INSTRUCTION MANUAL
DIGITALCLAMPMETER
KEW2007R
1. Safety Warnings
Thisinstrumenthasbeendesigned,manufacturedand
testedaccordingtoIEC61010:Safetyrequirementsfor
Electronicmeasuringapparatus,anddeliveredinthebest
conditionafterpassedtheinspection.Thisinstruction
manualcontainswarningsandsafetyruleswhichmustbe
observedbytheusertoensuresafeoperationofthe
instrumentandretainitinsafecondition.Therefore,read
throughtheseoperatinginstructionsbeforeusingthe
instrument.
WARNING
● Read through and understand the instructions contained
in this manual before usingthe instrument.
● Keep the manual at hand to enable quick reference
whenever necessary.
● The instrument is to be used only in its intended
applications.
● Understand and follow all the safety instructions
contained in themanual.
● It is essential that the above instructions are adhered to.
Failure to followthe above instructions may impair the
protection providedby the instrument andtest leads, and
may cause injury, instrument damage and/or damage to
equipment under test.
The symbolindicatedonthe instrumentmeansthatthe
usermustrefertotherelatedpartsinthemanualforsafe
operationoftheinstrument.Itisessentialtoreadthe
instructions wherever the symbolappears in the manual.
DANGER is reserved for conditionsand actions that
are likely to cause serious or fatal injury.
WARNING is reservedfor conditions and actions that
can cause seriousor fatal injury.
CAUTION is reserved for conditionsand actions that
can cause injuryor instrument damage.
● Marks listed below are used on this instrument.
User must refer to the manual.
Instrument with double or reinforced insulation
Indicates that this instrument can clamp on
bare conductorswhen measuring a voltage
corresponding to the applicable measurement
category, which ismarked next to this symbol.
ACDCGround (Earth)
This instrument is subject to WEEE Directive
(2002/96/EC). Please contact our dealer near
you at disposal.
Measurement Category
OCircuitswhich are notdirectly connected to the mains
power supply.
CAT IIPrimary electrical circuits of equipment connected
to anAC electrical outlet by a powercord.
CAT IIIPrimary electrical circuits of the equipment
connecteddirectlytothedistributionpanel,andfeeders
from the distribution panel to outlets.
CAT IV The circuitfrom the servicedrop to the service
entrance, and to the power meter and primary over current
protection device(distribution panel).
ThisinstrumentisdesignedforCATIV300V/CATIII
600V.TestleadsM-7066Awiththesuppliedcapare
designedforCATIV600V/CATIII1000Vandwithout
the caps are for CAT II1000V.
DANGER
● Never make measurements under the circumstances
exceed thedesigned measurementcategory andthe
ratedvoltage of the instrument andthetest leads.
● Do not attempt to make measurement in the presence of
flammable gasses.Otherwise, the use of the instrument
may cause sparking, which can lead to an explosion.
● Never attempt to use the instrument if its surface or your
hand is wet.
● Do not exceed the maximum allowable input of any
measuring range.
● Never open the Battery cover during a measurement.
● To avoid electrical shock by touching the equipment
under test or its surroundings, be sure to wear insulated
protective gear.
● Never measure current while the test leads are inserted
into the input terminals.
● Test leads to be used for voltage measurements shall be
ratedas appropriate for Measurement Category IIIor IV
according to IEC 61010-031 andshall have a voltage
ratingof 600V or higher.
● Barriers on the instrument body and the test leads
provide protection to keepyour fingers andhands from
touching an object under test. Keep your fingersand
hands behind the barriers during measurement.
WARNING
● Never attempt to make measurement if any abnormal
conditions, such asbroken case and exposedmetal
parts are found on the instrument or test leads.
● Verify proper operation on a known source before use or
take action as a result ofthe indication of the instrument.
● Firmly attach the caps to the test leads when
performing measurements in CAT III or higher test
environments. When KEW2007R and the test leads
arecombined and used together, whichever is lower
category & voltage to earth either of them belong to
is applied.
● Do not rotate the Function Switch if the instrument and
the equipment under test are connected.
