APPLICATION GUIDELINESONDITIONS OF USE / C
Water SupplyPotable Water
Water Temp.Max. 100°F (38°C), Min. 33°F (0.6°C)
Water Pressure30 - 100 psi (206.8 - 689.5 kPa)
Service Flow0.65 gpm maximum (2.46 lpm)
•It is essential that the manufacturer’s recommended installation, maintenance and filter replacement
requirements be carried out for the product to perform as advertised. See Use & Care Manual for
Warranty information.
•While testing was performed under standard laboratory conditions, actual performance may vary.
•The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standard 42,
Standard 53 and Standard 401.
•The compounds certified under NSF 401 have been deemed as “emerging compounds/incidental contami-
nants. Emerging compounds/incidental contaminants are those compounds that have been detected in drink-
ing water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public
acceptance/perception of drinking water quality.
PERFORMANCE DATA SHEET
Model: PureAdvantage™ PWF-1™-U Using Replacement Cartridge EPPWFU01™
WARNING
Read entire manual. Failure to follow all guides and rules could cause personal injury or property damage.
Check with your local public works department for plumbing codes. You must follow their guidelines as you install
the Water Filtration system.
Your Water Filtration system will withstand up to 100 lbs/in2 (psi) water pressure.
To reduce the risk associated with choking:
DO NOT allow children under 3 years of age to have access to small parts during the installation of this product.
To reduce the risk associated with the ingestion of contaminants:
DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after use of the system. Systems certified for cyst reduction may be used on disinfected water that may
contain filterable cysts.
10200 David Taylor Drive, Charlotte, NC 28262, 2008 ELECTROLUX HOME PRODUCTS, INC. 1-877-4ELECTROLUX (1-877-435-3287)
PN A20973401
NSF is a trademark of NSF International.
Substance
Reduction
Average
Influent
NSF/ANSI Specified
Challenge Concentration
Average %
Reduction/
Minimum
Reduction
Average Product
Water Concentration
Maximum
Permissible
Concentration
NSF Reduction
Requirements
NSF Test
Report
Chlorine2.0 mg/L2.0 mg/L ± 10%>97.4 / 97.4%0.05 mg/LJ-00297278N/A≥ 50%
Nominal Particulate
Class I
4,600,000
pts/mL
At least 10,000 particles/mL99.3 / 99.0%38,000 pts/ml≥85%J-00297279N/A
Asbestos290 MFL10 to 100 MFL; fibers greater than 10
µm in length
>99 / >99% < 1MLFN/A≥99%J-00297237
Atrazine8.8 ug/L9 ug/L ± 10%>94.3 / 94.3%0.0005 mg/L5 ug/LJ-00297270N/A
Benzene14 ug/L15 ug/L ± 10%0.0005 mg/L0.005 mg/LJ-00297271>96.5 / 96.5%N/A
Carbofuran80 ug/L80 ug/L ± 10%>98.8 / 98.8%0.001 mg/L40 ug/LJ-00297273N/A
Cysts*140,000
cycst/L
Minimum 50,000 cysts/L>99.99 / 99.99%<1 cyst/LN/A≥99.95%J-00297235
Endrin5.7 ug/L6 ug/L ± 10%0.2 ug/L2 ug/LJ-0029764696.4 / 94.8%N/A
Lead pH 6.5150 ug/L150 ug/L ± 10%99.6 / 99.3%0.0005 mg/L10 ug/LJ-00297265N/A
Lead pH 8.5150 ug/L150 ug/L ± 10%>99.7 / >99.7%0.0005 mg/L10 u/LJ-00297266N/A
Lindane2.0 ug/L2 ug/L ± 10%>99.0 / 98.9%0.02 ug/L0.2 ug/LJ-00297274N/A
Mercury @ pH 6.55.5 ug/L6 ug/L ± 10%0.2 ug/L2 ug/LJ-0029726896.3 / 96.3%N/A
