UNPACKING 
Inspect the UPS upon receipt. 
The box should contain the following: 
(a) UPS unit 
(b) User’s manual 
(c) USB device cable 
DETERMINE THE POWER 
REQUIREMENTS OF YOUR EQUIPMENT 
1.  Ensure that the equipment plugged into 
the outlet does not exceed the UPS unit’s 
rated capacity (700VA/370W for SL700U, 
750VA/375W for SL750U, 900VA/450W 
for SL900UC and 950VA/510W for 
SL950U). If the rated capacities of the unit 
are exceeded, an overload condition may 
occur and cause the UPS unit to shut down 
or the circuit breaker to trip. 
2.  There are many factors that can aect 
the amount of power that your electronic 
equipment will require. For optimal system 
performance keep the load below 80% of 
the unit’s rated capacity. 
HARDWARE INSTALLATION GUIDE 
1.  Your new UPS may be used immediately 
upon receipt. However, after receiving a 
new UPS, to ensure the battery’s maximum 
charge capacity, it is recommended that 
you charge the battery for at least 8 hours. 
Your UPS is equipped with an auto-charge 
feature. When the UPS is plugged into an 
AC outlet, the battery will automatically 
charge whether the UPS is turned on or 
turned o. 
2.  With the UPS unit turned o and unplugged, 
connect your equipment requiring 
battery backup into the battery power 
supplied outlets. Plug the other peripheral 
equipment (printer, scanner, speakers) into 
the full-time surge protection outlets. 
DO NOT plug a laser printer, paper 
shredder, copier, space heater, vacuum, 
sump pump or other large electrical 
device into the “Battery and Surge 
Protected Outlets”. The power demands 
of these devices will overload and possibly 
damage the unit. 
3.  Plug the UPS into a 2-pole, 3-wire grounded 
receptacle (wall outlet). Make sure the 
wall branch outlet is protected by a fuse 
or circuit breaker and does not service 
equipment with large electrical demands 
(e.g. air conditioner, refrigerator, copier, 
etc.). The warranty prohibits the use of 
extension cords, outlet strips, and surge 
strips. 
4.  Press the power switch to turn the unit on. 
The Power On indicator light will illuminate 
green and the unit will “beep” twice. 
5.  If an overload is detected, an audible alarm 
will sound and the unit will emit one long 
beep. To correct this, turn the UPS o and 
unplug at least one piece of equipment 
from the battery power supplied outlets. 
Make sure the circuit breaker is depressed 
and then turn the UPS on. 
6.  To maintain optimal battery charge, 
leave the UPS plugged into an AC outlet 
at all times. 
7.  To store the UPS for an extended period 
of time, cover it and store with the battery 
fully charged. While in storage, recharge 
the battery every three months to ensure 
optimal battery life. 
8.  Ensure the wall outlet and UPS are located 
near the equipment being attached for 
proper accessibility. 
9.  Lay the UPS horizontally or use the key-
hole mounting slots to ax the UPS to the 
wall in the proper orientation. 
YOUR ULTIMATE ALLY IN POWER 
Cyber Power Systems (USA), Inc. 
4241 12th Avenue East, Suite 400  |  Shakopee, MN 55379  |  CyberPowerSystems.com 
SLIM BATTERY BACKUP UPS SERIES 
SL700U / SL750U / SL900UC / SL950U 
USER MANUAL 
FEATURES 
1.  Power On Switch 
2.  Power On Indicator (green) 
3.  Battery and Surge Protected Outlets 
4.  Full-Time Surge Protection Outlets 
5.  USB Charging Ports 
6.  Circuit Breaker 
7.  USB Port to PC 
8.  Wiring Fault Indicator (red) 
9.  Widely-Spaced Outlets 
Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed 
power protection, operation, and performance during the lifetime of the product. Please take a 
few minutes to register your product at: www.CyberPowerSystems.com/registration. 
Registration certifies your product’s warranty, confirms your ownership in the event of a product 
loss or theft, and entitles you to free technical support. Register your product now to receive the 
benefits of CyberPower ownership. 
CAUTION!  To prevent the risk of fire or 
electric shock, install in a temperature and 
humidity controlled indoor area free of 
conductive contaminants. (Please see 
specifications for acceptable temperature 
and humidity range). 
CAUTION! To reduce the risk of electric shock, 
do not remove the cover. There are no user- 
serviceable parts inside. 
CAUTION! Hazardous live parts inside can be 
energized by the battery even when the AC 
input power is disconnected. 
CAUTION! The UPS must be connected to an 
AC power outlet with fuse or circuit breaker 
protection. Do not plug into an outlet that is 
not grounded. If you need to de-energize this 
equipment, turn o and unplug the unit. 
CAUTION! To avoid electric shock, turn o the 
unit and unplug it from the AC power source 
before installing a computer component. 
CAUTION! To reduce the risk of fire, connect 
only to a circuit provided with 20 amperes 
maximum branch circuit over current 
protection in accordance with the National 
Electric Code, ANSI/NFPA 70. 
CAUTION! Not for use in a computer room as 
defined in the Standard for the Protection of 
Electronic Computer / Data Processing 
Equipment, ANSI/NFPA 75. 
CAUTION! Do not dispose of batteries in a fire. 
The batteries may explode. 
CAUTION! Do not open or mutilate batteries. 
Released electrolyte is harmful to the skin and 
eyes. It may be toxic. 
DO NOT USE FOR MEDICAL 
OR LIFE SUPPORT EQUIPMENT! 
CyberPower Systems does not sell products 
for life support or medical applications. 
DO NOT use in any circumstance that would 
aect operation and safety of life support 
equipment, any medical applications or 
patient care. 
DO NOT USE WITH OR NEAR AQUARIUMS! 
To reduce the risk of fire or electric shock, 
do not use with or near an aquarium. 
Condensation from the aquarium can cause 
the unit to short out. 
