Instrukcja obsługi Hikvision DS-PDCL12DT-EG2

Hikvision system alarmowy DS-PDCL12DT-EG2

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Hikvision DS-PDCL12DT-EG2 (9 stron) w kategorii system alarmowy. Ta instrukcja była pomocna dla 19 osób i została oceniona przez 6 użytkowników na średnio 4.0 gwiazdek

Strona 1/9
Wired Dual Technology Ceiling Detector
DS-PDCL12DT-EG2
User Manual
EN 50131-2-4:2020
EN 50131-1+A1+A2+A3
Environment ClassII
Security Grade2
Testedby TÜVRheinland
HangzhouHikvision DigitalTechnology CO.,Ltd.No.555 QianmoRoad, BinjiangDistrict, Hangzhou310052, China
UD26464B-B
2
4 5
3
1
120.0 mm
33.2 mm
1
1
1
11
3
3
3
33
2
2
2
22 a
a
a
aa
a
a
a
aa
c
c
c
cc
b
b
b
bb
b
b
b
bb
=
=
4K7
2K2
1K
5K6
ALARM +
-
EOL
TAMPER
EOL
2.2K
4K7
2K2
1K
5K6
6K8
ALARM +-
EOL
TAMPER
EOL
2.2K
ALARM
KA3 × 25
TAMPER
COM
ZONE1
COM
+-
ALARMTAMPER +-
6K8
5K6
4K7
2K2
1K
5K6
4K7
2K2
1K
ALARMTAMPER
EOLEOL
2.2K 2.2K
ZONE2
ZONE2
COM
ZONE1
COM
+-
ALARMTAMPER +-
6K8
5K6
4K7
2K2
1K
5K6
4K7
2K2
1K
ALARMTAMPER
EOLEOL
ZONE2
COM
ZONE1
COM
+-
ALARMTAMPER +-
6K8
5K6
4K7
2K2
1K
5K6
4K7
2K2
1K
ALARMTAMPER
EOLEOL
1
2
6
7
8
9
8m
10m
12m
2.4m 3m 4m
6m
6m
6m
6m
4m
4m
4m
4m
2m
2m
2m
2m
0m
0m
Zone:172 Plane:3
English
5
6
Specification
Please usethe power suppliescomply with the requirements ofEN
50131-6 atthe appropriategrade and environmental class.
Please usethe power adaptercomplianting with LPS.The recommended
power adapterismadeby ShenzhenHonorElectronic Co.,Ltd.
Please donot obscure thedetectors field of viewpartially or
completely.
Method 1:Use the jumpertoselect EOL(Endof Line) resistanceon
TAMPER/ALARMEOL pins.
Method 2:Add the resistorto TAMPER/ALARMwiring ports.
Note:If EOLwiringis notused,leave thejumpersOFF. Donotforce the
jumperif itisnotmatched thepin.Method 1&2should notbeusedon
the ALARM/TAMPERatthe same time.
a. AlarmResistance: 1K,2K2, 4K7, 5K6, 6K8
b. Tamper Resistance: 1K, 2K2, 4K7,5K6
Connection Type
Note:The resistormust beconnectedin serieswithoneend ofthe
detector.
a.Normally Closed
b.Single Endof Line Wiring
c.Double EndofLine Wiring
Detection Range
Powering On
After poweringon, the indicator flashesrapidly.Once the detector self
test iscompleted,the LEDindicatorwill gooutuntil thedetectordetects
movement.
Appearance
1. PIRsensitivity jumper2. LEDjumper3. Alarm EOLpin4. Terminals
5. TamperEOLpin6. Tamper7. PIRsensor8. LED indicator
9.Microwave sensor
Installation
Resistor Wiring
Relay Status
Normal
Close
Close
PIR& MicrowaveAlarm
Open
Close
PIR Fault
Open
Close
Microwave Fault
Close
Close
Tamper
Close
Open
Alarm Relay
Detection methodPassive Infrared,Microwave
Detection range12 m
Detection angle360°
Detection zones172
Detectable speed0.3 to2 m/s
SensitivityAuto, Low
White lightfilter6500 lux
Microwavefrequency24 GHz (24.15 to24.25 GHz)
Digitaltemperaturecompensation Support
Creep zone protectionSupport
Digital processingSupport
Sealed opticsSupport
Tamper protectionFront
LED indicatorGreen(PIR), Red(Microwave),
Blue(Alarm)
Power consumption100 mA Max
Powersupply9 to 16 VDC
Typical voltage12 VDC
Operationtemperature-10°Cto 55 °C (14 °Fto 131 °F)
Storage temperature-20°Cto 60 °C (-4 °Fto140 °F)
Operation humidity10%to 90%
Dimensionφ120 mmx 33.2 mm
Weight138 g
Mounting height2.4 to4 m
Mounting methodCeiling
Application scenarioIndoor
Tamper Relay
LOW
AUTO (Default)
LED ON
LED OFF
1K, 2K2,
4K7, 5K6, 6K8
3
1K,2K2,
4K7,5K6
4
5

Oceń tę instrukcję

4.0/5 (6 Recenzje)

Specyfikacje produktu

Marka: Hikvision
Kategoria: system alarmowy
Model: DS-PDCL12DT-EG2

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Hikvision DS-PDCL12DT-EG2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą