TABLE OF CONTENTS
1. Introduction
2. Quick start
3. Installation disclaimer
4. Connections
5. Installation
6. Factory reset
7. Startup
8. Principles of regulation
9. Waterbased heating/
electrical heating
10. Local settings menu
11. Display menu structure
12. Weekly schedule
13. Standby and main screen
14. Weekly schedule and
adapative function
15. Active power metering
values in menu
16. Size of load
17. Choice of sensor
18. Selecting sensor value
19. Calibration
20. Brightness
21. Display on/o
22. Display icons
23. Child lock
24. Open window detection
25. Anti-freeze function
26. Error codes
27. Safety features
28. Thermostat setpoint
29. Thermostat mode
30. Thermostat dimensions
31. Thermostat controls
32. Chart - display menu
Product info
1. INTRODUCTION
Heatit Pro is an electronic thermostat designed for electrical
heating, waterbased heating and cooling systems. The
thermostat has a user-friendly interface that can be controlled
from the buttons on the front of the thermostat.
Heatit Pro has 2 modes; Heat and Cool.
The thermostat fits in standard European junction boxes and
may be used with most System 55 frames. It has a sturdy metal
frame for secure fastening on the junction box. The thermostat
has one built-in room temperature sensor. Two additional
external temperature sensors may also be connected.
Heatit Pro has the option of a weekly program and open
window detection.
The product has implemented ZeroX technology. This
technology makes sure the relay switches at 0V when turning
on and o. With this technology the thermostat will have a
much longer lifetime.
Heatit Pro has active power metering, which allows the user to
see the real time power consumption.
The thermostat can withstand a load of max 16A/3600W at
230VAC. We recommend a contactor for loads above 13A.
2. QUICK START
1. Switch o the mains voltage (disable the fuse).
2. Open the junction box.
3. Connect the wires according to the description in
Chapter ”Connections”. Optional: Connect external wired
sensors.
4. After verifying the connections, switch on the mains voltage.
3. INSTALLATION DISCLAIMER
Installation must be done by a qualified electrician in
accordance with national building codes. Before installation,
disconnect the power to the device from the mains. During
installation of the device, power to the device must be
disconnected AT ALL TIMES!
4. CONNECTIONS
Max tightening torque for terminal screws: 2Nm.
If the cable used has multiple strands, using an end sleeve is
advised. The product allows for wiring of cables with a cross
section of up to 1x2.5mm.
The screw terminals are located at the back of the device, and
are accessable at all times.
PRODUCT
DOCUMENTS
HEATIT
PRO
Installers manual
Firmware version Document version
FW 1.0 2024-A
Article no. Document date
54 305 81
54 305 82
54 305 83
01.07.2024
Org. doc. date 01.07.2024
White RAL 9003 White RAL 9010
54 305 82 54 305 81
Black matt
54 305 83


Specyfikacje produktu

Marka: Heatit
Kategoria: termostat
Model: PRO

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Heatit PRO, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje termostat Heatit

Heatit

Heatit Z-Temp3 Instrukcja

3 Stycznia 2025
Heatit

Heatit PRO Instrukcja

9 Października 2024
Heatit

Heatit MULTIREG6 Instrukcja

9 Października 2024
Heatit

Heatit WiFi6 Instrukcja

7 Października 2024
Heatit

Heatit Z-TRM6 DC Instrukcja

7 Października 2024
Heatit

Heatit WiFi Instrukcja

7 Października 2024
Heatit

Heatit Z-Wave Plus Instrukcja

13 Września 2024
Heatit

Heatit Z-TRM3 Instrukcja

28 Sierpnia 2024
Heatit

Heatit Z-Wave Instrukcja

27 Sierpnia 2024

Instrukcje termostat

Najnowsze instrukcje dla termostat