Instrukcja obsługi Uni-T UT801
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Uni-T UT801 (2 stron) w kategorii multimetr. Ta instrukcja była pomocna dla 15 osób i została oceniona przez 8 użytkowników na średnio 4.6 gwiazdek
                        Strona 1/2
                    
                    
                    
LCD Display
1.     Indicator of manual rangeManual Range
2.  Warning !       Indicator for Warning signal
3.              The battery is low
4.              Indicator for high voltage signal
5.              Indicator for Negative reading 
                              display
6.                        Indicator for AC voltage or currentAC
                               ( DC indicator do not display)
7.              Data hold is active
8.              Test of diode
9.              The continuity buzzer is on
10.   Number          Indicates testing reading
11. Units of measurement:
General Specications
1.  Maximum  Voltage  between  terminal  input  and 
COM: 1000V( except 200mV, 230V)
2. μA  mA terminal input protection: (CE)250mA 265V 
auto recovery fuse
3.  10A  terminal  input  protection:  (CE)F1  (10A  H 
250V) Fast type melted fuse Φ5x20mm
4.  Resistance input protection: PTC/250V
5.  Capacitance input protection:  (CE)F2, F3 (0.5A H 
250V) Fast type melted fuse Φ5x20mm
6.  Frequency input protection: PTC/250V
7.  Temperature  input  protection:  (CE)250mA 265V 
fuse
8.           terminal input protection: PTC/250V
9.    hFE  input  protection:    (CE)250mA  265V  auto 
recovery  fuse,  F3  (0.5A H  250V) Fast  type  melted 
fuse Φ5x20mm
10.  Dis pl ay:   L CD  full  fu nc tio n  signal  display, 
maximum reading is 1999(UT801) , 19999(UT802)
Updates 2-3 times / second
11.  Range: Manual
12.  Polarity Display:  Auto
13.  Overload indication: 1
14.  Battery Deciency:   
15.  Operating Temperature: 0
~40℃(32℉~104℉)
16.  Storing Temperature: -10
~50℃(14℉~122℉)
17.  Relative Humidity:  0℃~30 ℃
 below  ≤75%
                                      30
℃~40℃ ≤50%
18.  Electromagnetic Field: Under 1V/m the inuence 
of  radiated  radio-frequency  electromagnetic  field 
phenomenon,  Total  accuracy=  specific  accuracy+ 
measurement  5%,  Over  1V/m  radiated  radio-
frequency  electromagnetic  which  do  not  have  any 
reference data on this topic.
19.   Power: AC(external  power  adapter AC220V/
DC9V-200mA) or DC(internal battery type 2 R14/1.5V 
6 pieces)
20.  Product size: (300x245x105)mm
21.  Product  Net  Weight  :   About1500g(without the 
accessories)             
22.  Safety Compaliances : IEC 61010: CATⅡ
1000V
6.   Do  not  overload  voltage  or  current  on  EITHER 
between terminal and terminal OR  between terminal 
and grounding which indicate on meter limitation.
7.   The  rotary  switch  should  be placed  in  the  right 
position  and  no  any  changeover  of  range  shall  be 
made during  measurement  is conducted  to  prevent 
damage of the Meter.
8.  Do  not use or  store the meter  in an environment 
of  high  temperature,  humidity,  flammable  and 
electromagnetic  environment.   The  performance  of 
the meter may deteriorate after dampened.
9.    The  internal  circuit  of  the  meter  shall  not  be 
altered at will to avoid damage of the meter and any 
accident
10.    Replace  the  battery  as  soon  as  the  battery 
indicator “            ”Appears.    With  a  low  battery,  the 
meter might produce false  readings that can  lead to 
electric shock and personal injury.
11.  Turn the meter off when it is not is use and take 
out the battery when not using for a long time.
UT801/802 Operating Manual
Bench Type Digital Multimeters 
UT801/802 
Operating Manual
Overview
     Digital Bench-Type Multimeter Model UT801 is the 
maximum reading  1999  and 3 1/2 digits  and UT802 
is  the  maximum  reading  19999  and  4  1/2  digits, 
both  models  are  in  manual  range,  DC  / AC  current 
type  digital  multimeter, This  is  also  the  extra  large 
characters in LCD display backlight with full function, 
full measurement and full overload protection as well 
as  a  good product  design outlook, In  addition  to  all 
the  conventional  features  include  DC/AC  voltage, 
DC/AC current,  resistance,  frequency, capacitance, 
tem p e ratur e  ℃ ,   Tra n sistor  hF E、di ode   an d 
continuity buzzer.
         This  operating  manual  covers  information  on 
safety  and  cautions.    Please  read  the  relevant 
information  carefully  and  observe  all  the  Warnings 
and Notes strictly.
Unpacking Inspection
      Open the package case and take out the Meter. 
Check the following items carefully to see any missing 
or damaged part.  If you nd any missing or damage, 
please contact your dealer in your country.
 ●  Operating Manual                             1 piece
 ●  Test Lead                                          1 pair
 ●  Alligator Clip                                      1 pair
 ●  K Type Temperature Probe               1 piece
     ( For the temperature under 230
℃testing)      
 ●  Multi-Purpose Socket          1 piece
 ●  Power Cord                                       1 piece  
     (AC220V 50Hz DC9V/200mA)                         
Safety Information
          Th is  Me te r  c omp li es  wi th  th e  st and ard s 
IEC61010-1  in  pollution  degree  2,  overvoltage 
