PRV240FS
Proving Unit
Instruction Sheet
Introduction
The PRV240FS Proving Unit (the Product) is an 
electronic voltage source. This Product provides 
a safe and easy method to verify proper operation 
of the T6-600/T6-1000 Electrical Tester with 
FieldSense technology or other test tools. Use 
it to verify either an energized source or a de-
energized source. Also use it in cases where no 
known voltage source is available to verify a test 
tool. 
The Product does not require personal protective 
equipment (PPE) unless your environment 
requires minimal PPE such as a hard hat, safety 
glasses, or ear plugs.
How to Contact Fluke
To contact Fluke, call one of the following 
telephone numbers:
 ●Technical Support USA: 1-800-44-FLUKE  
(1-800-443-5853)
 ●Calibration/Repair USA: 1-888-99-FLUKE  
(1-888-993-5853)
 ●Canada: 1-800-36-FLUKE (1-800-363-5853)
 ●Europe: +31 402-675-200
 ●Japan: +81-3-6714-3114
 ●China: +86-400-921-0835
 ●Singapore: +65-6799-5566
 ●Anywhere in the world: +1-425-446-5500
Or, visit Fluke's website at www.uke.com.
To register your product, visit  
http://register.uke.com.
To view, print, or download the latest manual 
supplement, visit  
http://us.uke.com/usen/support/manuals.
Safety
A Warning identies conditions and procedures 
that are dangerous to the user.
 Warning
To prevent possible electrical shock, re, 
or personal injury:
 ●Read all safety information before you 
use the Product.
 ●Carefully read all instructions.
 ●Do not alter the Product and use only as 
specied, or the protection supplied by 
the Product can be compromised.
 ●Do not touch voltages >30 V ac rms, 
42 V ac peak, or 60 V dc.
 ●Do not use the Product around 
explosive gas, vapor, or in damp or wet 
environments.
PN 4919689  September 2017
© 2017 Fluke Corporation. All rights reserved.  
Product specications are subject to change without notice.  
All product names are trademarks of their respective companies.  
 ●Do not use the Product if it operates 
incorrectly.
 ●Examine the case before you use the 
Product. Look for cracks or missing 
plastic. Carefully look at the insulation 
around the terminals.
 ●Do not use the Product if it is altered or 
damaged.
 ●Remove the batteries if the Product is 
not used for an extended period of time, 
or if stored in temperatures above 50 °C. 
If the batteries are not removed, battery 
leakage can damage the Product.
 ●You must close and lock the battery 
door before you operate the Product.
Symbols
Symbols used in the instructions or on the Product 
are shown in Table 1.
Table 1. Symbols
Symbol Denition
Consult user documentation.
WARNING. HAZARDOUS VOLTAGE. 
Risk of electric shock.
WARNING. RISK OF DANGER.
Battery
FieldSense Measurement: Fluke  
voltage/current sensing technique.
Certied by CSA Group to North 
American safety standards.
Conforms to relevant Australian EMC 
standards.
Conforms to European Union directives.
Conforms to relevant South Korean EMC 
Standards.
This product complies with the WEEE 
Directive marking requirements. The 
afxed label indicates that you must not 
discard this electrical/electronic product 
in domestic household waste. Product 
Category: With reference to the equipment 
types in the WEEE Directive Annex I, 
this product is classed as category 9 
"Monitoring and Control Instrumentation" 
product. Do not dispose of this product as 
unsorted municipal waste.
Operation
Table 2 is a list of the controls and interface of 
the Product. See Figure 1 for the location of each 
item.
Table 2. Product Overview
Item Description
AFunction selection
B+ Terminal 
CAC/DC LED
D  − Terminal
ETest Lead Ground Contact
FTest Lead Ground Contact LED
GFork saddle
HFinger Ground Contact LED
IFinger Ground Contact
FieldSense Measurement without Test Lead
Before verication, set up the T6 for a FieldSense 
measurement without the test leads. See the 
T6 Quick Reference Guide  .  
To verify measurement:
1.  Move the switch to the FieldSense position. 
See Figure 3.
2.  Insert the T6 fork into position on the Product.
3.  Push and hold the nger ground contact to 
activate the Product.
  The Product LED turns green and the T6 
display shows a 240 V measurement.
FieldSense Measurement with Ground Lead
Before verication, set up the T6 for a FieldSense 
measurement with the ground lead. See the 
T6 Quick Reference Guide  . 
To verify measurement:
1.  Move the switch to the FieldSense position. 
See Figure 4.
2.  Insert the T6 fork into position on the Product.
3.  Place the black test lead from the test tool 
into the test lead ground contact terminal and 
press down rmly. 
  The Product LED turns green and the T6 
display shows a 240 V measurement.
AC/DC Measurement
Before verication, set up the T6 or other test tool 
for ac/dc measurement with the test leads. 
To verify measurement:
1.  Move the switch to the AC or DC position. 
See Figure 5.
2.  Place the red test lead from the test tool into 
the (+) terminal and press down rmly.
3.  Place the black test lead from the test tool 
into the (-) terminal and press down rmly. 
  The Product LED turns green and the T6 
display shows a 240 V measurement.
Battery Replacement
Push the nger ground contact button to check the 
battery condition. The nger ground contact LED 
turns green to show good battery condition. If the 
LED does not turn on, replace the batteries. 
 Warning
To prevent possible electrical shock, re, or 
personal injury:
 ●Do not operate the Product with covers 
removed or the case open. Hazardous 
voltage exposure is possible.
 ●Repair the Product before use if the battery 
leaks.
 ●Have an approved technician repair the 
Product.
To replace the batteries:
1.  Turn the battery-door latch until the unlock 
symbol aligns with the arrow. See Figure 2.
2.  Lift off the battery door.
3.  Insert or replace the four AA batteries. Use 
the correct battery orientation.
4.  Install the battery door.
5.  Turn the battery-door latch until the locked 
symbol aligns with the arrow.
Specications
Output voltage
240 V ac rms or dc ±10 %  ........... ≥1 MΩ
LED power indicator ......... Turns on when output voltage is 
present
Battery ................................... 4 x AA Alkaline batteries NEDA 
15 A IEC LR6
Battery life ............................. 3 hr based on a 10 s test cycle or 
1100 tests
Operating temperature ..... -10 °C to +50 °C
