Instrukcja obsługi Uni-T UT58E
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Uni-T UT58E (2 stron) w kategorii multimetr. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 3 użytkowników na średnio 4.8 gwiazdek
                        Strona 1/2
                    
                    
                    
Warning
To avoid electric shock or personal injury, read the
 "Safety Information carefully before using the
 Meter.
Overview
Unpacking Inspection
Open the package case and take out the Meter.  Check
the  following  items  carefully  for  any  missing  or
damaged part:
In the event you find any missing or damaged part, 
please contact your dealer immediately.
1     English Operating Manual                        1 pc
2     Test Lead                                                 1 pair
3     Multi-Purpose Socket                               1 pc
4     Test Clip
5     Point Contact Temperature Probe
6     Holster                                                          1 pc
7     
9V Battery (NEDA 1604, 6F22 or 009P)
1 pc
1 pair
1 pc
Item
Description
Qty
Safety Information
This Meter complies with the standard IEC61010: 
Pollution Degree 2; Overvoltage Category (CAT. II 1000V,
CAT. III 600V) and Double Insulation.
CAT. II: Local level, appliance, PORTABLE EQUIPMENT
etc., with smaller transient voltage overvoltages than
CAT. III
CAT. III: Distribution level, fixed installation, with smaller
transient overvoltages than CAT. IV
Use the Meter only as specified in this operating manual,
otherwise the protection provided by the Meter may be
impaired.
In this  manual, a 
actions that pose hazards to the user, or may damage
the Meter or the equipment under test.
A Note identifies the information that user should pay
attention to.
Warning identifies  conditions and
Warning
Description
To avoid possible electric shock or personal injury,
and to avoid possible damage to the Meter or to the
equipment under test, adhere to the following rules:
 Before using the Meter inspect the case.  Do not
      use the Meter if it is damaged or the case (or part
of the case) is removed.  Look for cracks or missing
      plastic.  Pay attention to the insulation around
      the connectors.
 Inspect the test leads for damaged insulation or
exposed metal.  Check the test leads for continuity.
      Replace damaged test leads with identical model
      number o
r electrical specifications before using
      the Meter.
 Do not apply more than the rated voltage, as
      marked on the Meter, between the terminals or
      between any terminal and grounding.
 The rotary switch should be placed in the right
      position and no any changeover of range shall
      be made during measurement  to prevent damage
      of the Meter.
 When the Meter works at an effective voltage
      over 60V in DC or 30V rms in AC, special care
      should be taken for there is danger of electric
      shock.
 Use the proper terminals, function, and range for
      your measurements.
 If the value to be measured is unknown, use the
      maximum measurement position and reduce the
      range stop by step until a satisfactory reading is
      obtained.
 Do not use or store the Meter in an environment
of high temperature, humidity, explosive, inflammable
and strong magnetic field.  The performance of
      the Meter may deteriorate after dampened.
 When using the test leads, keep your fingers
      behind the finger guards.
 Disconnect circuit power and discharge all high
      -voltage capacitors before testing resistance,
      continuity, diodes, capacitance or current.
 Before measuring current, check the Meter's
      fuses and turn off power to the circuit before
      connecting the Meter to the circuit.
 Replace the battery as soon as the battery indicator
          appears.  With a low battery, the Meter might
      produce false readings that can lead to electric
      shock and personal injury.
 Remove test l
eads and multi-purpose socket from
      the Meter and turn the Meter power off before
      opening the Meter case.
 When servicing the Meter, :use the replacement
 parts with the same model or identical electrical 
specifications.
 To avoid any damage to the meter or any accident,
do not alter the internal circuit of the Meter randomly.
 Soft cloth and mild detergent should be used to
      clean the surface of the Meter when servicing.
      No abrasive and solvent should be used to prevent
      the surface of the Meter from corrosion, damage
      and accident.
 The Meter is suitable for indoor use.
 Turn the Meter power off when it is not in use
      and take out the battery when not using for a long
      time.
 Constantly check the battery as it may leak when
      it has been using for some time, replace the battery
      as soon as leaking appears.  A leaking battery will
      damage the Meter.
International Electrical Symbols
AC (Alternating Current).
DC (Direct Current).
Grounding.
Double Insulated.
Low Battery Indication.
Warning.  Refer to the Operating Manual.
Conforms to Standards of European Union.
Diode.
Fuse.
Continuity Test.
( Figure 1)
The Meter Structure
(See Figure 1)
1  LCD Display
2  HOLD Button.
3  Rotary Switch
4  COM Input Terminal
5  POWER
6  Other Input Terminal.
7  mA Input Terminal
8  20A Input Terminal
Rotary Switch
Below table indicated for information about the rotary 
switch positions.
DC voltage measurement.
AC voltage measurement.
Transistor Test
AC Current Measurement
DC Current Measurement
Fcx Capacitance Test
o
C Temperature Measurement
Diode test
Continuity test
Resistance measurement.
Hz
Frequency Measurement
Display Symbols
(See Figure 2)
(See Figure 3)
( Figure 2)
4
Indicates negative reading.
5
Test of diode.
6
The continuity buzzer is on.
7
Date hold is active.
8
Connect
Terminal
Indicator of connecting test leads
into  different  input  terminals.
,mA, A
A:   Amperes (amps).  The unit of
      current.
mA: Milliamp. 1 x 10
-3
 or 0.001
         amperes.
V:     Volts. The unit of voltage.
mV:  Millivolt. 1 x 10
-3
 or 0.001 volts.
9
hFE        The Unit of Transistor Test
10
A
Hertz.  The unit of frequency in
cycles/second.
Kilohertz.  1 x 10
3
 or 1,000 hertz.
kHz
o
C: Centigrade temperature
o
F: Fahrenheit temperature
o
C,
o
F
F: Farad.  The unit of capacitance.
   F: Microfarad. 1 x 10
-6 
or 0.000001
       farads.
nF: Nanofarad. 1 x 10
-9
 or 0.000000001
      farads.
nF,    F
A
: 
Microamp. 1x 10
-6 
or 0.000001
       amperes.
Measurement Operation
