Instrukcja obsługi Vimar 19196.M
                    Vimar
                    
                    przełącznik
                    
                    19196.M
                
                                
    Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Vimar 19196.M (6 stron) w kategorii przełącznik. Ta instrukcja była pomocna dla 9 osób i została oceniona przez 5 użytkowników na średnio 4.9 gwiazdek
                        Strona 1/6
                    
                    
                    
03996
03997
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com
EIKON
20196
ARKÉ
19196
PLANA
14196
20196-03996-03997EN  05  2204
20196, 19196, 14196 - Quid electronic switch for roller shutter with 
slat orientation with relay outputs for cos  0.6 motor 2 A 220-240 V~ φ
50/60 Hz, position saving.
03996 - Quid electronic relay module for roller shutter with slat orien-
tation with relay outputs for cosφ 0.6 motor 2 A 220-240 V~ 50/60 Hz, 
position saving, installation in junction boxes or connector block boxes.
The device is designed to control a load such as a roller shutter, shutter or curtain 
while  also  allowing the adjustment  of  the  position  of  the roller  shutter or  slats.  It 
is available in the version with 1-module double push button to match the Eikon, 
Arké and Plana wiring series or for retrofit controlled by double push button. The 
devices can be connected together and managed from a single centralised control. 
The  favourite  roller  shutter  position  can  be  saved  and  recalled  starting from  any 
initial position.
03997 - Quid roller shutter control unit module, 2 inputs for NO push 
button, 6 outputs for Quid roller shutter relay module 03996, 220-240 
V 50/60 Hz power supply, installation in junction boxes or connector 
block boxes.
The device, which can be installed inside connector block boxes, is  designed  to 
manage several groups of roller shutters and control them from a single point.
CHARACTERISTICS of art. 20196, 19196, 14196 and 03996.
• Rated supply voltage: 220 – 240 V~ 50/60 Hz.
• Absorption: 13 mA.
• Relay output
• Controllable loads at 220-240 V~:
-   resistive loads : 5 A (20,000 cycles); 
-   cos ø 0.6 motors: 2 A (20,000 cycles).
• Double push button for art. 20196-19196-14196
• LED for load status indication and programming.
• Terminals:
-   motor  (UP) and   (DOWN) relay contacts
-   line L 
-   neutral N 
-    C and C  group control input to connect to art. 20062-19062-14062. For 
art. 20196-19196-14196 additional local control input using art. 03997.
- in  art.  03996  dedicated  P and  P   input  for  local  control  (for  instance  art.  
20062-19062-14062, 20066-19066-14066).
• Number of roller shutters that can be connected: max. 20 
• Max. length of cables for each section: 50 m
• Possible functions:
-   roller shutter/curtain position adjustment.
-   slat position adjustment.
-  saving and calling  of  favourite  roller  shutter/curtain position  starting  from  any 
initial position.
-   control from interlocked or non-interlocked double push button.
• Dissipated power of art. 03996: max. 1 W.
• In  the event that  several roller  shutter relays  are connected in order to cen-
tralise the system, using control unit module 03997 or directly on the general 
control  without  additional  modules  in-between,  the  system  must  be  set  up 
with a single Hysteresis and/or RCBO circuit breaker.
• It should be used in dry, dust-free places at a temperature of between 0 °C and 
+45 °C.
Art. 03997 CHARACTERISTICS.
• Rated supply voltage: 220 – 240 V~ 50/60 Hz.
• Control via interlocked or non-interlocked double push button.
• In combination with art. 20196-19196-14196 is designed to insert an additional 
local control.
• Designed to control 3 groups of roller shutters.
• Number of roller shutters that can be connected: max. 20
• Number of group levels: max. 3
• Max. length of cables for each section: 50 m
• It should be used in dry, dust-free places at a temperature of between 0 °C and 
+45 °C.
CONFIGURATION of art. 20196,19196,14196 and 03996.
Configuration  is  done  using  the  device  dip  switch  and  the  control  push  buttons 
(see figures 20196-19196-14196 and 03996). N.B. For art. 03996 switch off the 
power supply before accessing the device and operating the dip switches.
TIMING
The relay  is set  by default  with  an operating time of  120  s;  to  modify this  value, 
proceed as follows:
• Lower the roller shutter/curtain until you reach the limit stop
• Position the dip switch on  ; the LED begins to flash (if you press   (SET DOWN) 
nothing happens)
• Press and hold down  ) to raise the roller shutter/curtain; the LED is perma (UP -
nently lit.