DO NOT USE THE UPS 
ON ANY TRANSPORTATION! 
To reduce the risk of fire or electric shock, do 
not use the unit on any transportation such 
as airplanes or ships. The eect of shock or 
vibration caused during transit and the damp 
environment can cause the unit to short out. 
PRODUCT REGISTRATION 
IMPORTANT SAFETY WARNINGS 
(SAVE THESE INSTRUCTIONS) 
This manual contains important safety instructions. Please read and follow all instructions carefully 
during installation and operation of the unit. Read this manual thoroughly before attempting to 
unpack, install, or operate your UPS. 
INSTALLING YOUR UPS SYSTEM  BASIC OPERATION 
1.  Power On Switch 
To turn the UPS on, press the power button 
for approximately 2 seconds - you will hear 
a constant tone (1 second) - and release 
after a short beep. 
To turn the UPS o, press the power button 
for approximately 2 seconds - you will hear 
a constant tone (1 second) - and release 
after two short beeps. 
Alarm setting: The audible alarm can be 
turned OFF or ON by quickly pressing the 
POWER button twice. The default setting 
is for the Alarm On. To turn the Alarm O, 
quickly press the power button twice. You 
will hear two short beeps when the Alarm 
is turned o. To turn the Alarm back ON, 
quickly press the power button twice. You 
will hear a single short beep when the 
Alarm is turned on. 
*When the Alarm is turned o, there will 
be no audible notification when the UPS 
reaches a low battery state. 
2.  Power On Indicator (green) 
This LED is illuminated when the utility 
power is normal and the UPS outlets are 
providing power, free of surges and spikes. 
3.  Battery and Surge Protected Outlets 
The unit has five battery powered 
and surge protected outlets to ensure 
temporary uninterrupted operation of your 
equipment during a power failure. 
(DO NOT plug a laser printer, paper 
shredder, copier, space heater, vacuum 
cleaner, sump pump, or other large 
electrical device into the “Battery and 
Surge Protected Outlets.” The power 
demands of these devices will overload 
and possibly damage the unit.) 
4.  Full-Time Surge Protection Outlets 
The unit has three surge suppression outlets. 
5.  USB Charging Ports 
SL750U/SL700U: 
Two USB-A ports, 5V 2.4A power output 
SL900UC/SL950U: 
One USB-A port (5V 2.4A), 
One USB-C port (5V 18W) 
6.  Circuit Breaker 
Located on the side of the UPS, the circuit 
breaker serves to provide overload and 
fault protection. 
7.  USB Port to PC 
The port allows connection and 
communication between the USB port on 
the computer and the UPS unit. The UPS 
communicates its status to the PowerPanel® 
Personal software. 
8.  Wiring Fault Indicator (red) 
This LED indicator will illuminate to 
warn the user that a wiring problem exists, 
such as bad ground, missing ground or 
reversed wiring. If this is illuminated, 
disconnect all electrical equipment from 
the outlet and have an electrician verify 
the outlet is properly wired. The UPS will 
not provide surge protection without being 
plugged into a grounded and properly 
wired wall outlet. 
9.  Widely-Spaced Outlets 
The UPS unit has two widely-spaced 
outlets, so AC power adapters can be 
plugged into the UPS without overlapping 
or blocking adjacent outlets. 
2 
3  4 
9 
3 
2 
4 
9 
1 
5 
7 
8 
6 
Specyfikacje produktu
| Marka: | CyberPower | 
| Kategoria: | nieskategoryzowany | 
| Model: | SL950U | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z CyberPower SL950U, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje nieskategoryzowany CyberPower
                        
                         28 Lipca 2024
                        
                    
                                                            
                        
                         28 Lipca 2024
                        
                    
                                                            
                        
                         28 Czerwca 2024
                        
                    
                                                            
                        
                         31 Maja 2024
                        
                    
                                                            
                        
                         29 Maja 2024
                        
                    
                                                            
                        
                         26 Maja 2024
                        
                    
                                                            
                        
                         25 Maja 2024
                        
                    
                                                            
                        
                         25 Maja 2024
                        
                    
                                                            
                        
                         24 Maja 2024
                        
                    
                                                            
                        
                         23 Maja 2024
                        
                    
                                                            Instrukcje nieskategoryzowany
- Rockford Fosgate
- Sonel
- Electrolux
- Anker
- Vertiv
- Plant Craft
- Martin Logan
- Enhance
- Bellari
- Makita
- Blaupunkt
- Azden
- Yellow Garden Line
- Maestro
- Altrad
Najnowsze instrukcje dla nieskategoryzowany
                        
                         28 Października 2024
                        
                    
                                                            
                        
                         28 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024