Instrukcja obsługi ESYLUX MD-FLAT 360i/8
ESYLUX
detektor ruchu
MD-FLAT 360i/8
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla ESYLUX MD-FLAT 360i/8 (18 stron) w kategorii detektor ruchu. Ta instrukcja była pomocna dla 13 osób i została oceniona przez 7 użytkowników na średnio 4.9 gwiazdek
Strona 1/18

1
MA00744003
ESYLUX GmbH | An der Strusbek 40
22926 Ahrensburg | Germany
info@esylux.com | www.esylux.com
Detailed operating instructions
MD-FLAT 360i/8 RW
EP10427886
MD-FLAT 360i/8 SW
EP10427893
MD-FLAT 360i/8 RB
EP10428074
MD-FLAT 360i/8 SB
EP10428081
MD-FLAT-E 360i/8 RW
EP10428548
MD-FLAT-E 360i/8 RW GST
EP10427862
MD-FLAT-L 360i/8 RW
EP10428609

OPERATING INSTRUCTIONS
2 / 18
GB
MD-FLAT 360i/8 RW MD-FLAT 360i/8 SB MD-FLAT-L 360i/8 RW
MD-FLAT 360i/8 SW MD-FLAT-E 360i/8 RW
MD-FLAT 360i/8 RB MD-FLAT-E 360i/8 RW GST
Table of contents
1 Description 3
2 Safety instructions 3
3 Operation / functionality 4
3.1 Conditions in which the lighting is switched on 4
3.2 Conditions in which the lighting is switched off 4
3.3 Switching delay – not in pulse mode 4
4 Installation / connection 5
4.1 Masking the field of detection 7
5 Activation 7
5.1 Overview of factory settings 7
6 Settings 8
6.1 Control via external “S” button 8
6.2 Configuring parameters via remote control 8
6.3 Mobil-PDi/MDi 8
6.4 Mobil-PDi/MDi temporary settings 9
6.5 Programming the Mobil-PDi/MDi 10
6.6 Mobil-PDi/MDi-universal 12
6.7 Mobil-PDi/MDi-universal temporary settings 12
6.8 Programming the Mobil-PDi/MDi-universal 13
7 Technical data 16
8 Troubleshooting 16
8.1 Maintenance 17
8.2 Cleaning 17
9 ESYLUX Manufacturer’s guarantee 18

OPERATING INSTRUCTIONS
3 / 18
GB
MD-FLAT 360i/8 RW MD-FLAT 360i/8 SB MD-FLAT-L 360i/8 RW
MD-FLAT 360i/8 SW MD-FLAT-E 360i/8 RW
MD-FLAT 360i/8 RB MD-FLAT-E 360i/8 RW GST
1 Description
The ESYLUX ceiling-mounted motion detector is a passive infrared presence detector
that responds to moving heat sources, such as people walking.
The motion detector is designed for areas with low levels of natural light, such as
hallways, cellars, staircases, changing rooms, toilets, garages etc.
Parameters can be configured using the ESYLUX Mobil-PDi/MDi and Mobil-PDi/MDi-
universal remote controls as well as via the manual setting elements.
Note: Use this product only as intended (as described in the user instructions).
The device must not be changed, modified or painted – doing so will void any warranty
claims. You must check the device for damage immediately after unpacking it.
If there is any damage, you should not install the device under any circumstances.
If you suspect that safe operation of the device cannot be guaranteed, you should turn
the device off immediately and make sure that it cannot be operated unintentionally.
2 Safety instructions
• Work on the 230-V power system must be carried out by authorised personnel only,
with due regard to the applicable installation regulations/standards
• Switch off the power supply before installing the system
• On the input side, the device is to be protected against short circuits with a 10-A circuit
breaker
• Protection type IP 20 for interior use
Specyfikacje produktu
Marka: | ESYLUX |
Kategoria: | detektor ruchu |
Model: | MD-FLAT 360i/8 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z ESYLUX MD-FLAT 360i/8, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje detektor ruchu ESYLUX
7 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024
12 Września 2024
10 Września 2024
6 Września 2024
1 Września 2024
30 Sierpnia 2024
26 Sierpnia 2024
Instrukcje detektor ruchu
- detektor ruchu Chuango
- detektor ruchu Megatron
- detektor ruchu Berker
- detektor ruchu BEA
- detektor ruchu Maxsa
- detektor ruchu KlikaanKlikuit
- detektor ruchu JUNG
- detektor ruchu EQ-3
- detektor ruchu Wentronic
- detektor ruchu XQ-lite
- detektor ruchu D-Link
- detektor ruchu Inovonics
- detektor ruchu Perel
- detektor ruchu Nexa
- detektor ruchu Elgato
Najnowsze instrukcje dla detektor ruchu
9 Stycznia 2025
29 Grudnia 2024
29 Grudnia 2024
26 Grudnia 2024
26 Grudnia 2024
25 Grudnia 2024
17 Grudnia 2024
17 Grudnia 2024
17 Grudnia 2024
17 Grudnia 2024