• Once the roller shutter/curtain reaches the limit stop, briefly press   ( ) or DOWN
 ( ). UP
• The LED starts to flash again and the roller shutter/curtain moves   for 1 s DOWN
and UP FOR 1 S.
• Replace the dip switch in the   position; the LED goes out.OFF
FAVOURITE POSITION
Important:  to  make this  setting  you first need to have completed  the TIMING 
procedure.
• Take the roller shutter/curtain to your favourite position.
• Press   ( )/UP  ( ) for 3 s or press briefly  ) or   ( ) 5 times; DOWN  (UP DOWN
the  roller  shutter/curtain  moves    for  1  s  and  for  1  s  to  confirm  the DOWN UP 
setting. 
RESET
Shift the dip switch from the   position to the   position to reset all the setOFF SET -
tings made. In the event of a power failure, all the settings remain saved.
LOCAL AND GROUP CONTROL BUTTON FUNCTIONS.
• Press and hold down (for more than 1 s) = roller shutter/curtain opening/closing.
• Press briefly (less than 1 s) = slat adjustment.
• Press  ( UP) or  (DOWN) briefly twice = recalls the favourite position.
INSTALLATION RULES.
• Installation must be carried out by qualified persons in compliance with the cur-
rent  regulations  regarding the  installation of  electrical  equipment  in the  country 
where the products are installed.
• The power supply circuit (L-N) must be protected against overloads by installing 
a C10 A automatic 1-way switch.
• Art. 03996 and 03997 can be installed inside junction boxes provided they have 
been declared suitable for electrical devices that dissipate energy.
REMOTE CONTROL RECEPTION.
Quid can be remote controlled using the following devices:
• DueFili+ video door entry system: Video Door App + art. 40507 + art. 69RH or 
69PH (programmed for 2 s timed actuation)
The DueFili+ system is designed to configure a timed actuation (relay art. 69RH 
or 69PH) and control it from video door entry indoor stations. If the indoor station 
is connected (art. 40507) actuation can be remote controlled via the Video Door 
App.
• IP video door entry system: Video Door App + art. 40607 + art. 40636 (pro-
grammed for 2 s timed actuation)
The IP video door entry system is designed to configure a timed actuation (relay 
art.40636) and control it from video door entry indoor stations. If the indoor sta-
tion is connected (art. 40507) actuation can be remote controlled via the Video 
Door App.
• GSM  thermostat  01913:  the  device  is  fitted  with  a  programmable  output  to 
which an auxiliary supporting relay needs to be connected (a common one-posi-
tion stable relay with a 230V coil is sufficient). Actuation is then controlled via the 
By-Phone App or the By-Clima App (or directly via SMS text message). 
REGULATORY COMPLIANCE.
LV Directive. EMC directive. EN 60669-2-1 standard.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces 
of lead.
Specyfikacje produktu
| Marka: | Vimar | 
| Kategoria: | przełącznik | 
| Model: | 19196.M | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Vimar 19196.M, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje przełącznik Vimar
                        
                         1 Kwietnia 2025
                        
                    
                                                            
                        
                         11 Marca 2025
                        
                    
                                                            
                        
                         11 Marca 2025
                        
                    
                                                            
                        
                         29 Grudnia 2024
                        
                    
                                                            
                        
                         29 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            Instrukcje przełącznik
- LogiLink
- SPC
- Vivotek
- EnGenius
- DataVideo
- Adder
- Aeon Labs
- Ebode
- Shelly
- SEADA
- SilverCrest
- Ernitec
- Nexa
- KlikaanKlikuit
- Pyle
Najnowsze instrukcje dla przełącznik
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         7 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025
                        
                    
                                                            
                        
                         4 Kwietnia 2025
                        
                    
                                                            
                        
                         4 Kwietnia 2025
                        
                    
                                                            
                        
                         4 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025