1. GENERAL DESCRIPTION
The ZM-9003 is a remote control switch panel with 4 interlocking selection switches and 2
momentary switches. Connecting it to the 9000 Series amplifier's control input terminal permits
various controls such as BGM source selection and the sound volume adjustment.
It can be mounted in an American standard 2-gang electrical box in a wall.
2. NOMENCLATURE AND FUNCTIONS
[Front] [Side] [Rear]
12
3
1. Interlocking selection switches [1 – 4]
Activate the function assigned to them when pressed.
2. Momentary switches [5, 6]
Activate the function assigned to them when pressed.
3. Control output terminal [1 – 6, E]
Connect this terminal to the 9000 Series amplifier's control input terminal.
Use a cable with 250 Ωor less line resistance (per line) for this connection.
Avoid installation of this cable and power cables in the same conduit. Separate piping.
3. CONNECTIONS
Up to 2 ZM-9003 units can be connected to the 9000 Series amplifier.
One C-001T Control I/O Expansion Module is required for connection.
Connect the ZM-9003 to each control input terminal of the C-001T and 9000 Series amplifier as
shown below.
Function assignment to the interlocking selection switches or momentary switches is performed at
the 9000 Series amplifier. For the method, refer to the instruction manual supplied with the 9000
Series amplifier.
E
E
4
4
3
3
1
2
2
1
VOL2
REMT
VOL1
REMT
OUT
IN
I/O
CTRL
E
IN
E
IN
E
E
4
4
3
3
1
2
2
1
VOL2
REMT
VOL1
REMT
OUT
IN
I/O
CTRL
E
IN
E
IN
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
E
OUT IN
1
2
3
4
5
6
7
8
E
1
2
3
4
5
6
E
9000 Series amplifier
(Control-I/O connection terminal)
(Control output terminal)
4 interlocking switches
ZM-9003
(Control output terminal)
4 interlocking switches
ZM-9003
C-001T
(Control input/output terminal)
9000 Series amplifier
OUT IN
1
2
3
4
5
6
7
8
E
C-001T


Specyfikacje produktu

Marka: TOA
Kategoria: Kontroler
Model: ZM-9003

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z TOA ZM-9003, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Kontroler TOA

TOA

TOA ZM-9003 Instrukcja

15 Września 2024
TOA

TOA ZM-9012 Instrukcja

4 Września 2024
TOA

TOA WP-700-AM Instrukcja

31 Sierpnia 2024
TOA

TOA AT-100 Instrukcja

27 Sierpnia 2024
TOA

TOA AT-100EMG Instrukcja

23 Sierpnia 2024
TOA

TOA ZM-9013 Instrukcja

19 Sierpnia 2024
TOA

TOA AT-025 Instrukcja

14 Sierpnia 2024
TOA

TOA AN9001 Instrukcja

13 Sierpnia 2024
TOA

TOA SS-9001PS Instrukcja

8 Sierpnia 2024

Instrukcje Kontroler

Najnowsze instrukcje dla Kontroler