Instrukcja obsługi Supermicro SuperBlade SBI-8149P-T8N
                    Supermicro
                    
                    serwer
                    
                    SuperBlade SBI-8149P-T8N
                
                                
    Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Supermicro SuperBlade SBI-8149P-T8N (1 stron) w kategorii serwer. Ta instrukcja była pomocna dla 25 osób i została oceniona przez 13 użytkowników na średnio 4.9 gwiazdek
                        Strona 1/1
                    
                    
                    
SuperBlade SBI-8149P-C4N/T8N Blade Module Quick Reference Guide
Memory Support
 http://www.supermicro.com MNL-2089-QRG Rev 1.0
Board Layout
Supports up to 6 TB of RDIMM/3DS LRDIMM DDR4 2666 MHz speed and 8 GB, 16 GB, 32 GB, 64 GB and 128 GB size 
SDRAM memory in forty-eight (48) 288-pin DIMM sockets for each node. 
See https://www.supermicro.com/support/resources/memory/X11_memory_config_guide.pdf for details.
The Processor Heatsink Module (PHM) contains 1) a heatsink, 
2) a narrow processor clip, and 3) the SKX(-F) processor.
1. Heatsink
2. Narrow Processor Clip 
3. SKK Processor
Bottom View
Attaching the Processor to the Narrow Processor Clip to Create 
the Processor Package Assembly
To properly install the CPU into the narrow processor clip, please follow 
the steps below.
1. Locate pin 1 (notch A), which is the triangle located on the top of the 
narrow processor clip. Also locate notch B and notch C on the processor clip.
2. Locate pin 1 (notch A), which is the triangle on the substrate of the CPU. 
Also, locate notch B and notch C on the CPU as shown below.
3. Align pin 1 (the triangle on the substrate) of the CPU with pin 1 (the triangle) 
of the narrow processor clip. Once they are aligned, carefully insert the CPU
into the processor clip by sliding notch B of the CPU into notch B of the 
processor clip, and sliding notch C of the CPU into notch C of the processor clip.
4. Examine all corners of the CPU to ensure that it is properly seated on the 
processor clip. Once the CPU is securely attached to the processor clip, the 
processor package assembly is created.
Note: Please exercise extreme caution when handling the CPU. Do not touch the 
CPU LGA-lands to avoid damaging the LGA-lands or the CPU. Be sure to wear 
ESD gloves when handling components. 
Attaching the Processor Package Assembly to the Heatsink to Form 
the Processor Heatsink Module (PHM)
After you have made a processor package assembly by following the instructions on the 
previous page, please follow the steps below to mount the processor package assembly 
onto the heatsink to create the Processor Heatsink Module (PHM). 
1. Locate "1" on the heatsink label and the triangular corner next to it on the heatsink. 
With your index finger pressing against the screw at this triangular corner, carefully hold 
and turn the heatsink upside down with the thermal-grease side facing up. Remove the 
protective thermal film if present, and apply the proper amount of the thermal grease as 
needed. (Skip this step if you have a new heatsink because the necessary thermal 
grease is pre-applied in the factory.)
2. Holding the processor package assembly at the center edge, turn it upside down. With 
the thermal-grease side facing up, locate the hollow triangle located at the corner of the 
processor carrier assembly ("a" in the graphic). Note a larger hole and plastic mounting 
clicks located next to the hollow triangle. Also locate another set of mounting clicks and a 
larger hole at the diagonal corner of the same (reverse) side of the processor carrier 
assembly ("b" in the graphic).
3. With the back of heatsink and the reverse side of the processor package assembly 
facing up, align the triangular corner on the heatsink ("A" in the graphic) against the 
mounting clips next to the hollow triangle ("a") on the processor package assembly.
4. Also align the triangular corner ("B") at the diagonal side of the heatsink with the 
corresponding clips on the processor package assembly ("b"). 
5. Once the mounting clips on the processor package assembly are properly aligned with 
the corresponding holes on the back of heatsink, securely attach the heatsink to the 
processor package assembly by snapping the mounting clips at the proper places on the 
heatsink to create the processor heatsink module (PHM). 
Preparing the CPU Socket for Installation
This motherboard comes with the CPU socket pre-assembled in the factory. The CPU 