Operating humidity ........... 0 % to 90 % (0 °C to 35 °C)
0 % to 70 % (35 °C to 55 °C)
Operating altitude ............. 2000 m
Dimensions ....................... 11.7 cm x 7.4 cm x 4.5 cm
(4.6 in x 2.9 in x 1.75 in)
Weight ................................ 0.32 kg (12 oz) includes batteries
Safety
General IEC 61010-1, Pollution Degree 2 ............................
Measurement IEC 61010-2-030 ...................
240 Vrms/240 Vdc
Electromagnetic Compatibility (EMC)
  International IEC 61326-1: Controlled  ......................
Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses 
conductively-coupled radio frequency energy that is necessary 
for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments 
other than domestic and those directly connected to a low-
voltage power supply network that supplies buildings used 
for domestic purposes. There may be potential difculties in 
ensuring electromagnetic compatibility in other environments 
due to conducted and radiated disturbances. 
Caution: This equipment is not intended for use in residential 
environments and may not provide adequate protection to 
radio reception in such environments.
Emissions that exceed the levels required by CISPR 11 can 
occur when the equipment is connected to a test object.
Korea (KCC) Class A Equipment (Industrial  .......................
Broadcasting & Communication 
Equipment)
Class A: Equipment meets requirements for industrial 
electromagnetic wave equipment and the seller or user 
should take notice of it. This equipment is intended for use in 
business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This  ..........................
product is considered an exempt 
device per clause 15.103.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material 
and workmanship for one year from the date of purchase. 
This warranty does not cover fuses, disposable batteries, 
or damage from accident, neglect, misuse, alteration, 
contamination, or abnormal conditions of operation or 
handling. Resellers are not authorized to extend any other 
warranty on Fluke’s behalf. To obtain service during the 
warranty period, contact your nearest Fluke authorized service 
center to obtain return authorization information, then send 
the product to that Service Center with a description of the 
problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER 
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR 
PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT 
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR 
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM 
ANY CAUSE OR THEORY. Since some states or countries 
do not allow the exclusion or limitation of an implied warranty 
or of incidental or consequential damages, this limitation of 
liability may not apply to you.
Fluke Corporation Fluke Europe B.V.
P.O. Box 9090 P.O. Box 1186
Everett, WA  98206-9090 5602 BD Eindhoven
U.S.A. The Netherlands
11/99
Fluke Corporation certies this Product was tested and 
veried with applicable calibration procedures during the 
manufacturing process. Fluke’s quality system controls these 
procedures.
The instruments used during the testing and calibration of 
this Product are traceable to SI units through internationally 
recognized measurement standards.
This document is not a certicate of calibration or traceability.
To obtain a certicate of calibration contact the nearest 
Fluke service center to process an order to have your 
Product returned for calibration. A nominal fee is charged for 
calibration service.
Specyfikacje produktu
| Marka: | Fluke | 
| Kategoria: | nieskategoryzowany | 
| Model: | PRV240 | 
| Kolor produktu: | Black, Yellow | 
| Typ produktu: | Jednostka dowodzenia | 
| Ilość na paczkę: | 1 szt. | 
| Kompatybilność marki: | Fluke | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Fluke PRV240, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje nieskategoryzowany Fluke
                        
                         10 Lipca 2024
                        
                    
                                                            
                        
                         29 Maja 2024
                        
                    
                                                            
                        
                         26 Maja 2024
                        
                    
                                                            
                        
                         25 Maja 2024
                        
                    
                                                            
                        
                         25 Maja 2024
                        
                    
                                                            
                        
                         24 Maja 2024
                        
                    
                                                            
                        
                         22 Maja 2024
                        
                    
                                                            
                        
                         20 Maja 2024
                        
                    
                                                            
                        
                         19 Maja 2024
                        
                    
                                                            
                        
                         18 Maja 2024
                        
                    
                                                            Instrukcje nieskategoryzowany
- EVOline
 - OK
 - Cotek
 - HDFury
 - Gastronoma
 - Technaxx
 - GoldAir
 - Ixxat
 - Philips
 - Maestro
 - Aconatic
 - SEADA
 - Memphis Audio
 - TP-Link
 - Cyrus
 
Najnowsze instrukcje dla nieskategoryzowany
                        
                         28 Października 2024
                        
                    
                                                            
                        
                         28 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024
                        
                    
                                                            
                        
                         27 Października 2024