Strona 1/3

Contact Details
Pleasenotethat some contact ofthe details on
thisPDFdocumentmaynotbe current.
Pleaseuse the following detailsifyouneedto
contactus:
Telephone:0844 879 3588
Email:customer.services@gdcgroup.co.uk
The widecustomer alsosupportsection websiteofour features a
rangeof ofinformationwhichmaybe use availabletoyouandis
24 ahours day.Itincludes:
• Operating and installation instructions
• Easy ‘How to use’ guides for storage heaters
• Service and repairs
• Wheretobuyourproducts
• Literature downloads
• Heating requirement calculator
‐Visit www.dimplex.co.uk/support
A division of GDC Group Ltd
Millbrook House Grange Drive Hedge End Southampton SO30 2DF
www.dimplex.co.uk
Re
g
istered No: 1313016 En
g
land
VAT GB 287 1315 50004
EEE Producer Registration Number –
WEE/GE0057TS
Paper from sustainable sources

Installation and Operating Instructions
Dimplex Air Curtain - Single Phase Conversion Kit - CAB1PN
Suitable for use with the CAB10E, CAB15E & DAB10E (Surface & Recessed)
08/19538/0 Issue 4
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
IMPORTANT SAFETY ADVICE
ENSURE THE APPLIANCE IS EARTHED.
This work should only be carried out by a competent
electrician.
Always disconnect the supply before working on the
product.
Ensure the supply cables are of adequate current
carrying capacity and are protected by a suitable
fuse.
Ensure all wiring is fi xed clear of all moving parts and
heat sources.
This kit is designed for use with DAB15 models.not
This conversion kit consists of:
8 x 100mm x 2.5mm tie wraps
4 x Moss Plastic tie wrap clips
2 x Neutral link cable
1 x Live link cable
The instructions for the conversion kit should be
read in conjunction with the ‘Dimplex Air Curtain’
Instructions. All ‘Safety Advice’ to be heeded before
fi tting this kit.
General
The CAB10E, CAB15E and DAB10E are primarlity
designed for 400V~ 3P&N 50Hz operation, however in
the instance where it is not possible to utilise a 3-phase
supply, the units can be de-rated to a ½ heat stiing for
operation via a 230V~ 1P&N 50Hz supply.
Procedure
1. remove the outlet grille assemblies and, where
necessary, the bottom panel and inlet grille to gain
access to the element banks and terminal blocks as
shown in Fig. 1 below.
2. Remove the fi rst half heat (H1) star connection link
cable from both sides of each elmenet bank (Fig. 2 shows
the bottom red (H1)) star connection link cable replaced
with the supplied neutral star connection link cable.
3. Fix the push on clips (two on
either side) to the inside of the
pressure plate as shown in Fig.
1 (the supplied push on clips
are a press fi t into their fi xing
holes (ø3.5mm). Proceed
to attach the neutral star link
connection cable to the push
on clips using the tie wraps as
shown in Fig. 3 below.
Note: Due to extra cable length (for CAB15E) it is
necessary to loop the slack cable in the pressure plate and
secure it using a supplied tie wrap as shown in Fig. 1.
4. Connect the brass ferrule end of the neutral link cable
into the N of the terminal block (along with the Neutral of
the single phase supply) as shown in Fig. 4.
5. Also shown in Fig. 4 is the supplied (brown) Live link
cable, this should be linked from L1 (with connection of
Live from single phase supply) to L2 & L3.
The earth cable is connected as normal within the
terminal block (ensure the supply cable is fi xed
appropriately within the back panel using the correct
sized gland).
6. Check all switch settings operate, as stated within
the evaluation table (overleaf). Note: H2 should still be
connected (as per remote switch connection instruction
manual) even though it will not be utilised (this still allows
a ½ heat setting when switched to full heat rather than no
heat at all).
Figure 1.
Figure 3.
Figure 4.
BLUE
RED

Once the above loadings and switch settings have been
confi rmed as acceptable, proceed to replace the grille
assemblies, and where necessary, the bottom panel.
For reference purposes a full wiring schematic is detailed
above.
Please retain your receipt as proof of purchase.
Specyfikacje produktu
Marka: | Dimplex |
Kategoria: | Niesklasyfikowane |
Model: | DAB20E |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Dimplex DAB20E, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Dimplex
13 Stycznia 2025
30 Grudnia 2025
2 Października 2024
2 Października 2024
30 Września 2024
28 Września 2024
27 Września 2024
22 Września 2024
20 Września 2024
20 Września 2024
Instrukcje Niesklasyfikowane
- Niesklasyfikowane Kata
- Niesklasyfikowane Wagner SprayTech
- Niesklasyfikowane Pluto
- Niesklasyfikowane Yongnuo
- Niesklasyfikowane Dörr
- Niesklasyfikowane Tiger
- Niesklasyfikowane Ford
- Niesklasyfikowane T'nB
- Niesklasyfikowane Tripp Lite
- Niesklasyfikowane Socket Mobile
- Niesklasyfikowane Oster
- Niesklasyfikowane Eonon
- Niesklasyfikowane CaterCool
- Niesklasyfikowane Dirt Devil
- Niesklasyfikowane Viomi
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025