socket contains 1) a dust cover, 2) a socket bracket, 3) the CPU (P0) socket, and 4) a 
back plate. These components are pre-installed on the motherboard before shipping. 
CPU Socket w/Dust Cover On
Removing the Dust Cover from the CPU Socket
Remove the dust cover from the CPU socket, exposing the SKX socket and socket pins 
as shown on the illustration below. 
Note: Do not touch the socket pins to avoid damaging them, causing the CPU to 
malfunction.
Installing the Processor Heatsink Module (PHM)
Once you have assembled the processor heatsink module (PHM) by following the 
instructions listed on page 29 or page 30, you are ready to install the processor 
heatsink module (PHM) into the CPU socket on the motherboard. To install the PHM 
into the CPU socket, follow the instructions below.
1. Locate the triangle (pin 1) on the CPU socket, and locate the triangle (pin 1) at the 
corner of the PHM that is closest to "1." (If you have difficulty locating pin 1 of the 
PHM, turn the PHM upside down. With the LGA-lands side facing up, you will note the 
hollow triangle located next to a screw at the corner. Turn the PHM right side up, and 
you will see a triangle marked on the processor clip at the same corner of hollow 
triangle.)
2. Carefully align pin 1 (the triangle) on the PHM against pin 1 (the triangle) on the 
CPU socket.
3. Once they are properly aligned, insert the two diagonal oval holes on the heatsink 
into the guiding posts.
4. Using a T30 Torx-bit screwdriver, install four screws into the mounting holes on the 
socket to securely attach the PHM onto the motherboard starting with the screw 
marked "1" (in the sequence of 1, 2, 3, and 4).
Do not use excessive force when tightening the screws to avoid damaging the 
LGA-lands and the processor.
Removing the Processor Heatsink Module (PHM) from the Motherboard
Before removing the processor heatsink module (PHM), unplug power cord from the 
power outlet.
1. Using a T30 Torx-bit screwdriver, turn the screws on the PHM counterclockwise to 
loosen them from the socket, starting with screw marked #4 (in the sequence of 4, 3, 2, 
1).
2. After all four screws are removed, wiggle the PHM gently and pull it up to remove it 
from the socket.
Note: To properly remove the processor heatsink module, be sure to loosen and remove 
the screws on the PHM in the sequence of 4, 3, 2, 1 as shown below.
DDR4 Memory Support for Two Slots per Channel
Type    Ranks     DIMM Capacity (GB)                  Speed (MT/s) 
    Per DIMM             Two Slots per Channel 
    and Data          One DIMM per Channel     Two DIMMs per Channel 
    Width  4 Gb  8 Gb    1.2 Volts    1.2 Volts
RDIMM    SRx4  8 GB  16 GB       2666       2666
    SRx8  4 GB  8 GB       2666       2666
    DRx8  8 GB  16 GB       2666       2666
    DRx4  16 GB  32 GB       2666       2666
RDIMM 3Ds    QRX4  N/A  2H-64GB       2666       2666
    8RX4  N/A  4H-128GB       2666       2666
LRDIMM    QRx4  32 GB  64 GB       2666       2666
LRDIMM 3Ds  QRX4  N/A  2H-64GB       2666       2666
    8Rx4  N/A  4H-128 GB       2666       2666
SBI-8149P-C4N/T8N Module Layout
Item Description
1      CPUs installed (four total)
2      Front housing for 2.5" SATA3/SSD/NVMe hard drive bays (four (C4N) or eight (T8N) total)
3      DIMM slots (48 total)
4      Power and Logic connectors to backplane
5      InfiniBand, Omni-path or NVMe/SATA Mezzanine Card
6      NVMe/SATA Mezzanine Card
7      Universal Serial Bus (3.0 USB) Ports
8      SATA DOM Port
9      9-pin TPM Connector
10    Broadcom 3108 Mezzanine Card
Key Parameters for DIMM Configurations
Parameters      Possible Values
Number of Channels    1, 2, 3, 4, 5 or 6
Number of DIMMs per Channel  1DPC (1 DIMM Per Channel) or 2DPC (2 DIMMs Per Channel)
DIMM Type      RDIMM (w/ECC), 3DS RDIMM, LRDIMM or 3DS-LRDIMM
DIMM Construction    Non-3DS RDIMM Raw Cards: A/B (2RX4), C (1RX4), D (1RX8) or E (2RX8)
      3DS RDIMM Raw Cards: A/B (4RX4)
      Non-3DS LRDIMM Raw Cards: D/E (4RX4)
      3DS LRDIMM Raw Cards: A/B (8RX4)
Mixing of DIMM Types within a Channel
DIMM Types   RDIMM    LRDIMM    3DS LRDIMM
RDIMM    Allowed    Not Allowed    Not Allowed
LRDIMM    Not Allowed    Allowed    Not Allowed
3DS LRDIMM  Not Allowed    Not Allowed    Allowed
Control Panel
CPU and Heat Sink Installation 
Caution
          SAFETY INFORMATION
IMPORTANT: See installation instructions and safety warning before 
connecting system to power supply.
http://www.supermicro.com/about/policies/safety_information.cfm
