Fire Alarm Systems | D192G Notification appliance module
D192G Notification appliance module
www.boschsecurity.com
uSupervises 12 VDC or 24 VDC notification appliance
circuits (NACs)
uSupervised signal silencing switch
uNotification appliance circuit rated at 3.0 A
uMultiple module configurations
uMounts in panel enclosure
This module is used for wiring connections to remote
signaling devices. You can connect up to twelve
D192G modules to the same system on compatible
control panels. Wiring is supervised for open, short, or
grounded circuit faults.
The module powers notification appliances from the
control panel power supply or from an Underwriters
Laboratories, Inc. (UL 1481) Listed auxiliary 12 VDC or
24 VDC regulated/power鈥憀imited power supply for fire
protective signaling units and commercial/residential
burglar units. This feature allows the system to
support more signaling devices on longer wire runs. It
also allows the use of 12 V or 24 V notification
appliances requiring the appropriate power supply.
Functions
Supervises 12 VDC or 24 VDC NACs
The D192G powers the notification devices from either
the control panel's power supply or from a UL Listed
Auxiliary 12 VDC or 24 VDC regulated power-limited
power supply for use with Fire Protective Signaling
Units and Commercial and Residential Burglar Units.
The choice of power supply allows the use of 12 V or
24 V notification devices.
Supervised Signal Silencing Switch
The D192G module has a toggle switch for silencing
the notification devices while testing the alarm panel.
When this toggle switch is in the Silence (Off)
position, the module indicates a supervisory trouble
condition to the control panel.
Multiple Module Configurations
Several modules can be connected to the same zone
or point on the control panel. If individual
annunciation of a notification appliance circuit is
desired, D192G modules can be connected to
separate zones or points on鈥慴oard or through the
D8128D OctoPOPIT Eight鈥憄oint Expander.
Mounts in Panel Enclosure
The D192G mounts inside the control panel enclosure
using existing mounting holes or with a D137 or D138
Mounting Bracket. Refer to the control panel's
installation guide for more information on mounting.
Specyfikacje produktu
| Marka: | Bosch |
| Kategoria: | Niesklasyfikowane |
| Model: | D192G |
Potrzebujesz pomocy?
Je艣li potrzebujesz pomocy z Bosch D192G, zadaj pytanie poni偶ej, a inni u偶ytkownicy Ci odpowiedz膮
Instrukcje Niesklasyfikowane Bosch
5 Stycznia 2025
5 Stycznia 2025
22 Grudnia 2024
22 Grudnia 2024
22 Grudnia 2024
22 Grudnia 2024
22 Grudnia 2024
22 Grudnia 2024
22 Grudnia 2024
10 Grudnia 2024
Instrukcje Niesklasyfikowane
- Advance Acoustic
- Nxg
- Valueline
- Digitus
- Amplicom
- Petkit
- Eikon
- Medeli
- Hilti
- Manduca
- Holland Electronics
- Super Rod
- Brainstorm
- Vision
- MGL Avionics
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025