User Manual
AMBIENT GAS MEMBRANE THERMOST
Read all the instruction carefully
   This thermostats is designed to regulate the temperature in domestic and 
  industrial environments.
 SAFETY WARNINGS
   During installation and operation of the device, it is necessary to comply 
with the following instructions:
1)  The device must be installed by a skilled person, in strict compliance with 
the connection diagrams
2)  Do not power on or connect the device if any part of it is damaged 
3)  After installation, inaccessibility to the connection terminals without 
appropriate tools must be granted
4)  The device must be installed and activated in compliance with current 
electric systems standards
5)  Before accessing the connection terminals, verify that the leads are not live
Code  Model  Contact  Functions
VE018800  KLIMA 2  NA  -
VE019600  KLIMA 3  NA + NC  -
VE020400  KLIMA 3L  NA + NC  Power on warning lamp
VE021200  KLIMA SI  NA + NC  ON/OFF + Power on warning lamp
VE022000  KLIMA IN  NA + NC  ON/OFF
VE023800  KLIMA SW  NA + NC  Summer/Winter
VE024600  KLIMA 2V  NA + NC  2 speed + Summer/Winter/OFF
VE268900  KLIMA 3V  NA + NC  3 speed + OFF
 TECHNICAL SPECIFICATIONS
•  Free mounted single-pole mechanical thermostat
•  Setting range: +5 / +30°C
•  Differential: Δ ≤t   1°C
•  Capacity of the contacts:  16(2,5)A 250V ~ for models KLIMA 2 e KLIMA 3 
    10(1,5)A 250V ~ for models  KLIMA 3L, KLIMA SI, KLIMA IN, 
KLIMA SW, KLIMA 2V, KLIMA 3V
•  Thermal gradient: 1°C / 15 min.
•  Sensitive element: vapour expansion lung
•  Class I equipment
•  Protection degree: IP20
•  Type of action: 1B
•  Silver contacts 1000/1000
•  Break or switching contacts
•  Pollution degree: 2 (normal)
•  Voltage pulse: 4kV 
•   Operating temperature: 0 ÷ 40°C
•   Operating humidity: 20 ÷ 90 %RH noncondensing
 INSTALLATION
  The thermostat should be tted at approximately 1.5 m from the ground avoid positioning 
it near doors, windows, sources of heat and in places where there is too much or too little 
ventilation.
1)  The thermostat can be tted  directly to the wall or to the ush-mounting box (centre 
distance 60 mm).
2)  Remove the knob, unscrew the screw of the cover and remove it
3)  a) x the base to the wall
  b) connect the thermostat earth by using the terminal marked with the earth symbol
  c)  follow the wiring diagram inside the cover; x the exible inseparable wires to the 
relative screw terminals
  d)  replace the cover, screws and knob.
 USER’S GUIDE
1)  Set the temperature required by turning the knob;
2)  To limit the setting eld:
  a) Isolate the power supply line
  b) Remove the knob
  c)  Insert the limit markers in the housing  
under the knob (17°C ÷ 23°C
  d) Return the knob to its housing.
 REFERENCE STANDARDS
Conformity with EU directives: 2014/35/EU (LVD), 2014/30/EU (EMCD)
is declared with reference to the following standard: EN 60730-2-9
DIMENSIONS
ISCOM004-2105 Mod. KLIMA
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
e-mail: info@vemer.it  -  web site: www.vemer.it 
83,7
76,5
82,9
60
60
31
39
CONNECTIONS
KLIMA 2
T
+°C
16(2,5)A 250V~
N
L
KLIMA 3
T
+°C
16(2,5)A 250V~
N
L
KLIMA 3L
T
+°C
10(1,5)A 250V~
N
L
KLIMA IN
ON OFF
T
+°C
N
L
10(1,5)A
  250V~
KLIMA SI
ON OFF
T
+°C
N
L
10(1,5)A
  250V~
KLIMA SW
T
+°C
N
L
10(1,5)A
  250V~
KLIMA 2V
OFF
I
II
T
+°C
N
L
10(1,5)A
  250V~
KLIMA 3V
T
+°C
III
OFF
I
II
N
L
10(1,5)A
  250V~
Note: 
for “heating” operation 
mode, remove the cable 
terminal which is inside 
the device from terminal 
3 to teminal 2.
information to users pursuant to art. 14 of the directive 
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment  or packaging, 
this means the product must not be included with other general 
waste at the end of its working life.
The user must take the worn product to a sorted waste center,  
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
 to retailers with a sales area of at least 400 m
2, if they measure less than 25 cm.
An efficient sorted waste collection for the environmentally friendly disposal of the used device,
or its subsequent recycling, helps avoid the potential negative effects on the environment
and people’s health, and encourages the re-use and/or
recycling of the construction materials.
Specyfikacje produktu
| Marka: | Vemer | 
| Kategoria: | Termostaty | 
| Model: | Klima SW | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Vemer Klima SW, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Termostaty Vemer
                        
                         7 Sierpnia 2024
                        
                    
                                                            
                        
                         6 Lipca 2024
                        
                    
                                                            Instrukcje Termostaty
- SilverCrest
- Buderus
- Plieger
- Danfoss
- Delta Dore
- Remeha
- Drayton
- Fantini Cosmi
- Heimeier
- Salus
- Theben
- Xavax
- BTicino
- Junkers
- White Rodgers
Najnowsze instrukcje dla Termostaty
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         25 Stycznia 2025
                        
                    
                                                            
                        
                         15 Stycznia 2025
                        
                    
                                                            
                        
                         15 Stycznia 2025
                        
                    
                                                            
                        
                         14 Stycznia 2025
                        
                    
                                                            
                        
                         13 Stycznia 2025
                        
                    
                                                            
                        
                         13 Stycznia 2025
                        
                    
                                                            
                        
                         13 Stycznia 2025
                        
                    
                                                            
                        
                         15 Października 2024
                        
                    
                                                            
                        
                         15 Października 2024