SMOKE DETEC
SMOKE DETEC
SMOKE DETEC
SMOKE DETECSMOKE DETECTOR CC-5/evo10
TOR CC-5/evo10
TOR CC-5/evo10
TOR CC-5/evo10TOR CC-5/evo10
INSTRUCTIONMANUAL
W
hat to do in case of fire
1
. Donotpanic;staycalm.
2
. Leavethebuildingasquicklyaspossible.Touchdoorstofeeliftheyarehot
beforeopeningthem.Useanalternateexitifnecessary.Crawlalongthefloor,
anddonotstoptocollectanything.
3
. Callthefiredepartmentfromoutsidethebuilding.
4
. Donotgobackinsideaburningbuilding.Waitforthefiredepartmenttoarrive.
N
ote: Theseguidelineswillassistyouintheeventofafire,
however,toreducethechanceofafirebreakingout,practisefiresafetyprocedures
andpreventhazardoussituations.
R
ecommended installation site
•
Ineverybedroomandchildren’srooms
•Inhallwaysandstairways(oneveryfloor)
•Basementandattic
•
Inroomswithelectricdevices
•
Family-andworkroom
What you should consider regarding the installation
•Smoke,heatandburningitemswillspreadhorizontallyafterrisingtotheceiling,
s
oinstallthealarminthemiddleoftheceilingofanordinarystructurehouse
•
Ifthealarmforsomereasoncannotbeinstalledinthemiddleoftheceiling,
thedistancebetweenthealarmandthewallcornershouldbeatleast50cm.
•Ifthelengthoftheroomorthehallismorethan30foot,youshouldinstall
severalalarmsinthatroomorhall.
•
Ifthewallorceilingisslanting,thealarmshouldbeinstalledatleast50cmaway
fromthehighestwallorceilingpointintheroom(Diagram4)
Declaration of Performance
ThissmokedetectorisinharmonisationwithallrequirementsoftheEUDirective
EN14604:2005/AC-2008.TheDeclarationofPerformancecanbefoundonour
websitewww.cordes-rauchmelder.de
Disposal
Wasteelectricalequipmentshouldnotbedisposedofinthehouseholdwaste!
ThedetectorshouldbedisposedofaccordingtoWEEEEUDirective2002/96/EC–
WEEE(WasteElectricalandElectronicEquipment).Ifyouhaveanyquestions,
pleasecontacttheresponsibleauthority.
Disclaimer
CORDESVertriebsgesellschaftmbHshallnotbeliablefordamageofanykind
(includingindividualorconsequentialdamage)resultingfromthefactthatthe
signalofthesmokealarmwasnotactivatedinthepresenceofsmoke.
Furthermore,CORDESVertriebsgesellschaftmbHshallalsonotbeheldliablefor
theconsequencesoffalseordeceptivealarmas: Costsresulting,forinstance,
fromoperationsofthefirebrigadesorkeyservicesarenotcovered.
CORDES VertriebsgesellschaftmbH,OpdeSolt42,22391Hamburg,Germany
T
hankyouforpurchasingoursmokealarmdevice.Pleasetakeafewminutesto
r
eadtheuser’smanualthoroughlyandfamiliariseyourselfandyourfamilywithits
operation.Keepthemanualforfuturereference.
P
roduct sPecifications:
Power supply DC3VLithiumBattery(built-in)
Electric consumption >8µA(Standby),>50mA(Alarm)
Sound pressure 85dB(A)/3m
Operating status redLEDflashesevery40s
O
perating temp. +0°Cto+40°C
Air humidity 10%to90%(non-condensing)
C
omplies with EN14604:2005/AC:2008
Description
T
heunitisaphotoelectricsmokealarmdevice.Withthephotoelectrictechnology,it
i
smoresensitivetodetectingslowsmolderfires.
Installation
Activation
P
ressthetestbuttonandholditformorethan3secondsuntiltheLEDison,and
r
eleaseitwithinthenext2seconds.Theunitwillgeneratea“beep”,indicatingthat
itisactivatedandgoesintoworkingmode.
Installation
•Removethefixingplugfromthebracket(useascrewdriverifnecessary)
(Diagram1).
•
Installthebracketontheceiling(Diagram2).
•Fitthealarmonthebracketandturnthealarmbodyclockwise,untilitmatches
withthebracket.
•Insertfixingpluginthegapbetweenthebracketandthebottom(Diagram3).
