Strona 1/7

Series
TMS 9XX SE A-EU
TMS 9XX SE P-EU
Single, w/PSU and EU Mains plug, 8-32 out, active TER
Single, w/PSU and EU Mains plug, 8-32 out, passive TER
TMS 9XX SE P-R
Single, no PSU, for SAT receiver DC sourcing, 8-32 out, passive TER
TMS 9XX CE A-EU
Cascade, for external PSU, 8-32 out, active TER
TMS 9XX CE P-EU
Cascade, for external PSU, 8-32 out, passive TER
Language
EN
Version: 9.2016.A
User Guide
TMS 9XX SE/CE Euro Line Multiswitch Series

EN
2
Triax Euro Line TMS 9XX SE/CE Multiswitch
The Triax Euro Line Multiswitch Range is a very high quality range of Multiswitches for single or cascade SAT-IF
(satellite) distribution networks with a need for RF loop-through. Available in both active and passive variants for RF
loop-through the range offers a perfect selection to use for both terrestrial aerial reception signals (A-active), as well
as a full CATV signal including DOCSIS support (P-passive). NOTE, DOCSIS limited by SAT-IF that occupies 950-
2150MHz.
The Euro Line Series is Made in Europe, and fully meets the EN 50083-3 Class A shielding requirements.
The purpose of this guide is to enable the successful installation and use of the TMS 9XX Multiswitch series.
The TMS 9XX Series (Two satellite positions):
TMS 9XX SE P-EU = Stand-alone unit, terrestrial passive, built-in PSU with EU Mains plug.
TMS 9XX SE A-EU = Stand-alone unit, terrestrial active, built-in PSU with EU Mains plug.
TMS 9XX SE P-R = Stand-alone unit, terrestrial passive. No PSU.
Power is sourced from the SAT-Receivers. Optionally an external PSU can be
added. This Version has no T-Active option to avoid too much power
consumption from connected SAT-receiver(s).
TMS 9XX CE P = Cascaded output unit, terrestrial passive, for external PSU.
TMS 9XX CE A = Cascaded output unit, terrestrial active, for external PSU.
NOTE: The TMS 9XX Range uses two Quattro LNBs each receiving from one orbital Satellite position.
XX are placeholder for individual units with 08, 12, 16, 24 or 32 user/subscriber outputs.
Please refer to Triax.com for Euro Series Multiswitch products for reception of 1, 3 and 4 SAT positions
Security
During installation please observe the requirements set forth in the EU safety standards EN 60065 and
50083-1 as well as local requirements and standards for SAT-IF and RF SMATV-installations.
Exercise care and good practise when mounting coaxial connectors (F-connectors) on the cables to
avoid short circuits and unnecessary emission of noise and disturbance of neighbouring installations.
Only perform multi switch installation jobs while mains plug of all power supplies are disconnected.
Make sure no short circuits are present on the distribution cables before applying mains power to the
multi switch installation and Satellite Receivers. Short circuits may overload, overheat and harm Power
Supplies and Satellite Receivers that are attempting to supply an excessive amount of current.
Check the rating labels of any attached power supply and make sure the local Mains Voltage you
connect it to never exceeds those ratings. Failure to observe this and act accordingly may compromise
the security and safety of the whole system and expose you and everyone attached to the installation to
damage, fire and electric shock.
Make sure the ambient temperature at the installation site never exceeds the temperature limits for the
product installed. If required you must arrange for suitable temperature conditioning. Failure to observe
this and act accordingly may compromise the performance, security and safety of the whole system and
expose you and everyone attached to the installation to damage, fire and electric shock.
A multi switch installation should be earthed. An earth screw is available on the multi switch unit.
The manufacturer is not responsible for damage or system failures caused by Installers ignoring the
above safety measures.
Installation:
First rule in any Multiswitch installation are: NEVER use a too small size satellite Dish, and
NEVER use the compromise of a dual mount LNB for a multi satellite position reception on one Dish.

3
Correct Dish size ensures sufficient reserves in bad weather and the best possible C/N for the rest of the
installation. Making compromises here CANNOT be fixed later in the network by adding Amplifiers!
A High Gain LNB only gives more Signal Level, but not Signal Quality. That only comes from Dish Size!
Mount the multi switch only indoor on a vertical dry surface using the available screwholes and ‘feets’.
Make sure that no supply voltage is available on the connection cables during installation.
(Temporarily turn off satellite receivers and/or their LNB supply).
Mount suitable F-connectors on the coax cable going to the satellite receivers and connect them
individually to a multi switch subscriber output (8 to 32 outputs dependent on type). Recommended
maximum cable length from switch to receiver is typically 25-35 meters depending upon cable
type/quality and satellite receiver. Far longer cable runs are possible, but be aware of possible DiSEqC
switching problems which may vary between satellite receivers.
Mount suitable F-connectors on the coax cable coming from the LNB units (or another cascaded
Multiswitch unit). Connect them to the correct inputs of the multi switch. Observe correct colour coding.
Double-check that correct SAT polarities are connected to correct multiswitch inputs.
Preferably use a suitable outlet socket in the apartment at the satellite receiver to separate the terrestrial
RF and satellite SAT-IF signals (e.g.: TOU 01S, EDA 302 F). NOTE: The SAT outlet must have DC pass.
Outputs on the multi switch not in use should be terminated with DC-blocked 75 ohm terminators.
DC supply for LNBs and/or Line Amplifier(s) can be done via the built-in PSU (P-EU and A-EU versions)
and can be done by attaching an external power supply to any of the TMS 9XX CE cascade units.
Cascade switches can also take DC Supply from the trunk lines if a PSU is connected elsewhere in the
trunk. Please consider total system power consumption requirements and add PSUs as needed. DC-
blockers may need to be inserted to avoid power supply conflicts.
The switch itself only needs a receiver to work on SAT-IF (Active A-versions needs a PSU for RF to work).
Apply mains power to the installation power supply(es) only when all connections are done and you are
sure there are no short circuits present on the coax cables (use a multi-meter to check and verify).
Satellite receivers can now be connected, turned on and set up. System is ready for use.
BEWARE: A high Signal Level does not guarantee the digital quality of your signal! Make sure to use a
suitable quality Field Strength Measurement Instrument that lets you keep track of, and ensure suitable
C/N, BER and MER Levels throughout the network.
Multiswitch colour coding layout for LNB inputs and outputs:
Type
BAND
Polarity
Switch voltage
Switch freq.
Colour coding
SAT
High Band
Horisontal
18 V DC
22 kHz
Yellow
Vertical
13 V DC
22 kHz
Red
Low Band
Horisontal
18 V DC
0 kHz
Green
Vertical
13 V DC
0 kHz
Black
TER
NA
White
Specyfikacje produktu
Marka: | Triax |
Kategoria: | przełącznik |
Model: | TMS 916 CE P |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Triax TMS 916 CE P, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje przełącznik Triax
4 Października 2024
4 Października 2024
Instrukcje przełącznik
- Nexa
- Flic
- Intelix
- Finder
- Leviton
- Wentronic
- Elektrobock
- Extron
- Extech
- Lindy
- Vacmaster
- Tripp Lite
- Steren
- DoorBird
- Kraus & Naimer
Najnowsze instrukcje dla przełącznik
9 Kwietnia 2025
9 Kwietnia 2025
7 Kwietnia 2025
5 Kwietnia 2025
4 Kwietnia 2025
4 Kwietnia 2025
4 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
2 Kwietnia 2025