Instrukcja obsługi Vimar 00296


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Vimar 00296 (2 stron) w kategorii gniazdo ścienne. Ta instrukcja była pomocna dla 16 osób i została oceniona przez 8.5 użytkowników na średnio 4.6 gwiazdek

Strona 1/2
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com
49401632A0 01 2104
00296
T EST
T EST
LINE
GRN
HOT
WHITE
Receptacle
Outlet
Mounting
bracket
Grounding terminal (Green):
Connection for bare copper
or green wire
LINE
White terminal
(Silver):
Connection for
LINE cable’s
white wires
LOAD
White terminal
(Silver):
Connection for
LOAD cable’s
white wires
Screw (terminal) colors:
Green = Grounding terminal
Silver = White terminals
Brass = Hot terminals
LINE
Hot terminal (Brass):
Connection for the LINE
cable’s black wire
LOAD
Hot terminal (Brass):
Connection for the LINE
cable’s black wire
A yellow sticker covers
the LOAD terminals.
Do not remove the
sticker at this time
TEST button:
See “Procedure”
Trip
indicator light
RESET
RESET
RESET button:
See “Procedure”
DESCRIPTION.
A GFCI receptacle is different from conventional receptacles. In the event of a ground
fault, a GFCI will trip and quickly stop the flow of electricity to prevent serious injury.
CHARACTERISTICS.
Rated voltage 125 V 60 Hz.~
• Rated current corresponding to the socket outlet standard 15 A.
GFCI Class A (trip 6 mA or more).
Definition of a ground fault:
Instead of following its normal safe path, electricity passes through a person’s body
to reach the ground. For example, a defective appliance can cause a ground fault. A
GFCI receptacle does not protect against circuit overloads, short circuits, or shocks.
For example, you can still be shocked if you touch bare wires while standing on a
non-conducting surface, such as a wood floor.
TEST YOUR WORK.
Why perform this test?
If you miswired the GFCI, it may not prevent personal injury or death due to a
ground fault. (electrical shock).
If you mistakenly connect the LINE wires to the LOAD terminals, the GFCI will still
operate like an ordinary receptacle, but it will not interrupt a ground fault.
T EST
T EST
SET
RES
EST
TES
RESET
RESET
T EST
T EST
SET
RESE
Procedure:
(a) This GFCI is shipped from the factory in the
tripped condition and can not be reset until it
is wired correctly and power is supplied to the
device. Plug a lamp or radio into the GFCI (and
leave it plugged in). Turn the power ON at the
service panel. Press the RESET button fully,
make sure the lamp or radio is ON. If the lamp
or radio is still OFF or the RESET button can
not be engaged, go to the Troubleshooting
section because LINE and LOAD wiring con-
nection have been reversed.
(b) Press the TEST button fully, the GFCI will trip
and the lamp or radio will be OFF. To restore
power, press the RESET button.
(c) If you installed your GFCI using CONNECTION
B, plug a lamp or radio into surrounding
receptacles to see which one(s), in addition to
the GFCI, lost power when you pressed the
TEST button. Do Not plug life saving devices
into any of the receptacles that lost power.
Place a “GFCI Protected” sticker on every
receptacle that lost power. Then press the
RESET button to reset the GFCI.
(d) Press the TEST button (then RESET button)
every month to assure proper operation. If
the GFCI can not be reset, then it must be
replaced.
(e) If the GFCI consistently trips it indicates end of
life and GFCI must be replaced.
TROUBLESHOOTING.
Turn the power OFF and check the wire connections against the appropriate wiring
diagram in step CONNECTION A or CONNECTION B. Make sure that there are no
loose wires or loose connections. Also, it is possible that you reversed the LINE
and LOAD connections. LINE/LOAD reversal will be indicated by power remaining
ON at the GFCI after you press the GFCI’s TEST button. Reverse the LINE and
LOAD connections if necessary. Start the test from the beginning if you rewired any
connections to the GFCI.
CAUTION.
To prevent severe shock or electrocution always turn the power OFF at the service
panel before working with wiring.
PLACEMENT IN CIRCUIT:
The GFCI’s place in the circuit determines if it protects other receptacles in the circuit.
Placing the GFCI in position A will also provide protection to “load side” receptacles B and C. On the other
hand, placing the GFCI in position C will not provide protection to receptacles A or B. Remember that
receptacles A, B and C can be in different rooms.
FRONT VIEW BACK VIEW
LINE
GRN
LOAD
HOT
WHIT E
LINE cable brings
power to the GFCI
Mounting box
LOAD cable feeds power
to other receptacle(s)
Grounding
connection to box
(if box has a
grounding terminal)
Wire connector
Yellow sticker remain
in place to cover the
LOAD terminals
LINE
GRN
HOT
WHIT E
AT T E NTION
LINE cable brings
power to the GFCI
Wire connector
Mounting box
Grounding
connection to box
(if box has a
grounding terminal)
CONNECTION B.
CONNECTION A.
LINE
LOAD
LINE
LOAD
A
LINE
B C
Service
Panel
T EST
T EST
RESET
RESET
SAMPLE CIRCUIT:
Use this GFCI receptacle with copper or copper-clad wire. Do not use it with aluminum wire.
Do not install this GFCI receptacle on a circuit that powers life support equipment because if the GFCI
trips it will shut down the equipment.
Must be installed by a skilled person in accordance with national and local electrical codes
.
Two 2P+T 15 A 125 V~ 60 Hz American standard socket
outlets with Ground Fault Circuit Interrupter (GFCI), devi-
ce complete with mounting frame, to be completed with
3-module Plana or Neve Up cover plates.


Specyfikacje produktu

Marka: Vimar
Kategoria: gniazdo ścienne
Model: 00296

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Vimar 00296, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje gniazdo ścienne Vimar

Instrukcje gniazdo ścienne

Najnowsze instrukcje dla gniazdo ścienne

Adam Hall

Adam Hall 8747S3USB Instrukcja

13 Września 2024
Reer

Reer 32030 Instrukcja

10 Września 2024
Reer

Reer 32040 Instrukcja

10 Września 2024
Heitronic

Heitronic 35461 Instrukcja

24 Sierpnia 2024
Heitronic

Heitronic 40462 Instrukcja

24 Sierpnia 2024
Heitronic

Heitronic 36314 Instrukcja

24 Sierpnia 2024
Heitronic

Heitronic 36315 Instrukcja

24 Sierpnia 2024
Heitronic

Heitronic 21046 Instrukcja

24 Sierpnia 2024
Heitronic

Heitronic 35103 Instrukcja

24 Sierpnia 2024