User's Guide
Pressure Meter
SD Card real-time datalogger
Model SDL700

2
SDL700-EU-EN V1.4 03/12
Introduction
Congratulations on your purchase of the Extech SDL700 Pressure Meter, an SD Logger Series
meter. This meter displays and stores pressure readings from optional pressure sensors in the
range of 30, 150, 300 psi. Supported measurement units are bar, psi, Kg/cm
2
, mm Hg, inch Hg,
meters of H
2
O, inches of H
2
O, atmosphere, hPA, and kPA. Logged data readings are stored on an
SD card for transfer to a PC. In addition, an RS232 port allows data streaming to a PC. This meter
is shipped fully tested and calibrated and, with proper use, will provide years of reliable service.
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer to the
manual for further information.
Meter Description
1. Pressure Sensor input jack
2. Measurement reading on LCD Display
3. HOLD and Backlight key
4. MAX-MIN key
5. SET and Clock key
6. PC interface jack
7. Reset button
8. Power Adaptor jack
9. SD card slot
10. ENTER and LOG key
11. Down arrow key ▼
12. Up arrow / UNIT key ▲
13. Power ON-OFF key
14. Unit of measure on the LCD Display
Notes: Items 6, 7, and 8 are located behind the snap-o compartment cover on meter’s right side.
Battery compartment, tilt stand, and tripod mount are located on the rear of the instrument

4
SDL700-EU-EN V1.4 03/12
Setup Mode
Basic settings at a glance
To view the current conguration of the meter with regard to time, date, and datalogging sampling
rate press the SET button momentarily. The meter will now display the conguration in quick
succession. If the information is missed on the rst try, simply press the SET button again until all of
the information is noted.
Accessing the Setup mode
1. Press and hold the SET button for at least 1.5 seconds to access the Setup menu.
2. Press the SET button momentarily to step through the available parameters. The parameter
type is shown on the bottom of the LCD and the current selection for that type is shown above
it.
3. When a parameter is displayed that is to be changed, use the arrow keys to change the
setting. Press the ENTER button to conrm a change.
4. Press and hold the SET button for at least 1.5 seconds to exit the Setup mode. Note that the
meter automatically switches out of the Setup mode if no key is pressed within 7 seconds.
5.
The available Setup parameters are listed below. Additional detailed information is provided
below this list:
dAtE
Set the clock (Year/Month/Date; Hours/Minutes/Seconds)
SP-t
Set the datalogger sampling rate (Hours/Minutes/Seconds)
PoFF
Automatic power-o management (Enable or disable the auto-power o function)
bEEP
Set the beeper sound ON/OFF
dEC
Set the numerical format; USA (decimal: 20.00) or European (comma: 20,00)
Sd F
Format the SD memory card
tYPE
Select the pressure range type (
2, 5, 10, 20, 50, 100, 200, and 400 Bar
)
Setting the Clock Time
1. Access the dAtE parameter.
2. Use the arrow keys to change a value
3. Use the ENTER button to step through the selections
4. Press and hold the SET button for at least 1.5 seconds to exit to the normal operation mode (or
simply wait 7 seconds for the meter to automatically switch to the normal operating mode).
5. The clock will keep accurate time even when the meter is switched o. However, if the battery
expires the clock will have to be reset after fresh batteries are installed.
Setting the Datalogger Sampling Time (Rate)
1. Access the SP-t parameter.
2. The sampling rate can be set from ‘0’ seconds (manual log mode) up to 8 hours, 59 minutes,
and 59 seconds.
3. Use the ENTER button to move through the Hours, Minutes, and Seconds digit groups and use
the arrow keys to change the digit values.
4.
Press the ENTER button to confirm the entry.
5. Press and hold the SET button for at least 1.5 seconds to exit to the normal operation mode (or
simply wait 7 seconds for the meter to automatically switch to the normal operating mode).
Specyfikacje produktu
Marka: | Extech |
Kategoria: | Niesklasyfikowane |
Model: | SDL700 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Extech SDL700, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Extech
8 Stycznia 2025
3 Października 2024
3 Października 2024
3 Października 2024
29 Września 2024
29 Września 2024
27 Września 2024
19 Września 2024
18 Września 2024
13 Września 2024
Instrukcje Niesklasyfikowane
- Niesklasyfikowane Parrot
- Niesklasyfikowane Tennsco
- Niesklasyfikowane Dobar
- Niesklasyfikowane Maclaren
- Niesklasyfikowane VCM
- Niesklasyfikowane TrueLife
- Niesklasyfikowane U-Line
- Niesklasyfikowane Thronmax
- Niesklasyfikowane Gallien-Krueger
- Niesklasyfikowane Fitbit
- Niesklasyfikowane LYYT
- Niesklasyfikowane WMD
- Niesklasyfikowane Gree
- Niesklasyfikowane Musical Fidelity
- Niesklasyfikowane Nemco
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025