Introduction
Thank you for purchasing the OMRON® BP742N Blood Pressure Monitor.
Your new blood pressure monitor uses the oscillometric method of blood pressure 
measurement. This means the monitor detects your blood movement through your 
brachial artery and converts the movements into a digital reading. An oscillometric 
monitor does not need a stethoscope so the monitor is simple to use.
Intended Use
This device is a digital monitor intended for use in measuring blood pressure and 
pulse rate in adult patient population who can understand this instruction manual 
with the arm circumference range printed on the arm cuff. The device detects the 
appearance of irregular heartbeats during measurement and gives a warning signal 
with the measurement result.
Please read this instruction manual thoroughly before using the device.
Please keep for future reference. For specific information about your own blood 
pressure, CONSULT YOUR PHYSICIAN.
Important Safety Information
Warning: Indicates a potentially hazardous situation which, if not avoided, 
could result in death or serious injury.
(General Usage)
DO NOT adjust medication based on measurement results from this blood 
pressure monitor. Take medication as prescribed by your physician. Only a 
physician is qualified to diagnose and treat High Blood Pressure.
This device is not intended to be a diagnostic device.
Consult your physician before using the device in pregnancy including 
pre-eclampsia, or if diagnosed with arrhythmia or arteriosclerosis.
Do not use the device on the injured arm or the arm under medical treatment.
Do not apply the arm cuff on the arm while being on an intravenous drip or blood 
transfusion.
Consult your physician before using the device on the arm with an arterio-venous 
(A-V) shunt.
Do not use the device with other medical electrical (ME) equipment 
simultaneously.
Do not use the device in the area the HF surgical equipment, MRI, or CT scanner 
exists, or in the oxygen rich environment.
The air tube or the AC adapter cable may cause accidental strangulation in 
infants.
Contained small parts that may cause a choking hazard if swallowed by infants.
(AC Adapter (optional) Usage) 
Do not use the AC adapter if the device or the power cord is damaged. Turn off 
the power and unplug the power cord immediately. 
Plug the AC adapter into the appropriate voltage outlet. Do not use in a 
multi-outlet plug.
Never plug in or unplug the power cord from the electric outlet with wet hands.
Caution: Indicates a potentially hazardous situation which, if not avoided, 
may result in minor or moderate injury to the user or patient or 
damage to the equipment or other property.
(General Usage)
Always consult your physician. Self-diagnosis of measurement results and 
self-treatment are dangerous.
People with severe blood flow problems, or blood disorders, should consult a 
physician before using the device, as the arm cuff inflation can cause bruising.
Remove the arm cuff if it does not start deflating during the measurement.
Do not use this device on infants or persons who cannot express their intentions.
Do not use the device for any purpose other than measuring blood pressure.
Use only the approved arm cuff for this device. Use of other arm cuffs may result 
in incorrect measurement results.
Do not use a mobile phone or other devices that emit electromagnetic fields, 
near the device. This may result in incorrect operation of the device.
Do not disassemble the monitor or arm cuff. This may cause an inaccurate 
reading.
Do not use in a location with moisture, or a location where water may splash on 
the device. This may damage the device.
Do not use the device in a moving vehicle (car, airplane).
Do not take measurements more than necessary. It may cause bruising due to 
blood flow interference.
Consult your physician before using the device if you had a mastectomy.
Read "If your systolic pressure is more than 210 mmHg" of this instruction 
manual, if your systolic pressure is known to be more than 210 mmHg. Inflating 
to a higher pressure than necessary may result in bruising where the arm cuff is 
applied.
(AC Adapter (optional) Usage)
Fully insert the power plug into the outlet.
When disconnecting the power plug from the outlet, do not pull the power cord. 
Be sure to pull from the power plug safely.
When handling the power cord, take care not to do the following:
Wipe the dust off from the power plug.
Unplug monitor when not in use.
Disconnect the power plug before cleaning.
Use only an OMRON AC adapter designed for this device. Use of unsupported 
adapters may damage and/or may be hazardous to the device.
(Battery Usage)
Do not insert the batteries with their polarities incorrectly aligned.
Use only 4 “AA” alkaline or manganese batteries with this device. Do not use 
other types of batteries. Do not use new and used batteries together.
Remove the batteries if the device will not be used for three months or more.
General Precautions
• Do not forcibly crease the arm cuff or the air tube excessively.
• Do not press the air tube while taking a measurement.
• To unplug the air plug, pull on the air plug at the connection with the monitor, not 
the tube itself.
• Do not drop the monitor or subject device to strong shocks or vibrations.
• Do not inflate the arm cuff when it is not wrapped around your arm.
• Do not use the device outside the specified environment. It may cause an 
inaccurate reading.
• Dispose of the device, components and optional accessories according to 
applicable local regulations. Unlawful disposal may cause environmental pollution.
1. Know Your Device
Contents:
Monitor, arm cuff, battery set, instruction manual, quick start guide
Monitor:
Arm cuff:
Display:
1.1 Display symbols
Irregular Heartbeat Symbol ( )
When the monitor detects an irregular 
rhythm two or more times during the 
measurement, the irregular heartbeat 
symbol ( ) will appear on the display 
with the measurement values. 
