Instrukcja obsługi Microchip MCP3905


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Microchip MCP3905 (30 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 9 osób i została oceniona przez 5 użytkowników na średnio 4.7 gwiazdek

Strona 1/30
© 2009 Microchip Technology Inc. DS21948E-page 1
MCP3905/06
Features
Supplies active (real) power measurement for
single-phase, residential energy-metering
Supports the IEC 62053 International Energy
Metering Specification and legacy IEC 1036/
61036/687 Specifications
Two multi-bit, Digital-to-Analog Converters
(DACs), second-order, 16-bit, Delta-Sigma
Analog-to-Digital Converters (ADCs)
0.1% typical measurement error over 500:1
dynamic range (MCP3905)
0.1% typical measurement error over 1000:1
dynamic range (MCP3906)
Programmable Gain Amplifier (PGA) for small-
signal inputs supports low-value shunt current
sensor
-16:1 PGA - MCP3905
-32:1 PGA - MCP3906
Ultra-low drift on-chip reference: 15 ppm/°C
(typical)
Direct drive for electromagnetic mechanical
counter and two-phase stepper motors
Low IDD of 4 mA (typical)
Tamper output pin for negative power indication
Industrial Temperature Range: -40°C to +85°C
Supplies instantaneous active (real) power on
HFOUT for meter calibration
US Patents Pending
Description
The MCP3905/06 devices are energy-metering ICs
designed to support the IEC 62053 International
Metering Standard Specification. They supply a
frequency output proportional to the average active
(real) power, as well as a higher-frequency output
proportional to the instantaneous power for meter
calibration. They include two 16-bit, delta-sigma ADCs
for a wide range of IB and IMAX currents and/or small
shunt (< 200 µOhms) meter designs. It includes an
ultra-low drift voltage reference with < 15 ppm/°C
through a specially designed band gap temperature
curve for the minimum gradient across the industrial
temperature range. A fixed-function DSP block is
on-chip for active (real) power calculation. Strong
output drive for mechanical counters are on-chip to
reduce field failures and mechanical counter sticking. A
no-load threshold block prevents any current creep
measurements. A Power-On Reset (POR) block
restricts meter performance during low-voltage
situations. These accurate energy-metering ICs with
high field reliability are available in the industry-
standard pinout.
Package Type
Functional Block Diagram
FOUT0
DGND
NEG
1
2
3
4
24
23
22
21
20
19
18
17
5
6
7
8
FOUT1
NC
OSC2
OSC1
DVDD
HPF
AVDD
NC
CH0+
CH0-
CH1-
CH1+
HFOUT
16
9G0
MCLR
15
14
10
11
G1
F0
REFIN/OUT
AGND
1312 F1
F2
24-Pin SSOP
16-bit
ΔΣ ADC
MCLR
+
CH0+
CH0-
Reference
2.4V
+
CH1+
CH1-
HPF1
LPF1 E-to-F
conversion
REFIN/
FOUT1
HFOUT
G0 G1
F2 F1
FOUT0
OSC1 OSC2
OUT
NEG
HPF
F0
Multi-level
16-bit
ΔΣ ADC
Multi-level
X
HPF1
PGA
POR
Energy-Metering ICs with Active (Real) Power Pulse Output
Obsolete Device
Replacement Device:
MCP3905A/MCP3906A


Specyfikacje produktu

Marka: Microchip
Kategoria: Niesklasyfikowane
Model: MCP3905

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Microchip MCP3905, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Microchip

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

SmallRig

SmallRig VB99 SE Instrukcja

29 Stycznia 2025
QSC

QSC TSC-8 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5130 Instrukcja

29 Stycznia 2025
Sunding

Sunding SD-581G Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5070 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS2010 Instrukcja

29 Stycznia 2025
OSEE

OSEE TX402 Instrukcja

29 Stycznia 2025