Owner’s Manual
Cable Tester with
Wire Tracker
Model: T012-001-K
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2015 Tripp Lite. All rights reserved.
15-11-220-9334E1.indd 1 12/9/2015 3:45:00 PM

2
Package Includes
Product Features
Wire Tracking
• Main Tester
• Remote Probe Unit
• RJ45 Jumper Cable
• RJ11 Jumper Cable
• Alligator Clip Adapter
• Headphones
• 9V Battery (x2)
• Owner’s Manual
• Multi-Function Kit allows for both cable testing and wire tracking
• Find a single RJ11, RJ45, or BNC cable within a group of cables
• Determine the location of a short or breakage in non-powered wires
• Perform wire mapping on RJ45 cables, detecting shorts and open wires
• LED light on Remote Probe Unit for use in dark areas
Notes:
• The volume button is used to fine tune the tone generator. If you are having trouble with the
probe not honing in on a single cable, adjust the volume setting. When tracking a cable that has
power running through it, it is recommended to set the volume from 1-3. When tracking a non-
powered cable, set the volume from 6-8.
• The included headphones can be used when in a noisy environment to ensure you hear the
tone from the Remote Probe Unit.
• Flip the light switch on the side of the Remote Probe Unit to turn on the light for use in dark
areas.
1. If this is the first time you are using the product, insert a 9V battery into the battery
compartment of the Main Tester and the Remote Probe Unit. Flip the switch on the
Main Tester to the position. The LED will flash to indicate the Main Tester Scan Status
is ready for operation.
2. Connect the RJ11, RJ45, or BNC cable to be tracked to the corresponding port on
the Main Tester.
3. Flip the switch on the Remote Probe Unit to the position. The LED will Scan Power
illuminate to indicate the Remote Probe Unit is ready for operation.
4. Run the probe of the Remote Probe Unit along the group of cables until the tone
sounds, indicating you have found the desired cable.
15-11-220-9334E1.indd 2 12/9/2015 3:45:00 PM

3
Locating a Short or Breakage in a Non-Powered Cable
RJ45 Wire Mapping
Notes:
• Set the volume from 6-8 when locating a short or breakage.
• Locating a short or breakage can only be performed on a non-powered cable.
• The included headphones can be used when in a noisy environment to ensure you are hearing
the tone from the Remote Probe Unit.
• Flip the light switch on the side of the Remote Probe Unit to turn on the light for use in dark
areas.
1. Flip the switch on the Main Tester to the position. The LED will flash to Scan Status
indicate the Main Tester is ready for operation.
2. Connect the included alligator clip adapter to the corresponding port on the Main
Tester.
• When locating a , connect both alligator clips to the bare wires on the cable short
being tested.
• When locating a , connect the red alligator clip to one of the bare wires, breakage
leaving the black alligator clip free.
3. Flip the switch on the Remote Probe Unit to the position. The LED will Scan Power
illuminate to indicate the Remote Probe Unit is ready for operation.
4. Run the probe of the Remote Probe Unit along the cable. The tone will sound,
indicating that the area where the probe is currently located is undamaged. Continue
running the probe along the cable until the tone stops, which will be the location of
the short or breakage.
1. Flip the switch on the Main Tester to the Test Verify position. The LED will flash to
indicate the Main Tester is ready for operation.
2. Flip the switch on the Remote Probe Unit to the position. The LED will Scan Power
illuminate to indicate the Remote Probe Unit is ready for operation.
3. Connect RJ45 cable from the RJ45 port of the Main Tester to the RJ45 port of the
Remote Probe Unit.
4. The Pin LEDs on the Main Tester and Remote Probe Unit will illuminate per below.
When performing a Wire Mapping operation, pressing the button will change the Note: SET
speed at which the LEDs flash.
• – When a UTP cable is properly wired, the LEDs on both units will Good Cable
flash in sequence from 1 through 8. For a good STP cable, the LEDs will flash in
sequence from 1 through 8, including G.
• – In the case of a short, the LED(s) of the pin(s) in which a short is present Short
will not illuminate on the Remote Probe Unit. The LEDs on the Main Tester unit will
all continue to illuminate.
• – In the case of an open pin, the LED(s) of the open pin(s) will remain off on Open
both the Main Tester and Remote Probe Unit.
15-11-220-9334E1.indd 3 12/9/2015 3:45:00 PM
Specyfikacje produktu
Marka: | Tripp Lite |
Kategoria: | Niesklasyfikowane |
Model: | T012-001-K |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Tripp Lite T012-001-K, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Tripp Lite
15 Stycznia 2025
15 Stycznia 2025
15 Stycznia 2025
15 Stycznia 2025
15 Stycznia 2025
15 Stycznia 2025
9 Stycznia 2025
9 Stycznia 2025
9 Stycznia 2025
9 Stycznia 2025
Instrukcje Niesklasyfikowane
- Niesklasyfikowane Nabo
- Niesklasyfikowane Innoliving
- Niesklasyfikowane Siku
- Niesklasyfikowane Götze & Jensen
- Niesklasyfikowane Diana
- Niesklasyfikowane Bellari
- Niesklasyfikowane Interlogix
- Niesklasyfikowane Habitat
- Niesklasyfikowane Smartwares
- Niesklasyfikowane Dresden Elektronik
- Niesklasyfikowane TOGU
- Niesklasyfikowane 3M
- Niesklasyfikowane NUX
- Niesklasyfikowane Standard Horizon
- Niesklasyfikowane Heinner
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025