An irregular heartbeat rhythm is defined 
as a rhythm that is 25% less or 25% 
more than the average rhythm detected 
while the monitor is measuring the systolic and diastolic blood pressure. 
If the irregular heartbeat symbol ( ) displays with your measurement results, 
we recommend you consult your physician. Follow the directions of your 
physician.
Movement Error Symbol ( )
The movement error symbol is displayed if you move your body during the 
measurement. Please remove the arm cuff, and wait 2 - 3 minutes. 
Take another measurement, remain still during measurement.
Average Value Symbol ( )
The average value symbol is displayed when you press and hold the memory 
button for more than 3 seconds. The most recent average value appears on 
the display screen.
Blood Pressure Level Indicator
2013 ESH/ESC Guidelines for the management of arterial hypertension
Definitions of hypertension by office and home blood pressure levels
These are from statistical values for blood pressure.
1.2 Before Taking a Measurement
To help ensure an accurate reading, follow these directions:
1. Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating 
for 30 minutes before taking a measurement. Rest for at least 15 minutes 
before taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful 
times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your arm.
5. Sit on a chair with your feet flat on the floor. Rest your arm on a table so 
that the arm cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your 
physician. A single measurement does not provide an accurate indication of 
your true blood pressure. You need to take and record several readings 
over a period of time. Try to measure your blood pressure at the same time 
each day for consistency.
2. Preparation
2.1 Battery Installation
1. Remove the battery cover.
2. Insert 4 “AA” batteries as 
indicated in the battery 
compartment.
3. Replace the battery cover.
Notes:
• When the low battery symbol ( ) appears on the display, turn the monitor 
off, then replace all batteries at the same time. Long life alkaline batteries 
are recommended.
• The measurement values continue to be stored in memory even after the 
batteries are replaced.
• The supplied batteries may have a shorter life.
 Dispose of the device, components and optional accessories according to 
applicable local regulations. Unlawful disposal may cause environmental 
pollution.
2.2 Setting the Date and Time
Set the monitor to the correct date and time before taking a measurement for 
the first time.
1. Press the   button.
2. Push   or   to change the year.
Push   button to confirm the year and then the month flashes. Repeat the 
same steps to change the month, day, hour, and minute.
3. Press the START/STOP button to turn the monitor off.
Notes:
• If the batteries have been replaced, the date and time setting will need to be 
reset.
• If the date and time are not set, “-:--” appears during or after measurement.
3. Using the Device
3.1 Applying the Arm Cuff
Remove tight-fitting clothing or tight rolled up sleeve from your left upper arm. 
Do not place the arm cuff over thick clothes.
1. Insert the air plug into the air jack 
securely.
2. Wrap the arm cuff firmly in 
place around your left upper 
arm.
The bottom edge of the arm cuff 
should be 1/2 inch (1 to 2 cm) above 
the elbow. Air tube is on the inside of 
your arm and aligned with your middle 
finger.
3. Secure closed with the 
fabric fastener.
Notes:
• When you take a measurement on the right 
arm, the air tube will be at the side of your 
elbow. Be careful not to rest your arm on the 
air tube.
• The blood pressure can differ between the right arm and the left arm, and 
the measured blood pressure values can be different. OMRON recommends 
to always use the same arm for measurement. If the values between both 
arms differ substantially, please check with your physician which arm to use 
for your measurements.
3.2 How to Sit Correctly
To take a measurement, you need to be 
relaxed and comfortably seated, under 
comfortable room temperature. Avoid 
bathing, drinking alcohol or caffeine, 
smoking, exercising or eating 30 minutes 
before taking a measurement.
• Sit on a chair with your feet flat on the floor.
• Sit upright with your back straight.
• Sit with your back and arm being supported.
• The arm cuff should be placed on your arm at 
the same level as your heart.
3.3 Taking a Measurement
Notes:
• To stop a measurement, press the START/STOP button once to deflate the 
arm cuff.
• Remain still while taking a measurement.
The monitor is designed to take measurements and store the measurement 
values in the memory for 2 people using USER ID 1 and USER ID 2.
1. Select your User ID (1 or 2).
2. Press the START/STOP button.
The arm cuff will start to inflate automatically.
3. Remove the arm cuff.
4.
Press the START/STOP button to turn the monitor off.
The monitor automatically stores the measurement result in its memory.
It will automatically turn off after 2 minutes.
Note: Wait 2-3 minutes before taking another measurement. Waiting between 
measurements allows the arteries to return to the condition prior to 
taking a measurement.
Using the Guest Mode
The monitor stores measurement values for 2 users in the memory. 
The guest mode can be used to take a single measurement for another user. 
No measurement values are stored in the memory when the guest mode is 
selected.
1. Press and hold the START/STOP 
button for more than 3 seconds.
The USER ID symbol and the Date/Time 
display will disappear.
2. Release the START/STOP button when the Date/Time display 
turns off.
The arm cuff will start to inflate automatically.
DO NOT adjust medication based on measurement results from this blood 
pressure monitor. Take medication as prescribed by your physician. Only a 
physician is qualified to diagnose and treat High Blood Pressure.
This device is not intended to be a diagnostic device.
