Instrukcja obs艂ugi Sauter CE HSP
Sauter
Niesklasyfikowane
CE HSP
Przeczytaj poni偶ej 馃摉 instrukcj臋 obs艂ugi w j臋zyku polskim dla Sauter CE HSP (13 stron) w kategorii Niesklasyfikowane. Ta instrukcja by艂a pomocna dla 8 os贸b i zosta艂a oceniona przez 4.5 u偶ytkownik贸w na 艣rednio 3.7 gwiazdek
Strona 1/13

Sauter GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel.: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.sauter.eu
Instruction manual
SAUTER CE HS
V. 1.0
10/2019
GB
CE_HS-BA-e-1901.docx

2 CE_HS-BA-e-1901.docx
GB
SAUTER CE HS
V. 1.0 10/2019
Instruction manual
Summarize:
1 IMPORTANT SAFETY INFORMATION .......................................................... 4
2 WARNING! ELECTRICAL SHOCK HAZARD ................................................ 5
3 Load cell / power connection ........................................................................ 6
3.1 CE HSA ...................................................................................................................................... 6
3.2 CE HSE ...................................................................................................................................... 6
3.3 CE HSP ...................................................................................................................................... 7
3.4 CE HSR ...................................................................................................................................... 7
4 Indication of Display ...................................................................................... 8
5 Explanation of front keys .............................................................................. 9
6 First use of indicator ................................................................................... 10
6.1 Configuration menu structure ............................................................................................... 10
6.2 Weigher settings ..................................................................................................................... 11
6.3 Adjustment .............................................................................................................................. 14
6.4 First use by using PI Mach II software ................................................................................. 17
6.5 Communication ...................................................................................................................... 20
6.5.1 CE HSE (Ethernet) ................................................................................................................... 20
6.5.2 CE HSP (Profibus) .................................................................................................................... 20
6.5.3 CE HSR (serial RS232) ............................................................................................................ 21
6.6 Finish quick setup .................................................................................................................. 21
7 Main Menu - Full setup ................................................................................ 22
7.1 Setpoints ................................................................................................................................. 22
7.2 TAC code (Traceable Acces Code). ...................................................................................... 23
7.3 CAL code (Calibration counter). ........................................................................................... 24
8 Configuration Menu ..................................................................................... 26
8.1 setpoint function settings (not for CE HSA) ........................................................................ 26
8.2 ACn setpoint action settings (not for CE HSA) ................................................................... 27
8.3 dAC Analog output settings (only for CE HSA) .................................................................. 28
8.4 Local bus communication settings (RS485) ........................................................................ 31
8.5 Ethernet settings (CE HSE only) ........................................................................................... 32
8.6 Profibus settings (CE HSP only) ........................................................................................... 36
8.7 RS232 Port settings (CE HSR only) ...................................................................................... 37
8.8 RS422 Port settings (CE HSR only) ...................................................................................... 40
8.9 Indicator settings .................................................................................................................... 43
8.10 Multi range/interval settings .................................................................................................. 48
8.11 Filter settings .......................................................................................................................... 51
8.12 Digital filter settings ............................................................................................................... 54
8.13 Pre-calibration settings.......................................................................................................... 56
8.14 Calibration settings ................................................................................................................ 58

CE_HS-BA-e-1901.docx 3
8.15 Theoretic calibration .............................................................................................................. 61
8.16 Geographic calibration .......................................................................................................... 64
8.17 Date and time configuration (CE HSR only) ........................................................................ 66
8.18 Recall ....................................................................................................................................... 67
8.19 Firmware update ..................................................................................................................... 68
9 Error Codes .................................................................................................. 71
10 Profibus Protocol Description .................................................................... 73
11 Standard Factory Settings .......................................................................... 74
12 Appendix I .................................................................................................... 77
13 Certificate of Compliance ............................................................................ 78
Specyfikacje produktu
Marka: | Sauter |
Kategoria: | Niesklasyfikowane |
Model: | CE HSP |
Potrzebujesz pomocy?
Je艣li potrzebujesz pomocy z Sauter CE HSP, zadaj pytanie poni偶ej, a inni u偶ytkownicy Ci odpowiedz膮
Instrukcje Niesklasyfikowane Sauter
8 Stycznia 2025
8 Stycznia 2025
8 Stycznia 2025
12 Wrze艣nia 2024
6 Wrze艣nia 2024
5 Wrze艣nia 2024
5 Wrze艣nia 2024
2 Wrze艣nia 2024
2 Wrze艣nia 2024
2 Wrze艣nia 2024
Instrukcje Niesklasyfikowane
- Niesklasyfikowane VintageView
- Niesklasyfikowane MaxCom
- Niesklasyfikowane Devolo
- Niesklasyfikowane Metabo
- Niesklasyfikowane Tesseract Modular
- Niesklasyfikowane OzCharge
- Niesklasyfikowane Blackstar
- Niesklasyfikowane AJ.BA
- Niesklasyfikowane SolarEdge
- Niesklasyfikowane Angler
- Niesklasyfikowane Kupper
- Niesklasyfikowane Fontiso
- Niesklasyfikowane Clean Paper
- Niesklasyfikowane Banoch
- Niesklasyfikowane Majority
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025