Instrukcja obsługi Fluke 2AC


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Fluke 2AC (2 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 35 osób i została oceniona przez 18 użytkowników na średnio 4.8 gwiazdek

Strona 1/2
2AC
VoltAlert
Instruction Sheet
Read First: Safety Information
WX Warning
To avoid possible electric shock or personal injury:
If the Tester is used in a manner not specied by the manufacturer,
protection provided by the Tester may be affected.
Test on a known live source within the rated ac voltage range of the
product, both before and after use to ensure unit is in good working
condition.
When using the Tester, if tip does not glow, voltage could still be
present. The Tester indicates active voltage in the presence of
electrostatic elds of sufcient strength generated from the source
(MAINS) voltage. If the eld strength is low, the Tester may not provide
indication of live voltages. Lack of an indication occurs if the Tester is
unable to sense the presence of voltage which may be inuenced by
several factors including, but not limited to:
Shielded wire/cables
Thickness and type of insulation
Distance from the voltage source
Fully-isolated users that prevent an effective ground
Receptacles in recessed sockets/ differences in socket design
Condition of the Tester and Batteries
Do not use if the Tester appears damaged or if the Tester is not
operating properly. Specically examine the probe tip for cracks or
breakage before use. If in doubt, have the Tester serviced.
Do not apply more than the rated voltage as marked on the Tester.
Use caution with voltages above 30 V ac as a shock hazard may exist.
Comply with local and national safety requirements.
Use proper protective equipment as required by local or national
authorities.
Table 1. Symbols
TDouble Insulated.
XHazardous Voltage. Risk of electric shock.
WRisk of danger. Important information. See Instruction Sheet.
Conforms to relevant Canadian and US Standards.
Conforms to relevant European Union directives.
Conforms to relevant Australian standards.
Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website
for recycling information.
CAT IV Equipment is designed to protect against transients from the primary supply level.
(i.e. - electricity meter or overhead /underground utility service).
August 2010 Rev. 1, 7/11
© 2010-2011 Fluke Corporation. Specications are subject to change without notice. All rights
reserved. Printed in China.
FOR USE BY COMPETENT
PERSONS
Anyone using this instrument should be
knowledgeable and trained about the risks
involved with measuring voltage, especially
in an industrial setting, and the importance of
taking safety precautions and of testing the
instrument before and after using it to ensure
that it is in good working condition.


Specyfikacje produktu

Marka: Fluke
Kategoria: Niesklasyfikowane
Model: 2AC

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Fluke 2AC, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Fluke

Fluke

Fluke ii500 Instrukcja

9 Października 2024
Fluke

Fluke iSee TC01A Instrukcja

9 Października 2024
Fluke

Fluke 438-II Instrukcja

9 Października 2024
Fluke

Fluke T5-1000 Instrukcja

4 Października 2024
Fluke

Fluke TiX885 Instrukcja

29 Września 2024
Fluke

Fluke TiX875 Instrukcja

29 Września 2024
Fluke

Fluke TiX880 Instrukcja

29 Września 2024
Fluke

Fluke TiX870 Instrukcja

29 Września 2024
Fluke

Fluke 700HTH Instrukcja

29 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

SmallRig

SmallRig VB99 SE Instrukcja

29 Stycznia 2025
QSC

QSC TSC-8 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5130 Instrukcja

29 Stycznia 2025
Sunding

Sunding SD-581G Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5070 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS2010 Instrukcja

29 Stycznia 2025
OSEE

OSEE TX402 Instrukcja

29 Stycznia 2025