OPERATING MANUAL
Weller Tools GmbH
Carl-Benz-Str. 2
74354 Besigheim, Germany
Tel: +49 (0) 7143 580-0
Fax: +49 (0) 7143 580-108
www.wellerft.com
39077-1 / 0 .20149

72
9. Warranty
Warranty: (except for lters). The time is measured from date of invoice.
Always contact the supplier before returning a product.
The invoice has to be shown at the time of the complaint.
Content
1. Introduction 2
2. Content 2
3. Safety instructions 3
4. Put into operation 3
5. Troubleshooting 4
6. Maintenance and service 5
7. Technical data 6
8. Article numbers 6
9. Warranty 7
1. Introduction
Filter system designed to catch and eliminate hazardous gases and particles in different
applications like soldering, gluing, solvents etc. It is delivered as a complete kit containing
everything required for two work stations.
2. Content
1. Hose connection
2. Top
3. Locks
4. Power intake with fuse and
curcuit breaker
5. Control panel
6. Nozzle x 2
7. Extraction arm x 2
8. Pre lter
9. Main lter
8
9
6
7
1
2
3
4
5
1 year

36
7. Technical data
Width x height x depth 456 x 496 x 200 mm
Weight 12 kg
Sound level at 1 meter > 52 dB(A)
Voltage 100/240 V
Effect 100 watt
Glass tube fuse 2 x 6,3 AT, 250 V
Maximum suction capacity 100 m3/h
Blower capacity 140 m3/h
Micro lter HEPA class H13, Separation degree, MPPS >99,95 %
Gas lter - Separation degree >95 %
Pre lter F7
Filter minitoring system Yes
Warranty (excl. lter) 2 years
ESD approval, SP Dno 230-05-0189
CE-guidelines 73/23, 89/336, 89/392, 91/368,
92/31, 93/44, 93/68
RoHS Yes
8. Article numbers
MG130 Fume extraction 130-1000-ESD
MG130 (2x Arm 0F10 + 2x Nozzle FT-NL) 1 Filter system 30-1055-ESD
MG130 Filter system (2x Arm 0F10 + 2x ALFA-Nozzle) FT91000103
Main lter 30-2000-ESD 1
Pre lter (5 pc 30-2010 F7 s) 1
3. Safety instructions
The unit must not be exposed to temperatures exceeding 50° C, open ames or conden-
sated solvents.
Switch off the lter unit when changing lter.
4. Put into operation
The best possible gas ltration will be achieved if:
- Process air temperature in the gas lter < 38 °C
- Relative humidity < 60 %
- Gas molecules > 30 g / mol (ltration better with larger molecules)
- Boiling temperature of gas molecules > 0 °C
NOTE! The unit may dust some from the main lter after transportation.
Make sure the starting of the lter system is made in an appropriate room.
The suction capacity can be adjusted in three steps by pressing the reset button at the
control panel repeatedly.
Specyfikacje produktu
Marka: | Weller |
Kategoria: | maszyna do lutowania |
Model: | MG 130 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Weller MG 130, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje maszyna do lutowania Weller
3 Stycznia 2025
3 Stycznia 2025
31 Grudnia 2025
12 Października 2024
30 Września 2024
30 Września 2024
29 Września 2024
25 Września 2024
22 Września 2024
20 Września 2024
Instrukcje maszyna do lutowania
- maszyna do lutowania Epcom
- maszyna do lutowania PowerPlus
- maszyna do lutowania Awelco
- maszyna do lutowania RYOBI
- maszyna do lutowania Milwaukee
- maszyna do lutowania BaseTech
- maszyna do lutowania Sievert
- maszyna do lutowania Silverline
- maszyna do lutowania Einhell
- maszyna do lutowania CFH
- maszyna do lutowania Ersa
- maszyna do lutowania Monacor
- maszyna do lutowania Ferm
- maszyna do lutowania HQ
- maszyna do lutowania Trotec
Najnowsze instrukcje dla maszyna do lutowania
11 Stycznia 2025
5 Stycznia 2025
4 Stycznia 2025
4 Stycznia 2025
1 Stycznia 2025
1 Stycznia 2025
1 Stycznia 2025
1 Stycznia 2025
29 Grudnia 2024
26 Grudnia 2024