Instrukcja obsługi Uni-T UT161D
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Uni-T UT161D (6 stron) w kategorii multimetr. Ta instrukcja była pomocna dla 18 osób i została oceniona przez 9.5 użytkowników na średnio 4.5 gwiazdek
                        Strona 1/6
                    
                    
                    
United Kingdom • 
www.clasohlson.co.uk
English
Ver. 20210530
Digital Multimeter with USB Interface – Quick Start Guide  
Description
1.  NCV (Non-Contact Voltage) detector
2.  LCD display
3.  [ Hz% / USB ] buon
•  Short-press to select frequency measurement.
•  Short-press to select Duty Cyclemeasurement.
4.  [ Range ] buon
•  Short-press to change the measurement range. 
The buzzer will sound.
•  Long-press to return to Autorange (automac measuring 
range selecon mode).
5.  [ SELECT ] buon
6.  Funcon selector switch
7.  Test lead input terminals
8.  [ REL  / USB ] buon▲ 
•  Short-press to enter the relave value  
measurement mode.
•  Short-press to exit the relave value measurement mode.
•  Long-press to acvate or deacvate the RS232/USB funcon. 
The sleep funcon is deacvated when the RS232/USB 
funcon is acvated and   disappears from the display.
9.  [ PEAK/ MAX MIN ] buon
•  Short-press to toggle between max and min  
measured values.
•  Long-press to return to normal display mode.
10.  [ HOLD ] buon and backlight switch
•  Short-press to save a reading (data hold funcon),  
short-press once more to delete the reading.
•  Long-press to acvate the display backlight for 10 seconds.
Instructions for use
•  Warning: Consult a qualied electrician before using  
the instrument if you are at all unsure about its usage.
•  Always ensure that the correct funcon and range is selected. 
If in doubt about the correct range, start with the highest and 
work downwards.
•  When measuring voltage always ensure that the instrument is 
switched to the correct funcon range and not set to the  
current, resistance or diode test range.  
Always ensure that you use the correct test lead socket for the 
type of measurement to be made.
•  Make sure that the object to be measured is not “live”, i.e.  
conducng any current before connecng test leads in series 
with it (such as when measuring current).
•  Make sure that the test leads are in good condion with no 
damage to the insulaon.
Measuring voltage
Measuring DC voltage 
DC and AC current measurement
Art.no 36-8255  Model  UT161D
 Note: This is a quick start guide. A full instrucon manual in 
English can be downloaded from www.clasohlson.se
Please read the enre instrucon manual before using the  
product and then save it for future reference. We reserve the right 
for any errors in text or images and any necessary changes made 
to technical data. If you have any quesons concerning technical 
problems please contact our Customer Services.
Safety instructions
•  This measuring instrument is designed for indoor use.
•  Do not use this instrument if it or the test leads appear to be 
damaged, or if you suspect that the instrument might not work 
properly.
•  Make sure that your ngers are behind the nger guards when 
using the test leads.
•  Make sure that the power supply to the circuit being  
measured is turned o before taking any measurements.  
Even low currents can be dangerous!
•  To avoid shocks you need to be careful when you work with 
voltage higher then 60VDC or 30VAC RMS.  
Voltages higher than this pose a risk of severe electric shocks.
•  Set the rotary selector switch to the correct range and funcon 
before starng to take readings. The measurement range must 
not be changed during a measurement.
•  This instrument is protected by fuses, but they will not protect 
the instrument from all kinds of misuse. 
Display symbols
  The data hold funcon is acvated.
  The sleep mode is acvated.
  Indicates a negave reading
  Indicator for AC measurement.
  Indicator for DC measurement.
  The Autorange mode is acvated  
    (the meter automacally selects the range).
  The reading is too high for this measuring range.
  Indicator for the diode test.
  The connuity buzzer is acvated.
  Maximum and minimum reading.
   Data transmission in progress (USB).
  Low baery warning – replace the baery.
  REL is acvated, the stored value  
    minus the present value is displayed.
  Resistance: Ω ohms, kΩ (kiloohms),  
      MΩ (megaohms).
    Voltage: mV (millivolts), V (volts).
  Current: μA (microamperea),  
      mA (milliamperes), A (amperes).
  Capacitance: nF (nanofarads),  
      μF (microfarads), mF(millifarads).
  Frequency: Hz (hertz), kHz (kilohertz),  
      MHz(megahertz).
US B
A
U S B
RL
RL
2
4
5
6
3
7
8
9
10
1
1.  Connect the black test lead 
to   and the red test 
lead to  .
2.  Set the funcon selector 
to   for DC voltage 
measurement.
3.  If you wish to change 
the measurement range 
manually, short-press 
[ Range ] the required 
number of mes.
4.  Connect the test leads 
across the source or load to 
be measured.
1.  Connect the black test 
lead to   and the red 
test lead to   (for 
measuring 0–600 mA) or to 
 (for measuring 
between 600mA and 10A).
2.  Set the funcon selector to 
the desired measuring range 
,  . or
3.  The default measuring 
funcon of the mulmeter 
is DC, short-press 
[ SELECT ] to change to AC 
measurement.
4.  Connect the test leads in 
Hold (save the reading)
1.  Short-press [ Hold ] to save the present reading.
2.  The buzzer sounds once and   appears on the display when 
Hold is acvated.
3.  The reading is deleted if you press the buon once again.
Backlight 
Long-press [Hold/Light] to turn on the backlight. The light will turn 
o automacally aer 10 seconds.
Measuring AC voltage
1.  Connect the black test lead to   and the red test lead to 
.
2.  Set the funcon selector to   for AC voltage measurement.
3.  If you wish to change the measurement range manually,  
short-press [ Range ] the required number of mes.
4.  Connect the test leads across the source or load to be 
measured.
series with the load and source of the current to be measured.
5.  When measuring current between 600mA and 20A (without a 
fuse) follow the method above but connect the red test lead to 
20A max.
Measuring resistance
1.  Connect the black test lead 
to    and the red test 
lead to  .
2.  Set the funcon selector 
switch to resistance 
measurement  .
3.  Connect the test leads to 
the circuit to be tested.
Specyfikacje produktu
| Marka: | Uni-T | 
| Kategoria: | multimetr | 
| Model: | UT161D | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Uni-T UT161D, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje multimetr Uni-T
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         7 Października 2024
                        
                    
                                                            
                        
                         2 Października 2024
                        
                    
                                                            
                        
                         2 Października 2024
                        
                    
                                                            Instrukcje multimetr
- Mastech
- GW Instek
- Wago
- Joy-It
- Weltron
- Elro
- Etekcity
- Kewtech
- Rohde & Schwarz
- HT Instruments
- Silverline
- Projecta
- IWH
- Kurth Electronic
- Cosinus
Najnowsze instrukcje dla multimetr
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         26 Marca 2025
                        
                    
                                                            
                        
                         14 Marca 2025
                        
                    
                                                            
                        
                         14 Marca 2025
                        
                    
                                                            
                        
                         21 Lutego 2025
                        
                    
                                                            
                        
                         14 Stycznia 2025
                        
                    
                                                            
                        
                         12 Stycznia 2025
                        
                    
                                                            
                        
                         10 Stycznia 2025
                        
                    
                                                            
                        
                         10 Stycznia 2025
                        
                    
                                                            
                        
                         10 Stycznia 2025