Wireless thermostat TP-98  - 2 -  MFR51500 
 Wireless thermostat TP-98 
This thermostat can replace a common indoor residential thermostat. It 
is designed to be used with electric, gas or oil heating system. The 
easy to read display shows the current room temperature and 
temperature adjustment is very simple. The main advantage is that 
there is no need of a cable between the thermostat and the heating 
system. 
Installation 
 The TP-98TX should be mounted 
in a dry indoor location. Choose a 
mounting location about 1.5 meters 
above the floor in the area with 
good air circulation. Avoid places 
with drafts, dead air spots and 
radiant heat from the sun or 
appliances. It should not be 
installed close to any metal 
structure or other objects that may 
obstruct radio signal transmissions. 
1.  Remove the front housing of the thermostat. (using a screwdriver)  
2.  Insert the batteries. Current temperature will appear on the display if 
not check the batteries. 
3.  Attach the thermostat to the wall with the two screws. 
Mounting the receiver unit 
Place the receiver unit in a suitable place near the heater. Wiring 
of the unit to the heater should be done only by a professional 
electrician: 
1.  Release the upper cover by pressing the plastic log on the top side 
of housing. 
2.  Release the internal cover (1 screw). 
3.  Mount the unit to the desired location (2 screws). 
4.  Connect power 230VAC / 50Hz to terminals L and N. 
5.  Two PE terminals are available for a protective earth connection. 
6.  Terminals C (common), N.O. (normally open) and N.C. (normally 
closed) are outputs of the relay contact. This contact is protected by 
a 6.3A fuse. The contacts are galvanic separated. 
 Note: The 
thermostat, which 
has a unique code, 
is enrolled to the 
receiver unit from 
the factory. 
A built-in LED 
indicator indicates a 
status of the output 
relay. 
TEMPERATURE SETTING 
In the normal operation mode the thermostat shows the room 
temperature. To set a desired temperature: 
1.  Press   or   button to view the set temperature. The sign SET 
will appear on the display. 
2.  Hold   or   button for approximately 3 seconds till the 
temperature indicator will flash once.  
3.  Use   or   button to increase or decrease the temperature 
setting. If no button is pressed for 10 seconds the unit will be 
switched back to the normal operation mode. 
The programmed temperature range is from 5˚C to 35˚C. 
The temperature span between switching ON and OFF is 1˚C. For 
example, if the temperature setting is 20˚C, the heater will be switched 
on when the room temperature drops to 19.5˚C and will be switched off 
when the temperature rises to 20.5˚C. When the thermostat is on the 
symbol HEAT will be shown on the display. 
When the temperature is above 40˚C ‘HI’ will be shown on the LCD 
and ‘LO’ will be shown when temperature falls below 0˚C. 
When the voltage of the batteries is low the LCD will be turned off. In 
that case the batteries should be changed. 
Enrolment of the thermostat into the receiver unit 
The thermostat has already been enrolled to the receiving unit in 
the factory. If you change the thermostat for a new one it must be 
enrolled to the receiver unit in the following way: 
1.  Remove the batteries from the thermostat for 2 minutes.  
2.  Remove the upper housing from the receiver unit. 
3.  Keep pressing the button inside the receiver until the 4th LED starts 
flashing.  
4.  Place the batteries into the thermostat. The LEDs in the receiver will 
flash once to confirm the enrolment. 
Note:  Each receiver unit can cooperate only with one thermostat. If any 
other device (remote control etc.) has been enrolled to the receiver the 
receiver must be reset before enrolment of the thermostat. To reset the 
memory make the 4th LED flashing by pressing the button and then 
press and hold the button until all LEDs flash rapidly.  
Specifications 
Thermostat TP-98TX 
Power Source:  two AAA 1.5V Alkaline batteries 
Temperature Measurement:  0 - 40˚C 
Temperature Accuracy:            ±1.0˚C 
Temperature Control:  5 - 35˚C 
Temperature Control Span:  0,5˚C 
Output On Delay:  20 seconds 
Working frequency  433,92 MHz 
Working distance  up to 100 m (open area) 
Coding:  digital, each thermostat has a unique       
floating code 
Operating Temperature:  -10˚C to 50˚C (non-condensing) 
Storage Temperature:               -30˚C to 60˚C 
Size:  73.5 X  28.0 X  73.5 mm 
Housing: Polycarbonate (PC) 
Weight:  90 g (battery not included) 
Receiver unit UC-222 
Voltage:  230 V AC 
Power consumption:  max. 1 W 
Operating frequency:  433.92 MHz 
Coding:  digital, each thermostat has  
  a unique floating code 
Output relay:  over switching dry contact 
  Fused 6 A at 250 V 
Can be operated according to ERC REC 70-03 
Hereby, Jablotron Ltd., declares that this TP-98 is in compliance with 
the essential requirements and other relevant provisions of Directive 
1999/5/EC. 
Note: Dispose of batteries safely depending on the type of the 
batteries and local regulation. Although this product does not contain 
any harmful materials we suggest you to return the product to the 
dealer or directly to the producer after usage. 
2
1
3
4
Relé 
Specyfikacje produktu
| Marka: | Jablotron | 
| Kategoria: | termostat | 
| Model: | TP-98 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Jablotron TP-98, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje termostat Jablotron
                        
                         7 Kwietnia 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         30 Stycznia 2025
                        
                    
                                                            Instrukcje termostat
- BaseTech
- Theben
- EQ-3
- Devolo
- ELV
- Energenie
- BTicino
- Oregon Scientific
- Hoffman
- Bosch
- Mikoterm
- ATTACK
- Coati
- Extraflame
- GENERAL Life
Najnowsze instrukcje dla termostat
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         7 Kwietnia 2025
                        
                    
                                                            
                        
                         6 Kwietnia 2025
                        
                    
                                                            
                        
                         6 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025