SYMBOLS
Refer to the manual Alternating Current
Double insulated  Dangerous Voltage
Complies with EU 
directives
Underwriters Labora-
tories.[Note: Canadian 
and US.]
Conforms to relevant 
Australian standards. 
Do not dispose of this 
product as unsorted 
municipal waste.
FOR USE BY COMPETENT PERSONS
Anyone using this instrument should be knowledgeable and trained about the 
risks involved with measuring voltage, especially in an industrial setting, and the 
importance of taking safety precautions and of testing the instrument before and 
after using it to ensure that it is in good working condition.
SAFETY INFORMATION
WARNING: Use extreme caution when testing live electrical circuits due to risk of 
injury from electrical shock.
Warnings and Precautions
The VP-440 conforms to IEC 61010-031:2002; CAT IV 1000 V, class II, pollution •
deg.2 and UL 61010-031.
This instrument is IEC 61010-031 certified for Installation Category IV (1000V). •
It is recommended for use in distribution level and fixed installations, as well 
as lesser installations, and not for primary supply lines, overhead lines and 
cable systems.
Warnings and Precautions
Do not exceed the maximum overload limits (see specifications) nor the limits •
marked on the instrument itself. Never apply more than 1000 V ac rms.
Observe the proper safety precautions when working with voltages above •
30 VAC rms to avoid electrical shock hazard.
Before and after hazardous voltage measurements, test the detector on a •
known source such as line voltage to determine proper operation.
Never ground yourself when taking measurements. Do not touch exposed •
circuit elements.
Do not operate the instrument in an explosive atmosphere.•
Do not expose this product to rain or moisture This increases the risk of fire or  •
electric shock.
Do not rely on this tester for detecting AC voltage on a shielded wire.•
Comply with local and national safety requirements.•
Use proper protective equipment as required by local or national authorities.•
INTRODUCTION
The VP-440 VoltProbe is an instrument for safely checking the presence of an AC 
voltage without making any disconnections in cables, wall sockets, fuses, circuit 
breakers, junction boxes, etc. No current flow is needed for correct operation.
OPERATION
Apply the plastic tip to any connection point or move it along an insulated cable. 1. 
When an AC voltage is detected, the red indicator in the plastic tip will 2. 
illuminate. 
A steady glow (not flash) indicates voltage presence. If there is no indication, 
voltage could still be present.  Operation may be affected by differences in socket 
design and insulation thickness and type.
  : If three phase equipment is being checked and one phase is open, the Caution
voltage is conducted back to the defective fuse through the other fuses and will give 
a faulty indication. 
MAINTENANCE AND REPAIR 
If there appears to be a malfunction during the operation of the meter, the 
following steps should be performed in order to isolate the cause of the problem: 
Check the battery. 1. 
Review the operating instructions for possible mistakes in operating procedure. 2. 
Except for the replacement of the batteres, repair of the voltage detector should 
be performed only by a Factory Authorized Service Center or by other qualified 
instrument service pe rsonnel. The front panel and case can be cleaned with a mild 
solution of detergent and water. Apply sparingly with a soft cloth and allow to dry 
completely before using. Do not use aromatic hydrocarbons or chlorinated solvents 
for cleaning. 
Battery Replacement
Rotate battery cap CCW to remove. Remove batteries and replace with (2) AAA 1.5 
volts alkaline batteries. Replace the cap. Note battery orientation on side of case.
SPECIFICATIONS:
Operating voltage: 50-1000 VAC (50 / 60 Hz)
Sensitivity: Tip illuminates red at 0.157 (4mm) distance from a wire carrying 220 VAC.
Operating Temperature: -20°C to +55°C (-4°F to 131°F) < 95% RH; (0 to 30 °C) < 75% 
RH; (30 to 40 °C); < 45% RH (40 to 55 °C)
Environment: < 2000m, indoor operation
Power: (2) AAA batteries 1.5 volts alkaline. NEDA 24A, IEC LR6
Dimensions: 147 x 20mm (5.8 x 0.8”)
Weight: 40 gr(1.5 oz)
LVD IEC 61010-031:2002  CAT III – 1000V  class II and pollution degree 2; cULus 
61010-031.
EMC: EN 61326-1:2006  This product complies with requirements of the following 
European Community Directives: 2004/108/EC (Electromagnetic Compatibility) and 
2006/95/EC (Low Voltage) as amended by 93/68/EEC (CE Marking). However, electrical 
noise or intense electromagnetic fields in the vicinity of the equipment may disturb 
the measurement circuit. Measuring instruments will also respond to unwanted 
signals that may be present within the measurement circuit. Users should exercise 
care and take appropriate precautions to avoid misleading results when making 
measurements in the presence of electronic interference.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Your Amprobe product will be free from defects in material and workmanship for 
1 year from the date of purchase. This warranty does not cover fuses, disposable 
