropriée de ce kit. Linstallation nest pas correcte ni complète tant
que le fonctionnement de lappareil converti na pas été vérifié, conformément aux
instructions du fabricant du kit.
This manual applies to the following tankless water heater models:
Ce manuel sapplique aux modèles de chauffe-eau instantané suivants:
Residential Models Modèles résidentiels
RX199i
RX180i
RX160i
RX130i
RXP199i
RXP160i
(REU-NB3237FF-US)
(REU-NB2934FF-US)
(REU-NB2530FF-US)
(REU-NB2024FF-US)
(REU-NBP3237FF-US)
(REU-NBP2530FF-US)
Residential models are certified for installation in
mobile homes.
Les modèles résidentiels sont certifiés pour
linstallation dans les maisons mobiles.
Commercial Models Modèles commerciaux
CX199i
CX160i
CXP199i
CXP160i
(REU-NB3237FFC-US)
(REU-NB2530FFC-US)
(REU-NBP3237FFC-US)
(REU-NBP2530FFC-US)
Commercial models are not certified for
installation in mobile homes.
Les modèles commerciaux ne sont pas certifiés
pour linstallation dans des maisons mobiles.
1. Safety ..................................................... 3
1.1 Safety Symbols ................................ 3
2. Technical Data ...................................... 4
3. Parts List ............................................... 4
4. Gas Conversion Steps ......................... 5
4.1 Adjust Parameter Settings ............... 5
4.2 Gas Operating Instructions .............. 7
4.3 Check Operation .............................. 8
1. Sécurité .................................................. 3
1.1 Symboles de sécuri ..................... 3
2. Informations techniques ................... 11
3. Nomenclature ..................................... 11
4. Instructions de conversion de gaz .. 12
4.1 Réglage des paramètres .............. 12
4.2 Instructions relatives au gaz ......... 14
4.3 Vérification du fonctionnement ..... 15
Gas Conversion Manual for Condensing Tankless Water Heaters 3
For installations in Canada, the conversion shall be carried out in accordance with the requirements
of the provincial authorities having jurisdiction and in accordance with the requirements of the
CSA-B149.1, Natural Gas and Propane Installation Code.
Si lappareil est installé au Canada, la conversion doit être effectuée conformément aux exigences
des autorités provinciales compétentes et conformément aux exigences de la norme CSA-B149.1,
Code dinstallation du gaz naturel et du propane.
The appliance must be installed in accordance with:
Lappareil doit être installé conformément aux normes et réglementations suivantes:
Local codes or, in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1/
NFPA 54 and/or CSA B149.1, Natural Gas and Propane Installation Code.
La réglementation locale ou, en son absence, au National Fuel Gas Code, ANSI Z223.1/
NFPA 54, et/ou au code dinstallation du gaz naturel et du propane CSA B149.1.
The Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 or CSA
Z240 MH Series, Manufactured Homes.
La norme Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 ou
la norme CSA Z240 série MH, maisons préfabriquées.
Indicates an imminently hazardous
situation which, if not avoided, will result in
personal injury or death.
Safety alert symbol. Alerts you to
potential hazards that can kill or
hurt you and others.
Indicates a potentially hazardous situation
which, if not avoided, could result in
personal injury or death.
Indique une situation potentiellement
dangereuse qui, si elle nest pas évitée,
peut provoquer des blessures graves voire
mortelles.
Indicates a potentially hazardous situation
which, if not avoided, could result in minor
or moderate injury. It may also be used to
alert against unsafe practices.
WARNING
CAUTION
Indique une situation dangereuse
imminente qui, si elle nest pas évitée, peut
entraîner des blessures graves voire
mortelles.
Symbole dalerte. Indique un danger
potentiel pouvant conduire à des
blessures corporelles, voire mortelles,
pour lutilisateur et des tiers.
Indique une situation potentiellement
dangereuse qui, si elle nest pas prévenue,
peut provoquer des blessures légères ou
modérées. Ce terme peut également servir
à prévenir contre des pratiques
dangereuses.
AVERTISSEMENT
ATTENTION
DANGER


Specyfikacje produktu

Marka: Rinnai
Kategoria: kocioł i podgrzewacz wody
Model: RX130iN

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Rinnai RX130iN, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje kocioł i podgrzewacz wody Rinnai

Instrukcje kocioł i podgrzewacz wody

Najnowsze instrukcje dla kocioł i podgrzewacz wody