SITOP UPS1100 
SITOP UPS1100 
SITOP UPS1100 
SITOP UPS1100 SITOP UPS1100 
Batteriemodul 1,2 Ah  
Batteriemodul 1,2 Ah  
Batteriemodul 1,2 Ah  
Batteriemodul 1,2 Ah  Batteriemodul 1,2 Ah  
6EP4131-0GB00-0AY0 
6EP4131-0GB00-0AY0 
6EP4131-0GB00-0AY0 
6EP4131-0GB00-0AY0 6EP4131-0GB00-0AY0 
Batteriemodul 3,2 Ah  
Batteriemodul 3,2 Ah  
Batteriemodul 3,2 Ah  
Batteriemodul 3,2 Ah  Batteriemodul 3,2 Ah  
6EP4133-0GB00-0AY0 
6EP4133-0GB00-0AY0 
6EP4133-0GB00-0AY0 
6EP4133-0GB00-0AY0 6EP4133-0GB00-0AY0 
Batteriemodul 7 Ah  
Batteriemodul 7 Ah  
Batteriemodul 7 Ah  
Batteriemodul 7 Ah  Batteriemodul 7 Ah  
6EP4134-0GB00-0AY0 
6EP4134-0GB00-0AY0 
6EP4134-0GB00-0AY0 
6EP4134-0GB00-0AY0 6EP4134-0GB00-0AY0 
Operating Instructions (compact) 
Bild 1: Ansicht Geräte 
Figure 1: View of the devices 
Figure 1: Vue des appareils 
Figura 1: Vista degli apparecchi 
Figura 1: Vista de aparatos 
Bild 2: Montage 1,2 Ah 
Figure 2: Mounting 1.2 Ah 
Figure 2: Montage 1,2 Ah 
Figura 2: Montaggio 1,2 Ah 
Figura 2: Montaje 1,2 Ah 
ENGLISH 
ENGLISH 
ENGLISH 
ENGLISH ENGLISH 
Description 
Description 
Description 
Description Description 
The 24 V/1.2 Ah, 3.2 Ah or 7 Ah battery 
module has 2x maintenance-free, sealed 
lead AGM rechargeable batteries as well 
as terminals for the connecting cables to 
the uninterruptible power supply SITOP 
UPS1600. 
degree of protection IP20 according to 
EN 60529 
See Figure 1 View of the devices (Page 1)
Safety notes
Safety notes
Safety notes
Safety notesSafety notes 
NOTICE 
NOTICE 
NOTICE 
NOTICE NOTICE 
The fuses should only be inserted in the 
fuse holder when commissioning the 
device. 
When replacing the rechargeable 
batteries, always use batteries with the 
same batch number. (approximately the 
same charge state). 
The rechargeable batteries must be 
disposed of, discharged according to the 
applicable regulations. 
When storing, installing and operating 
the buffer batteries, the regulations of 
VDE 0510 Part 2 / EN 50272-2 or the 
applicable national regulations must be 
complied with. 
It must be ensured that the battery 
location is suitably ventilated. 
Location of the battery module: In the 
lower part of the control cabinet or at the 
coolest location in the control cabinet. 
Only qualified personnel are allowed to 
install the device/system and set it into 
operation. 
Assembling 
Assembling 
Assembling 
Assembling Assembling 
Direct wall mounting 
or 
DIN EN 60715-TH35-15/7,5 for 1.2 Ah 
or  
DIN EN 60715-TH35-15 for 3.2 Ah 
The device must be mounted in such a 
way that the input and output terminals 
are at the bottom. 
A clearance of at least 50 mm must be 
maintained above and below the device.
See Figure 2 Mounti 1) ng 1.2 Ah (Page 
See Figure 3 Mounti 2) ng 3.2 Ah (Page 
See Figure 4 Mounti 2) ng 7 Ah (Page 
 
Bild 3: Montage 3,2 Ah 
Figure 3: Mounting 3.2 Ah 
Figure 3: Montage 3,2 Ah 
Figura 3: Montaggio 3,2 Ah 
Figura 3: Montaje 3,2 Ah 
 
Bild 4: Montage 7 Ah 
Figure 4: Mounting 7 Ah 
Figure 4: Montage 7 Ah 
Figura 4: Montaggio 7 Ah 
Figura 4: Montaje 7 Ah 
Bild 5: Input/Output 1,2 Ah 
Figure 5: Input/output 1.2 Ah 
Figure 5: Entrée/sortie 1,2 Ah 
Figura 5: Input/Output 1,2 Ah 
Figura 5: Entrada/salida 1,2 Ah 
Connecting 
Connecting 
Connecting 
Connecting Connecting 
For installation of the devices, the 
relevant country-specific regulations 
must be observed. 
See Figure 5 Input/output 1.2 Ah (Page 2)
See Figure 6 Input/output 7 Ah (Page 3) 
See Figure 7 Terminal data 1.2 Ah/3.2 Ah 
(Page 3) 
See Figure 8 Terminal data 7 Ah (Page 3)
Structure 
Structure 
Structure 
Structure Structure 
①DC input X1
②Signal terminal X2
③Fuses F1/F2 (F2 only for 7 Ah)
④Signaling (LED)
⑥Screws for battery replacement
(Torx T10)
See Figure 5 Input/output 1.2 Ah (Page 2)
See Figure 6 Input/output 7 Ah (Page 3) 
Battery 
Battery 
Battery 
Battery Battery 
2x maintenance-free lead AGM 
rechargeable batteries 
12 V/1.2 Ah: Type: YUASA NP1.2-12  
12 V/3.2 Ah: Type: YUASA NP3.2-12 or 
B.B.Battery BP3.6-12 
12 V/7 Ah: Type: YUASA NP7-12 or 
B.B.Battery BP7-12 
Battery replacement 
● Remove the fuse
● Release the screws  ⑥, open the
cover
● on for at least 2sPress the reset butt
(LED flashes)
● Replacing the battery
● on for at least 2sPress the reset butt
● Close the cover (screw)
● Insert the fuse
See Figure 9 Reset (Page 3) 
See Figure 10 Wiring schematic 
(Page 4) 
The self-discharge rates of the 
rechargeable batteries is approx. 
3%/month for a temperature of 20 °C. 
This value is temperature dependent, 
and for an increasing temperature, 
becomes more unfavorable and for a 
decreasing temperature, more favorable.
Specyfikacje produktu
| Marka: | Siemens | 
| Kategoria: | UPS | 
| Model: | SITOP UPS1100 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Siemens SITOP UPS1100, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje UPS Siemens
                        
                         31 Sierpnia 2024
                        
                    
                                                            
                        
                         14 Sierpnia 2024
                        
                    
                                                            Instrukcje UPS
- Online USV
- Block
- Tripp Lite
- Bxterra
- Avocent
- LevelOne
- HP
- AEG
- GYS
- CyberPower
- V7
- Vanson
- Hikvision
- Lenovo
- LC-Power
Najnowsze instrukcje dla UPS
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         30 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         27 Marca 2025