          WARNING:
To reduce risk of electric shock/damage to equipment, disconnect power 
from server by disconnecting all power cords from electrical outlets.
If any CPU socket empty, install protective plastic CPU cap
          WARNING:
Always be sure all power supplies for this system have the same power 
output. If mixed power supplies are installed, the system will not operate.
For more information go to: http://www.supermicro.com/support
!
!
!
Installing the Processor
Enclosure Requirements
Enclosure Requirements
The SBI-8149P-C4N/T8N blade module requires one of the following enclosures to run in:
SBE-820C-822    SBE-820C-622    SBE-820C-422   
SBE-820J-822    SBE-820J-622    SBE-820J-422
See the Supermicro webstite for details on enclosures at: 
https://www.supermicro.com/en/products/superblade/enclosure 
Note: The SBI-8149P-C4N/T8N blade module also requires one or more power supplies in the 
enclosure to run the blade module. Available SuperBlade power supplies can be found on 
the Supermicro website at https://www.supermicro.com/products/SuperBlade/powersupply/.
7
4
33
1
Blade Control Panel
Item Function State Description
1 Power Button N/A
2 Power LED Green Indicates power status “On”
Solid Orange
Flashing Orange Flashing Orange: Indicates node is not ready or not enough power to turn on 
3 KVM/UID LED Blue Indicates KVM being utilized on blade unit
Flashing Blue Indicates UID activated on blade module
4 Network/IB LED Flashing Green Indicates network activity over LAN
Flashing Orange Indicates network activity
5
6 
System Fault LED
KVM Connector
Red
N/A
Indicates a memory error, overheat, VGA error or any error 
that prevents booting
Connector for SUV/KVM cable
Indicates power status “Off” (with power cables plugged in)
Turns blade module on and off
5
22
10
1
2345
6
8
6
9
3 3
33 3 3
1
1 1
Specyfikacje produktu
| Marka: | Supermicro | 
| Kategoria: | serwer | 
| Model: | SuperBlade SBI-8149P-T8N | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Supermicro SuperBlade SBI-8149P-T8N, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje serwer Supermicro
                        
                         30 Stycznia 2025
                        
                    
                                                            
                        
                         11 Stycznia 2025
                        
                    
                                                            
                        
                         11 Stycznia 2025
                        
                    
                                                            
                        
                         8 Stycznia 2025
                        
                    
                                                            
                        
                         28 Grudnia 2024
                        
                    
                                                            
                        
                         28 Grudnia 2024
                        
                    
                                                            
                        
                         24 Października 2024
                        
                    
                                                            
                        
                         8 Października 2024
                        
                    
                                                            
                        
                         8 Października 2024
                        
                    
                                                            
                        
                         8 Października 2024
                        
                    
                                                            Instrukcje serwer
- Dell
- LaCie
- Monacor
- Western Digital
- Moxa
- Toshiba
- Areca
- Sitecom
- AVerMedia
- EXSYS
- Veritas
- Asustor
- Digitus
- Seagate
- Rocstor
Najnowsze instrukcje dla serwer
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         10 Marca 2025
                        
                    
                                                            
                        
                         10 Marca 2025
                        
                    
                                                            
                        
                         10 Marca 2025