● Do not install substitute parts or make any modification to
the instrument.For repair or re-calibration, return the
instrument toyour local KYORITSU distributor
CAUTION
● Use of this instrument is limited to domestic, commercial
and light industry applications. Strong electromagnetic
interference or strongmagnetic fields, generatedby
large currents, may cause malfunction of the instrument.
● Connect the test leads to the terminals firmly.
● This instrument isn’t water proofed. Keep away from
water.
● Do not pull or twist the test leads to prevent the risk of
damage.
● Power off the instrument after use. Remove batteries if
the instrument is to be stored andwill not be in use for a
long period.
● Do not expose the instrument to the direct sunlight, high
temperature andhumidity or dewfall.
● Use a cloth dipped in water or neutral detergent for
cleaning theinstrument. Do not use abrasives orsolvents.
NOTE
● The LCD shows some digits at the ACV and the DCV
ranges even while the test leads are open. In addition,
the LCD shows some digits instead of 0 when short-
circuiting the test leads. However, these phenomena
don’t affect measurement results.
2. Specification
Temperature: 23 ± 5°C, Humidity: 45 - 75%
ACA(Auto-range)
RangeDisplay RangeAccuracy (sinewave)*1
600A0.0, 0.4-629.9A ±1.5 %rdg±4dgt(45-65Hz)
±2.0 %rdg±4dgt(40-400Hz)
1000A570-1049A
*1 : whenthemeasured conductoris inthecenter ofclamp jaw
Guaranteed accuracy : 0.8A -1000A,less than 1500APeak
Input protective current :AC1200A
ACV
RangeDisplay RangeAccuracy (sine wave)
600V0.0, 0.6-629.9V ±1.2 %rdg±3dgt(45-65Hz)
±1.5 %rdg±4dgt(40-400Hz)
Guaranteed accuracy : 1.0V - 600.0V,less than 900V Peak
Input protective voltage:AC/DC720V 10 sec
DCV
RangeDisplay RangeAccuracy
600V0.0-±629.9V±1.2%rdg±3dgt
Guaranteed accuracy : 0.0V - ± 600.0V
Input protective voltage:AC/DC720V 10 sec
ACV/DCV input impedance : approx. 10MΩ
Resistance / Continuity(Auto-range)
RangeDisplay RangeAccuracy
600Ω 0.0-629.9 Ω ±1.3%rdg±5dgt
6kΩ 0.570-6.299 kΩ±2.0%rdg±3dgt
Cont. 0.0-629.9 Ω Bz threshold value <90Ω
Guaranteed accuracy : 0.0Ω - 6.000kΩ
Open-loop voltage : 3Vor less
Input protective voltage:AC/DC600V 10 sec
●Measuring method : ⊿Σ modulation
●Over-range indication : OL
●Measurement cycle : 2.5 times per second
●Crest factor : less than 3 (45-65Hz)
Add ±0.5%rdg±5dgt to above specified accuracies.
(Applicable functions :ACA,ACV)
●Applicable Standards :
IEC 61010-1/ 61010-2-032/ 61010-2-033 (instrument)
Pollutiondegree 2, Indoor use, Altitude upto 2000m
CAT III 600V / CAT IV 300V
IEC 61010-031(TestleadsModel 7066A)
w/capsCAT IV 600V / CAT III 1000V
w/o capsCAT II1000V
IEC61326 (EMC),EN50581(RoHS)
●Withstand voltage : AC5160Vrms 5sec
between current sensor and enclosure or
circuit and enclosure
●IP rating : IP40 (IEC60529)
●Insulation resistance :
>100MΩ /1000V between enclosure and electrical circuit
Function
Switch
Current Sensor
Hold Key
LCD
V/Ω
Terminal
COM
Terminal
Trigger
Cap
Barrier ofTest Leads
Barrier
Wrist Strap
Specyfikacje produktu
| Marka: | Kyoritsu |
| Kategoria: | multimetr |
| Model: | KEW2007R |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Kyoritsu KEW2007R, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje multimetr Kyoritsu
14 Stycznia 2025
14 Grudnia 2024
14 Grudnia 2024
14 Grudnia 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
Instrukcje multimetr
Najnowsze instrukcje dla multimetr
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
28 Marca 2025
26 Marca 2025
14 Marca 2025