Always consult your physician. Self-diagnosis of measurement results and 
self-treatment are dangerous.
Inflating to a higher pressure than necessary may result in bruising where the 
arm cuff is applied.
3.4 Using the Memory Function
The monitor automatically stores the results up to 50 sets for each user (1 and 
2). It can also calculate an average value based on the last 3 measurement 
values taken within 10 minutes.
Notes:
• If there are only 2 measurement values in the memory for that period, the 
average will be based on these 2 values.
• If there is 1 measurement value in the memory for that period, this is 
displayed as the average.
• If the memory is full, the monitor will delete the oldest value.
• When viewing the measurement value taken without setting the date and 
time, “-:--” is displayed instead of the date and time.
To View the Measurement Values Stored in Memory
1. Select your User ID (1 or 2).
2. Press the   button.
The Memory number appears for a second 
before the pulse rate is displayed. 
The newest set is numbered “1”.
3. Press the   or   button to view the values stored in memory.
: To view the older values
: To view the more recent values
To View the Average Value
1. Select your User ID (1 or 2).
2. Press and hold the   button for 
more than 3 seconds.
Notes:
• If the previous measurement was taken without setting the date and time, 
the average value is not calculated.
• If there are no measurements results stored in the memory, 
the screen to the right is displayed.
To Delete All the Values Stored in Memory
The values stored in the memory are deleted by USER ID.
1. Select your User ID (1 or 2).
2. Press the   button, while the memory symbol appears. 
3. While holding the   button 
down, press the 
START/STOP button for 
more than 3 seconds.
Note: You cannot partially delete the values stored in the memory. 
All values for the user you select will be deleted.
Do not damage. Do not break it.
Do not tamper with it. Do not forcibly bend or pull.
Do not twist. Do not bundle during use.
Do not pinch. Do not place under heavy objects.
2298802-0B
5 series 
Blood Pressure Monitor
Model BP742N
Instruction Manual
A. Display
B. Up/Down buttons
C. USER ID selection switch
D. Date/Time setting button
E. START/STOP button
F. Memory button
G. Battery compartment
H. Air jack
I. AC adapter jack 
(for optional AC adapter)
M. USER ID symbol
N. Systolic blood pressure
O. Diastolic blood pressure
P. Low battery symbol
Q. Heartbeat symbol
(Flashes during measurement.)
R. Memory symbol
S. Average value symbol
T. Date/Time display
U. Movement error symbol
V. Irregular heartbeat symbol
W. Blood pressure level indicator
X. Deflation symbol
Y. Pulse display / Memory number
Office Home
Systolic Blood Pressure ≥ 140 mmHg  135 mmHg≥
Diastolic Blood Pressure ≥ 90 mmHg ≥ 85 mmHg
G
H
I
D
A
F
E
B
C
D
D
J
L
K
J. Arm cuff 
(Arm circumference 9” - 17” (22 - 42 cm))
K. Air plug
L. Air tube
N
O
P
R
M
S
T
Q
U
V
W
X
Y
Irregular Heartbeat
Normal Heartbeat
Pulse
Blood pressure
Blood pressure
Short Long
Pulse
Minute
Change Confirm
Change Confirm
Change Confirm
Change Confirm
Change Confirm
Year
Month
Day
Hour
 : Forward
 : Back
1/2 inch
(1 - 2 cm)
START INFLATE DEFLATE COMPLETE
If your systolic pressure is more than 210 mmHg
After the arm cuff starts to inflate, press and hold the START/STOP 
button until the monitor inflates 30 to 40 mmHg higher than your 
expected systolic pressure.
Notes:
• The monitor will not inflate above 299 mmHg.
• Do not apply more pressure than necessary.
Alternating date/time 
display
Specyfikacje produktu
| Marka: | Omron | 
| Kategoria: | Monitor ciśnienia krwi | 
| Model: | BP742N | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Omron BP742N, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Monitor ciśnienia krwi Omron
                        
                         7 Kwietnia 2025
                        
                    
                                                            
                        
                         6 Kwietnia 2025
                        
                    
                                                            
                        
                         6 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025
                        
                    
                                                            
                        
                         4 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         31 Marca 2025
                        
                    
                                                            
                        
                         31 Marca 2025
                        
                    
                                                            Instrukcje Monitor ciśnienia krwi
- Heine
- Lanaform
- Optimum
- Innoliving
- TrueLife
- Withings
- A&D
- Medisana
- Gima
- ProfiCare
- Magic Care
- Hyundai
- Konig
- Terraillon
- Bioland
Najnowsze instrukcje dla Monitor ciśnienia krwi
                        
                         6 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         1 Kwietnia 2025
                        
                    
                                                            
                        
                         31 Marca 2025
                        
                    
                                                            
                        
                         30 Marca 2025
                        
                    
                                                            
                        
                         30 Marca 2025
                        
                    
                                                            
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         17 Marca 2025
                        
                    
                                                            
                        
                         12 Marca 2025