batteries or damage from accident, neglect, misuse, alteration, contamination, or 
abnormal conditions of operation or handling. Amprobe’s warranty obligation is 
limited, at Amprobe’s option, to refund of the purchase price, free of charge repair, 
or replacement of a defective product .  Resellers are not authorized to extend 
any other warranty on Amprobe’s behalf. To obtain service during the warranty 
period, return the product with proof of purchase to an authorized Amprobe Test 
Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for 
details. This warranty is your only remedy . All other warranties - whether express, 
implied or statutory - including implied warranties of fitness for a particular purpose 
or merchantability, are hereby excluded. Neither Amprobe nor its parent company 
or affiliates shall be liable for any special, indirect, incidental or consequential 
damages or losses, arising from any cause or theory. Since some states or countries 
do not allow the exclusion or limitation of an implied warranty or of incidental or 
consequential damages, this limitation of liability may not apply to you.
Repair
All test tools returned for warranty or non-warranty repair or for calibration should 
be accompanied by the following: your name, company’s name, address, telephone 
number, and proof of purchase. Additionally, please include a brief description of 
the problem or the service requested and include the test leads with the meter. Non-
warranty repair or replacement charges should be remitted in the form of a check, a 
money order, credit card with expiration date, or a purchase order made payable to 
Amprobe® Test Tools.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting 
repair. During the warranty period any defective test tool can be returned to your 
Amprobe® Test Tools distributor for an exchange for the same or like product. 
Please check the “Where to Buy” section on www.amprobe.com for a list of 
distributors near you. Additionally, in the United States and Canada In-Warranty 
repair and replacement units can also be sent to a Amprobe® Test Tools Service 
Center (see below for address).
Non-Warranty Repairs and Replacement – US and Canada
Non-warranty repairs in the United States and Canada should be sent to a 
Amprobe® Test Tools Service Center. Call Amprobe® Test Tools or inquire at your 
point of purchase for current repair and replacement rates.
In USA   In Canada
Amprobe Test Tools   Amprobe Test Tools 
Everett, WA 98203   Mississauga, ON L4Z 1X9 
Tel: 888-993-5853   Tel: 905-890-7600 
Fax: 425-446-6390   Fax: 905-890-6866
Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe® Test Tools 
distributor for a nominal charge. Please check the “Where to Buy” section on www.
amprobe.com for a list of distributors near you.
European Correspondence Address* 
Amprobe® Test Tools Europe 
Beha-Amprobe GmbH 
In den Engematten 14 
79286 Glottertal, Germany 
Tel.: +49 (0) 7684 8009 – 0
*(Correspondence only – no repair or replacement available from this address. 
European customers please contact your distributor.)
VP-440
Non-Contact VoltProbe®
Battery cap
VoltProbe 
Voltage Sensor
CA III 1000v~ MAXT 
Rotate Cap CCW to remove
Vo ltProbe 
CA III 1000 V MAXT 
Specyfikacje produktu
| Marka: | Amprobe | 
| Kategoria: | Niesklasyfikowane | 
| Model: | VP-440 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Amprobe VP-440, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Amprobe
                        
                         3 Października 2024
                        
                    
                                                            
                        
                         30 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         27 Września 2024
                        
                    
                                                            
                        
                         23 Września 2024
                        
                    
                                                            
                        
                         16 Września 2024
                        
                    
                                                            
                        
                         15 Września 2024
                        
                    
                                                            
                        
                         15 Września 2024
                        
                    
                                                            
                        
                         13 Września 2024
                        
                    
                                                            
                        
                         13 Września 2024
                        
                    
                                                            Instrukcje Niesklasyfikowane
- Lumag
- Kubo
- Tiptop Audio
- Polyend
- Auralex
- Eonon
- Casablanca
- Snom
- ProFlo
- SEH
- Raymarine
- ZeeVee
- Ontech
- Empress Effects
- Lamar
Najnowsze instrukcje dla Niesklasyfikowane
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025