•Pressthetestbuttontotesttheunit
Do not install smoke alarm devices in the following locations
•Nearappliancesorareaswherenormalcombustionregularlyoccurs(kitchens,
nearfurnaces,hotwaterheaters).
•Inareaswithhighhumidity,suchasbathrooms.
•Nearairreturnsorheatingandcoolingsupplyvents.Installatleast3feetaway
fromtheseareas.Theaircouldblowsmokeawayfromthedetector,whichmay
causefailuretoalarm.
•Inroomswheretemperaturesmayfallbelow0˚Corriseabove40˚C,orwhereair
humidityishigherthan93˚C.
•Inextremelydusty,dirty,orinsect–infestedareas.
Operation
Testing
Youcantestthedetectorbypressingthetestbutton.Testthealarmweeklyto
ensureproperoperation.Thiswillsoundthealarmiftheelectroniccircuitry,horn,
andbatteryareworking.
DO NOT useanopenflametotestyouralarm,youcoulddamagethealarmor
ignitecombustiblematerialsandstartafire.
CAUTION: Duetotheloudness(85decibels)ofthealarm,alwaysstandan
arms-lengthawayfromtheunitwhentesting.
LED indicators
•Workingmode:theredLEDflashesonceevery40seconds.Thisindicatesthat
thesmokealarmdeviceisoperatingproperly.
•Alarmmode:theredLEDflasheseverysecond.Thisindicatesthatyouareeither
pressingthetestbuttonorthatthedetectorisgoingintoalarm.
•Silence(Hush)mode:theredLEDflashesonceevery8seconds,indicatingthe
smokealarmdeviceisinthealarmsilence(Hush)mode.
Alarm silence (silence mode)
•Whiletheunitisalarming,youcanpushthetestbuttonandpausethealarm
forapproximately10minutes.TheredLEDwillflashonceevery8seconds.
Thisindicatesthatthesmokealarmdeviceisrunninginthesilencemode.
•Thesilencefeatureistobeusedonlywhenaknownalarmcondition,suchas
smokefromcooking,activatesthealarm.
•Thesmokealarmdevicewillautomaticallyresetafterapproximately10minutes.
If,afterthisperiod,particlesofcombustionarestillpresent,thealarmwillsound
again.
•Thealarmsilencer(silencemode)canberepeateduntiltheairhasbeencleared
oftheconditioncausingthealarm.
CAUTION: Whileextremesmokedevelopmentthesilencemodewillbedeactivated
Maintenance, Cleaning and Battery charge level
•Inadditiontoweeklytesting,thealarmrequiresaperiodiccleaningtoremove
dust,dirt,anddebris.
•Useavacuumcleanerwiththesoftbrush.Vacuumallsidesandcoversofsmoke
alarmdevice.
•Undernormalconditionsthebatterywilllastupto10years
•Wheneverthebatteryfallsbelowacertainvoltagelevel,thealarmwillbleepand
theLEDlightwillflashevery40seconds.
•Whenthedetectorbleepsthefirsttime,thealarmwillstilloperateatfullcapabi-
lityforatleastanother30days.
WARNING: Thebatteryissealedincoverandnotreplaceable.
Diagram1
Diagram2
Diagram3
Diagram4
Insertfixingplug
housing
srews
plasticdowel
h
olesinthe
ceilingorwall
R
emovethefixingplug
GX XX XX
07 89 -C PR -X XX XX
XX
XX
C
C-5-CPR-001
E
N 14604:2005/AC:2008
09.05.2016
Specyfikacje produktu
Marka: | Cordes |
Kategoria: | Detektor dymu |
Model: | CC-5/evo10 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Cordes CC-5/evo10, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Detektor dymu Cordes
27 Grudnia 2024
27 Grudnia 2024
27 Grudnia 2024
3 Października 2024
23 Września 2024
23 Września 2024
23 Września 2024
Instrukcje Detektor dymu
- Swann
- TEF
- KlikaanKlikuit
- EVE
- Deltronic
- Calex
- Satel
- System Sensor
- Trust
- Vivanco
- DSC
- Alecto
- Ei Electronics
- Hager
- Jalo Helsinki
Najnowsze instrukcje dla Detektor dymu
29 Stycznia 2025
14 Stycznia 2025
13 Stycznia 2025
13 Stycznia 2025
30 Grudnia 2025
30 Grudnia 2025
30 Grudnia 2025
29 Grudnia 2024
29 Grudnia 2024
24 Grudnia 2024