Instrukcja obsługi IFM OGH502


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla IFM OGH502 (4 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 10 osób i została oceniona przez 5.5 użytkowników na średnio 3.7 gwiazdek

Strona 1/4
Operating instructions
Diffuse reflection sensor
with background suppression
OGH3xx
OGH5xx
UK
704073 / 03 11 / 2019
2
1 Functions and features
The diffuse reflection sensor detects objects and materials without contact and
indicates their presence by a switching signal.
For the range see the type label (on white paper 200x200 mm, 90 % remission).
2 Installation
Align the diffuse reflection sensor to the object to be detected.
Secure the unit to a bracket.
The objects to be detected are to move
transversally to the lens of the sensor.
In case of other directions of movement it
should be tested before whether the swit-
ching function is guaranteed.
3 Electrical connection
Disconnect power.
Connect the unit as follows.
Cable Connector Pin connection
L+ BN pin 1
L- BU pin 3
load BK pin 4
load *) WH *) pin 2 *)
Core colours BN = brown, BU = blue, BK = black
*) Seulement pour des appareils avec sortie antivalente.
UK
3
4 Operating and display elements
 
1: LED
2: [OUT o󰀨]
3: [OUT on]
4 Settings
4.1 The sensor is to switch when the object is detected
1
Position the object.
► Press [OUT on] for 2 s.
> The sensitivity is set to the object.
> The LED flashes.
2
Remove the object.
► Press [OUT off].
> The sensitivity is set without object.
> The LED goes out. The programming is finished.
4.2 The sensor is not to switch when the object is detected
► Position the object (see figure 1) and press [OUT off] for 2
s.
► Remove the object (see figure 2) and press [OUT on].
The settings can also be carried out first without object and then with object.