Instrukcja obsługi LiftMaster LMRRUL


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla LiftMaster LMRRUL (16 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 25 osób i została oceniona przez 13 użytkowników na średnio 4.9 gwiazdek

Strona 1/16
Introduction
The LiftMaster® Retro-Refl ective Photoelectric
Sensor provides non-contact monitored entrapment
protection. For use with LiftMaster® UL Listed
gate operators. The sensor is a UL Recognized
Component and meets UL 325 requirements.
Monitored external entrapment protection devices
MUST be installed at each Entrapment Zone. Refer to
gate operator manual for compatibility with LMRRUL
sensor.
Speci cations
Max Range: 50 ft. (15.2 m)
Sensor Dimensions with Hood:
2.29" W x 3.72" H x 2.76" D
Refl ector Dimensions with Hood:
2.61" W x 4.72" H x 2" D
Cable Length: 10 ft. (3 m)
Operating Temperature: -40˚C to 65˚C
(-40˚F a 149˚F)
Outdoor Rating: Nema 4X
Input voltage:
Sensor: Black/red wires 6.8 VDC, 20mA
Heater: Green/white wires 10-40VDC or 8-28 VAC, 2
watts max., 170mA @ 12 VDC/VAC,
85mA@ 24 VDC/VAC
Heater: Thermostatically controlled, NOT
recommended for solar applications
MONITORED RETRO-REFLECTIVE
PHOTOELECTRIC SENSOR
Model LMRRUL
To prevent possible SERIOUS INJURY or DEATH from a closing gate or door:
Read and follow ALL instructions.
Be sure to DISCONNECT ALL POWER to the operator BEFORE installing the photoelectric sensor.
The gate or door MUST be in the fully opened or closed position BEFORE installing the LiftMaster®
Monitored Entrapment Protection device.
Correctly connect and align the photoelectric sensor.
Install the photoelectric sensor so that the center of the sensor window is NO HIGHER than
4-1/2" (11.4cm) above the oor for door operators and 26" (66 cm) above grade for gate operators.
Monitored external entrapment protection devices MUST be installed per the operator installation
manual at each Entrapment Zone.
The sensor and refl ector MUST be mounted vertically.
Use the provided refl ector ONLY.
Test the gate operator and ALL photoelectric sensors monthly. Replace ANY damaged devices.
SAVE THESE INSTRUCTIONS.
WARNING: This product can expose you to chemicals including lead, which are known
to the State of California to cause cancer or birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov.


Specyfikacje produktu

Marka: LiftMaster
Kategoria: Niesklasyfikowane
Model: LMRRUL

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z LiftMaster LMRRUL, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane LiftMaster

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

SmallRig

SmallRig VB99 SE Instrukcja

29 Stycznia 2025
QSC

QSC TSC-8 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5130 Instrukcja

29 Stycznia 2025
Sunding

Sunding SD-581G Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5070 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS2010 Instrukcja

29 Stycznia 2025
OSEE

OSEE TX402 Instrukcja

29 Stycznia 2025