Instrukcja obsługi Electrolux EWF2CBPA
Electrolux Niesklasyfikowane EWF2CBPA
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Electrolux EWF2CBPA (2 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 21 osób i została oceniona przez 3 użytkowników na średnio 4.9 gwiazdek
Strona 1/2

Electrolux Major Appliances, NA., 10200 David Taylor Drive, Charlotte, NC 28262P/N: 241546116
00005
00005
Substance ReductionNSF
Standard
NSF Reduction
Requirements
Average
Influent
Influent
Challenge
Concentration
Maximum
Permissible
Product Water
Concentration
Maximum
Effluent
Average
Effluent
Average
Percent
Reduction
Minimum
Percent
Reduction
Chlorine taste and odor42>/= 50%1.9 mg/L2.0 +/- 10%n/a0.05 mg/L0.05 mg/L97.40%97.40%
Cyst5399.95% 127500
cnt/mL Min. 50,000n/a1 cnt/L1 cnt/L99.99%99.99%
2,4-D53n/a0.222 mg/L0.210 +/- 10%0.07 mg/L0.043 mg/L0.012 mg/L94.50%80.60%
Alachlor53n/a0.385 mg/L0.04 +/- 10%0.002 mg/L0.002 mg/L0.0012
mg/L 97.00% 95.00%
Atrazine53n/a0.0083 mg/L0.009 +/- 10%0.003 mg/L0.0005
mg/L
0.0005
mg/L 94.00% 94.00%
Lead 8.5 pH53n/a0.147 mg/L0.15 +/- 10%0.01 mg/L0.002 mg/L0.0012
mg/L 99.10% 98.50%
Lead 6.5 pH53n/a0.142 mg/L0.15 +/- 10%0.01 mg/L0.001 mg/L0.001
mg/L 99.30% 99.30%
Mercury 8.5 pH53n/a0.006 mg/L0.006 +/- 10%0.002 mg/L0.0019 mg/L0.0015
mg/L 82.40% 68.20%
Mercury 6.5 pH53n/a0.006 mg/L0.006 +/- 10%0.002 mg/L0.0002
mg/L
0.0002
mg/L 96.50% 96.50%
Lindane53n/a0.0019 mg/L0.002 +/- 10%0.0002 mg/L0.00002
mg/L
0.00002
mg/L 98.90% 98.90%
Toxaphene53n/a0.0155 mg/L0.015 +/- 10%0.003 mg/L0.001 mg/L0.001
mg/L 93.50% 93.40%
Particulate class I42>/= 85%8,966,666
part./mL
Min. 10,000
part./mL >/= 85%14000
part./mL 10050 mL99.90%99.80%
Turbidity53n/a11 NTU11 +/- NTU0.5 NTU0.4 NTU0.1625
NTU 98.50% 96.40%
Endrin5366.60%0.006 mg/L0.006 +/- 10%0.002 mg/L0.0002
mg/L
0.0002
mg/L 96.80% 96.80%
Ethylbenzene5366.60%2.08 mg/L2.1 +/- 10%0.7 mg/L0.0005
mg/L
0.0005
mg/L 99.90% 99.90%
O-Dichloro benzene5366.60%1.8 mg/L1.8 +/- 10%0.6 mg/L
0 0005
.
mg/L
0 0005
.
mg/L 99.90% 99.90%
P-Dichloro benzene5366.60%0.22 mg/L0.225 +/- 10%0.075 mg/L0.0005
mg/L
0.0005
mg/L 99.80% 99.80%
Asbestos53> 99%72 MLF10-100 MLFNA 0.17 MLF0.17 MLF>99.00%>99%
Benzene5366.60%0.016 mg/L0.015 +/- 10%0.005 mg/L0.0005
mg/L
0.0005
mg/L 96.80% 96.80%
Carbofuran5350.00%0.079 mg/L0.08 +/- 10%0.04 mg/L0.0006
mg/L
0.0018
mg/L 97.80% 97.80%
MLF = Million fibers per liter
SYSTEM SPECIFICATION AND PERFORMANCE DATA SHEET
pure advantageTM NGFC-2000 Ice Maker Filter System
APPLICATION GUIDELINES / CONDITIONS OF USE
Water SupplyMunicipal or well applications
Water Temp.Max. 100°F (38°C), Min. 33°F (0.6°C) - For cold water use only
Water Pressure100 psi (690 kPa) Max. 30 psi (207 kPa) Min., as measured at the valve inlet
• Theltercartridgeshouldbereplacedatleasteverysixmonthsfortheproducttoperformasadvertised.PleaserefertotheUseandCareManualforgeneral
operationandmaintenancerequirements.Yourrefrigeratorwillhaveanelectroniclightonthefreezerdoordispenserthatlightsupyellowwhenthelterisalmost
readyforreplacementandlightsupredwhentheltermustbereplaced.Theindicatorispressedforapproximately3-10secondstoresetafterreplacingthe
ltercartridge.PleaserefertotheUse&CareManualforcompleteinstructions.ThewaterlterstatuslightonthismodelisnottestedorcertiedbyNSF.
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfectionbeforeorafterthesystem.Systemscertiedforcyst
reductionmaybeusedondisinfectedwatersthatmaycontainlterablecysts.
• Whiletestingwasperformedunderstandardlaboratoryconditions,actualperformancemayvary.Highsedimentareasmayrequiremorefrequentltercartridgereplacement.
• pure advantageTMNGFC-2000WaterFilterSystemwillabsorbbadtastesandodorsinbothicecubesanddrinkingwater.
SYSTEM SPECIFICATIONS
Flow RateIceMaker-3.4to4.3oz(99-125cc)per6.3secondsat60psi(asmeasuredatvalveinlet)
Dispenser-60ozperminute(0.5gpmor1.9litersperminute)at60psi(asmeasuredatvalveinlet)
Capacity240 gallons (908.5 liters)
SystemConstruction FilterHousingAssembly-Polypropylene Plastic
WaterStorageTank-PolyethylenePlastic
Tubing-PolyethylenePlastic
FilterMedia-ExtrudedCarbonBlock
REPLACEMENT CARTRIDGE INFORMATION
Replacement cartridges are available through your local Electrolux dealer by calling the Consumer Care Center at 1-877-435-3287.
PleasereferenceInstallationInstructionsintheUse&CareManualforreplacingthecartridgeandwarrantyinformation.Estimatedcostforthereplacementltercartridgekit:
Less than $50.00
PERFORMANCE DATA
MODEL: advantagepure TM
NGFC-2000
Usethereplacementcartridgelistedbelow.
The advantagepure TMNGFC-2000systemwiththeFC-300cartridgehasbeentestedaccordingtoNSF/ANSI42/53forreductionof
thesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthesystemwasreducedtoaconcentration
lessthanorequaltothepermissiblelimitforwaterenteringthesystem,asspeciedinNSF/ANSI42/53.
Generaltestwaterparameters;pH=7.5+/-0.5Temp.20°C+/-3°C(68°F+/-5°F)Pressure=60psi(414kPa)@0.5gpm(1.9lpm)
Specyfikacje produktu
| Marka: | Electrolux |
| Kategoria: | Niesklasyfikowane |
| Model: | EWF2CBPA |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Electrolux EWF2CBPA, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Electrolux
3 Stycznia 2025
22 Grudnia 2024
22 Grudnia 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
5 Października 2024
5 Października 2024
Instrukcje Niesklasyfikowane
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025