category (CAT II 1000V) and double insulation. If you 
can not follow up this operating instruction to use the 
meter  and  it  reduces  the  chance  to have  an  using 
protection.
1.   Before  using  the  Meter  and Test  Leads  inspect 
both  items.   Do  not  use  the Meter  and  Test  Leads 
if  it  is  damaged  or  the case (or  part  of  the  case) is 
removed or  no  reaction  on  LCD  display.  Prohibited 
to use the  meter without housing or housing without 
screw x up in order  to avoid  possible electric  shock 
or  to avoid  possible  damage  to  the meter  or to  the 
equipment under test.
2.   If  the damage  of test  leads, use only  the  same 
model  number  or  identical  electrical  specifications 
replacement parts.
3.   Do not  use  your  finger  to  touch on  any  testing 
cable,  connector,  unused  terminal  input  or  circuit 
during the testing stage
4.   When  the  meter working  at  an  effective  voltage 
over 60V in DC or 30V rms in AC, special care should 
be taken for there is danger of electric shock.
5.   Selecting  the  correct terminal  input  and  turn  the 
rotary  switch  to  select  the  measuring  function.   In 
case of no any idea on the value input of the current, 
just simply test from the high value to low one.
Unit of Voltage: The millivolt, volt
Unit of current: Microampere, milliampere, 
ampere
Unit of electrical resistance: Ohm, thousand 
ohms, trillion ohm
Unit of electrical capacity: Accepts the farad, 
the microfarad
Unit of Frequency: Kilohertz
Unit  of Temperature:  Degree Celsius Factor 
Unit of Triode enlargement: Times
mV, V  
μA, mA, A 
Ω, kΩ, MΩ
nF/μF 
kHz
℃
β
Operational Measurement Guide (see Diagram 1, 2, 
3)
Diagram 1
Diagram 2
Diagram 3
Functions
 Symbol   Terminal Input              Explanation
   V          V ←→ COM  DC Voltage Measurement
   V          V ←→ COM  AC Voltage Measurement
   Ω          V ←→ COM  Resistance Measurement
                V ←→ COM  Diode / Continuity Buzzer 
                                     Measurement
  kHz       V ←→ COM  Frequency Measurement
  A           mA μA ←→ COM mA/μA DC Current Measurement
             10A ←→ COM  ADCCurrent Measurement
   A        mA μA ←→ COM mA/μA AC Current Measurement
              10A ←→ COM  A AC Current Measurement
   F          V←→ mA μA   Capacitance Measurement
    (Use Multi-Purpose Socket)
             V ←→ mA μA  Temperature Measurement
      (Use Multi-Purpose Socket)
   hFE   V ←→mA μA  Triode Enlargement Factor
    (Use Multi-Purpose Socket)
  Measurement
℃
Functional Buttons
                Turn the power on and off Turn the display 
                backlight on and off(suitable for battery 
                supply, backlight turn on about 10 seconds 
                after auto  shut down.)
                Press Hold to enter and exit the hold  mode 
                in any mode, the meter beeps.
LIGHT 
HOLD
Specyfikacje produktu
| Marka: | Uni-T | 
| Kategoria: | multimetr | 
| Model: | UT801 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Uni-T UT801, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje multimetr Uni-T
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         7 Października 2024
                        
                    
                                                            
                        
                         2 Października 2024
                        
                    
                                                            
                        
                         2 Października 2024
                        
                    
                                                            Instrukcje multimetr
- Testo
- MGL Avionics
- HT Instruments
- Powerfix
- Biltema
- Mastech
- Kurth Electronic
- Gossen Metrawatt
- Ideal
- Laserliner
- Elro
- Micronta
- CEM
- Noyafa
- Workzone
Najnowsze instrukcje dla multimetr
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         26 Marca 2025
                        
                    
                                                            
                        
                         14 Marca 2025
                        
                    
                                                            
                        
                         14 Marca 2025
                        
                    
                                                            
                        
                         21 Lutego 2025
                        
                    
                                                            
                        
                         14 Stycznia 2025
                        
                    
                                                            
                        
                         12 Stycznia 2025
                        
                    
                                                            
                        
                         10 Stycznia 2025
                        
                    
                                                            
                        
                         10 Stycznia 2025
                        
                    
                                                            
                        
                         10 Stycznia 2025