Installation instructions
Electronic absolute pressure sensor
for industrial applications
PT05xx
14154628 02 / 2016
UK

2
1 Preliminary note
Symbols used
►Instructions
→Cross-reference
Important note
Non-compliance can result in malfunction or interference.
Information
Supplementary note.
2 Safety instructions
• Please read this document prior to set-up of the unit. Ensure that the product is
suitable for your application without any restrictions.
• If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property can occur.
• Improper or non-intended use may lead to malfunctions of the unit or to
unwanted effects in your application. That is why installation, electrical
connection, set-up, operation and maintenance of the unit must only be carried
out by qualified personnel authorised by the machine operator.
• In order to guarantee the correct condition of the device for the operating time it
is necessary to use the device only for media to which the wetted materials are
sufficiently resistant (→ Technical data).
Contents
1 Preliminary note 2 ...................................................................................................
2 Safety instructions 2 ...............................................................................................
3 Functions and features 3 ........................................................................................
3.1 Applications ...................................................................................................3
4 Functions .............................................................................................................4
5 Installation............................................................................................................4
6 Electrical connection 5 ............................................................................................

3
UK
• The responsibility whether the measurement devices are suitable for the
respective application lies with the operator. The manufacturer assumes no
liability for consequences of misuse by the operator. Improper installation and
use of the devices result in a loss of the warranty claims.
3 Functions and features
The pressure sensor detects the system pressure and converts it into an analogue
output signal.
3.1 Applications
• Type of pressure: absolute pressure
You can find the technical data such as measuring range, pressure rating
and bursting pressure in the corresponding technical data sheet → www.
ifm.com.
Avoid static and dynamic overpressure exceeding the specified overload
pressure by taking appropriate measures.
The indicated bursting pressure must not be exceeded.
Even if the bursting pressure is exceeded only for a short time, the unit
may be destroyed. ATTENTION: Risk of injury!
Pressure Equipment Directive (PED):
Units are comply with the Pressure Equipment Directive and are designed
and manufactured for group 2 fluids in accordance with the sound
engineering practice.
Use of group 1 fluids on request!
Specyfikacje produktu
Marka: | IFM |
Kategoria: | Niesklasyfikowane |
Model: | PT0504 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z IFM PT0504, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane IFM
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
Instrukcje Niesklasyfikowane
- Niesklasyfikowane Overtone Labs
- Niesklasyfikowane Peltor
- Niesklasyfikowane Gardenline
- Niesklasyfikowane Moldex
- Niesklasyfikowane Lexivon
- Niesklasyfikowane Satel
- Niesklasyfikowane Zenza Bronica
- Niesklasyfikowane Crazy Tube Circuits
- Niesklasyfikowane Novation
- Niesklasyfikowane J.P. Instruments
- Niesklasyfikowane Sinus Live
- Niesklasyfikowane Seymour Duncan
- Niesklasyfikowane Billow
- Niesklasyfikowane Brinsea
- Niesklasyfikowane JAR Systems
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025