To avoid harms to you or damages to the Meter from
electric shock, never attempt to measure voltages
higher than 1000 or 1000V rms although readings
may be obtained.
( Figure 3)
Black     Red
B.  Measuring DC and AC Current  (See Figure 4)
( Figure 4)
Black     Red
"  " 
Warning
Never attempt an in-circuit current measurement
where the open circuit voltage between terminals
and ground is greater than 60V DC or 30V rms in AC.
If the fuse burns out during measurement, the Meter
may be damaged or the operator himself may be
hurt. Use proper terminals, function, and range for
the measurement. When the testing leads are
connected to the current terminals, do not parallel
them across any circuit.
The DC Current ranges
: 2mA, 200mA and 20A
The AC Current ranges
: 20mA, 200mA and 20A
1. Turn off power to the circuit.  Discharge all high-
     voltage capacitors.
2.
Insert the red test lead into the  20A or mA input
    terminal and the black test lead into the  COM terminal.
     When you measure current below 200mA, please
     insert the red test lead into the  mA input terminal.
     When you measure 200mA or above, insert the red
     test lead into the  20A input terminal.
3. Set the rotary switch to an appropriate measurement
    position in  A     or A    range.
4. Break the current path to be tested. Connect the red
    test lead in serial to the more positive side of the
    break and the black test lead to the more negative
    side of the break.
5. Turn on power to the circuit.
   The measured value shows on the display.
To measure current, do the following:
( Figure 5)
Warning
To avoid damages to the Meter or to the devices under
test, disconnect circuit power and discharge all the
high-voltage capacitors before measuring resistance.
Note
 If the value of current to be measured is unknown,
      use the maximum measurement position, and reduce
      the range step by step until a satisfactory reading is
      obtained.
 For safety sake, the measuring time for high current
      should be less than 10 seconds and the interval time
      between 2 measurements should be greater than 15
      minutes
 When current measurement has been completed,
      disconnect the connection between the testing leads
      and the circuit under test, and remove the testing
      leads away from the input terminal of the Meter.
C. 
 (See Figure 5)
The resistance ranges are: 200
   ,2k   ,20k   ,2M   and
200M
Black     Red
D.  Testing Diodes and Continuity
(See Figure 6)
( Figure 6)
Black    Red
To measure resistance, connect the Meter as follows:
"1"
Warning
To avoid damage to the Meter or to the equipment
under test, disconnect circuit power and discharge
all high-voltage capacitors before measuring diodes.
To avoid harms to you, never attempt to input voltages
higher than 60V DC or 30V rms in AC
Measuring Diodes
Use the diode test to check diodes, transistors, and other
semiconductor devices.  The diode test sends a current
through the semiconductor junction, and then measures
the voltage drop across the junction.  A good silicon 
junction drops between 0.5V and 0.8V
Note
 In a circuit, a good diode should still produce a forward
,
,
s
No.     Symbol                      Description
1
The battery is low.
Warning: To avoid false
readings, replace the battery as soon 
as the battery indicator appears.
Indicator for AC voltage or current.
The displayed value is the mean
value.
3
AC
2
Warning Symbol.
Digital Multimeter Model UT58E is a 20000-count hand
-held instrument with remarkable features: ex-large 
LCD, steady operations, overload protection for all
 ranges and unique structure. It is designed with large
-scale integrated circuits and dual integral A/D converter
 as the core, which offers 28 measuring ranges and can
 measure AC/DC voltage, AC/DC current, resistance,
capacitance, transistor, diode and continuity. It is also 
equipped with data hold, full icon display and sleep mode 
functions, etc; 
DC&AC
 in parallel.
in parallel.
Measuring DC and AC Voltage
Measuring Resistance
Specyfikacje produktu
| Marka: | Uni-T | 
| Kategoria: | multimetr | 
| Model: | UT58E | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Uni-T UT58E, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje multimetr Uni-T
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         7 Października 2024
                        
                    
                                                            
                        
                         2 Października 2024
                        
                    
                                                            
                        
                         2 Października 2024
                        
                    
                                                            Instrukcje multimetr
- Biltema
- IWH
- Perel
- Megger
- Weltron
- Digi-tool
- Parkside
- Alecto
- Projecta
- Elma
- Greenlee
- Topcraft
- Bruder Mannesmann
- PeakTech
- Kurth Electronic
Najnowsze instrukcje dla multimetr
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         26 Marca 2025
                        
                    
                                                            
                        
                         14 Marca 2025
                        
                    
                                                            
                        
                         14 Marca 2025
                        
                    
                                                            
                        
                         21 Lutego 2025
                        
                    
                                                            
                        
                         14 Stycznia 2025
                        
                    
                                                            
                        
                         12 Stycznia 2025
                        
                    
                                                            
                        
                         10 Stycznia 2025
                        
                    
                                                            
                        
                         10 Stycznia 2025
                        
                    
                                                            
                        
                         10 Stycznia 2025