Mercury @ pH 8.55.7 ug/L6 ug/L ± 10%94.5 / 89.5%0.3 ug/L2 ug/LJ-00297267N/A
O-Dichlorobenzene1800 ug/L1800 ug/L ±10%>99.9 / 99.9%0.0005 mg/L600 ug/LJ-00297647N/A
P-Dichlorobenzene200 ug/L225 ug/L ± 10%>99.7 / 99.8%0.5 ug/L75 ug/LJ-00297651N/A
Tetrachloroethylene14 ug/L15 ug/L ± 10%>96.4 / 95.8%0.0005 mg/L5 ug/LJ-00297648 N/A
Toxaphene (Pesticide)15 ug/L15 ug/L ± 10%0.001 mg/L3 ug/LJ-00297649>93.2 / 93.1%N/A
2,4-D (Herbicide)220 ug/L210 ug/L ± 10%1.6 ug/L70 ug/LJ-00297645 99.3 / 97.4%N/A
Atenolol220 ug/L200 ng/L ± 20%>95.5 / 95.5%10 ng/L30 ng/LJ-00297275N/A
Bisphenol A>99.1 / 99.1%2200 ng/L2000 ng/L ± 20%20 ng/L300 ng/LJ-00297276N/A
Estrone140 ng/L140 ng/L ± 20%5 ng/L20 ng/LJ-00297276 >96.6 / 96.4%N/A
Ibuprofen (Pharma)440 ng/L400 ng/L ± 20%>95.5 / 95.3%20 ng/L60 ng/LJ-00297276 N/A
Naproxen160 ng/L140 ng/L ± 20%5 ng/L20 ng/LJ-00297276>96.8 / 96.7%N/A
Nonylphenol1500 ng/L1400 ng/L ± 20%50 ng/L200 ng/LJ-00297276>96.7 / 96.6%N/A
Phenytoin220 ng/L200 ng/L ± 20%>95.5 / 95.5%10 ng/L30 ng/LJ-00297276N/A
Trimethoprim140 ng/L140 ng/L ± 20%5 ng/L20 ng/LJ-00297275>96.6 / 96.5%N/A
* Based on the use of Cryptosporidium parvum oocystsContaminant reduction determined by NSF testing.
CAUTION
To reduce the risk associated with property damage due to water leakage
or flooding:
•Read and follow Use & Care Manual instructions before installation and
use of this system.
•Change the disposable filter cartridge at the recommended interval; the
disposable filter cartridge MUST be replaced every 6 months or sooner.
•Failure to replace the disposable filter cartridge at recommended
intervals may lead to reduced filter performance and failure of the filter,
causing property damage from water leakage or flooding.
• Installation and use MUST comply with all state and local plumbing codes.
•Protect from freezing, remove filter cartridge when temperatures are
expected to drop below 33° F (4.4°C).
• DO NOT install systems in areas where ambient temperatures may go
above 110° F (43.3°C).
•DO NOT install on hot water supply lines. The maximum operating water
temperature of this filter system is 100°F (37.8°C).
REPLACEMENT CARTRIDGE INFORMATION
Replacement Element: EPPWFU01™. For estimated cost of replacement
elements please call 1-877-4ELECTROLUX (1-877-435-3287) or visit us on the
web at ElectroluxAppliances.com
PERFORMANCE DATA
MODEL: PureAdvantage™PWF-1™-U. Use the replacement cartridge EPPWFU01™.
System tested and certified by NSF International against NSF/
ANSI Standard 42, Standard 53, and Standard 401 for the
reduction of substances listed below.
SYSTEM SPECIFICATIONS
Capacity200 gallons (757 liters)
Specyfikacje produktu
| Marka: | Electrolux |
| Kategoria: | Niesklasyfikowane |
| Model: | EPPWFU01 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Electrolux EPPWFU01, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Electrolux
3 Stycznia 2025
22 Grudnia 2024
22 Grudnia 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
5 Października 2024
5 Października 2024
Instrukcje Niesklasyfikowane
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025