Instrukcja obsługi Palmer PLI-05
                    Palmer
                    
                    Niesklasyfikowane
                    
                    PLI-05
                
                                
    Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Palmer PLI-05 (2 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 3 użytkowników na średnio 4.8 gwiazdek
                        Strona 1/2
                    
                    
                    
PLI – BALUN – LINE ISOLATION BOX – 2 CHANNEL05 
SAFETY INFORMATION
1.  Please read these instructions carefully. 
2.  Keep all information and instructions in a safe place. 
3.  Follow the instructions. 
4.  Observe all safety warnings. Never remove safety warnings or other information from the equipment. 
5.  Use the equipment only in the intended manner and for the intended purpose. 
6.  Use only sufficiently stable and compatible stands and/or mounts (for fixed installations). Make cer-
tain that wall mounts are properly installed and secured. Make certain that the equipment is installed 
securely and cannot fall down. 
7.  During installation, observe the applicable safety regulations for your country. 
8.  Never install and operate the equipment near radiators, heat registers, ovens or other sources of heat. 
Make certain that the equipment is always installed so that is cooled sufficiently and cannot overheat. 
9.  Never place sources of ignition, e.g., burning candles, on the equipment. 
10.  Ventilation slits must not be blocked. 
11.  Do  not  use  this  equipment  in  the  immediate  vicinity  of  water  (does  not  apply  to  special  outdoor 
equipment - in this case, observe the special instructions noted below. Do not expose this equipment 
to flammable materials, fluids or gases. 
12.  Make certain that dripping or splashed water cannot enter the equipment. Do not place containers 
filled with liquids, such as vases or drinking vessels, on the equipment. 
13.  Make certain that objects cannot fall into the device. 
14.  Use this equipment only with the accessories recommended and intended by the manufacturer. 
15.  Open the device for changing the battery, do not modify this equipment. 
16.  After connecting the equipment, check all cables in order to prevent damage or accidents, e.g., due 
to tripping hazards. 
17.  During transport, make certain that  the  equipment cannot  fall  down and  possibly  cause property 
damage and personal injuries.
18.  If your equipment is no longer functioning properly, if fluids or objects have gotten inside the equip-
ment or if it has  been damaged in another way,  switch it off immediately and unplug it from the 
mains outlet (if it is a powered device). This equipment may only be repaired by authorized, qualified 
personnel. 
19.  Clean the equipment using a dry cloth. 
20.  Comply with all applicable disposal laws in your country. During disposal of packaging, please sep-
arate plastic and paper/cardboard. 
21.  Plastic bags must be kept out of reach of children.
22.  If the equipment has been exposed to strong fluctuations in temperature (for example, after trans-
port), do not switch it on immediately. Moisture and condensation could damage the equipment. Do 
not switch on the equipment until it has reached room temperature. 
23.  Do not step on the power cord. Make certain that the power cable does not become kinked, especially 
at the mains outlet and/or power adapter and the equipment connector. 
24.  When connecting the equipment, make certain that the power cord or power adapter is always freely 
accessible. Always disconnect the equipment from the power supply if the equipment is not in use 
or if you want to clean the equipment. Always unplug the power cord and power adapter from the 
power outlet at the plug or adapter and not by pulling on the cord. Never touch the power cord and 
power adapter with wet hands. 
25.  To disconnect the equipment  from the power mains  completely, unplug the power  cord or power 
adapter from the power outlet. 
26.  Unplug the power cord and power adapter from the power outlet if there is a risk of a lightning strike 
or before extended periods of disuse.
CAUTION: 
CA U TI O N
RI SK OF   SELE CTRI C HO CK
DO  N  O NOT PE
There are no user serviceable parts inside. Have repairs carried out only by qualified service personnel. 
CAUTION – HIGH VOLUME LEVELS WITH AUDIO PRODUCTS!
This equipment is intended for professional use. Therefore, commercial use of this equipment is subject 
to the respectively applicable national accident prevention rules and regulations. As a manufacturer, Adam 
Hall is obligated to notify you formally about the existence of potential health risks. Hearing damage due to 
high volume and prolonged exposure: When in use, this product is capable of producing high sound-pres-
sure levels (SPL) that can lead to irreversible hearing damage in performers, employees, and audience 
members. For this reason, avoid prolonged exposure to volumes in excess of 90 dB. 
MANUFACTURER’S WARRANTY & LIMITATION OF LIABILITY 
You can find our current warranty conditions and limitation of liability at: http://www.adamhall.com/media/
shop/downloads/documents/manufacturersdeclarations.pdf
To request warranty service for a product, please contact Adam Hall GmbH, Daimler Straße 9, 61267 Neu 
Anspach / Email Info@adamhall.com / 49 (0) 6081 / 9419-0
        PROPER DISPOSAL OF THIS PRODUCT 
(WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT) 
(Valid in the European Union and other European countries with waste separation) 
This symbol on the product, or the documents accompanying the product, indicates that this appliance 
may not be treated as household waste. This is to avoid environmental damage or personal injury due 
to uncontrolled waste disposal. Please dispose of this product separately from other waste and have it 
recycled to promote sustainable economic activity.
SCOPE OF APPLICATION
Balanced or unbalanced isn’t the question here. BALUN stands for Balanced-Unbalanced. Thanks to the 
stereo TRS jacks used in the PLI05, it can cope with both balanced and unbalanced signals. The PLI05 
is so to say the PLI02’s little sister. Both boxes can be used to convert balanced to unbalanced and both 
use so called line isolating transformers to realize a galvanic separation. They are connected between 
mains powered devices to reliably prevent ground loop hum. The PLI02 was designed for use with XLR 
connections and for low impedances (600 Ohms). The PLI05 on the other hand with its jack connectors is 
better for higher impedances. It covers a wide range from 600 Ohms to over 10 kOhms. To prevent loss of 
level make sure that your input impedance is not higher than the output impedance. 
CONNECTION BALANCED DEVICES
Use shielded two-core cables with stereo jack plugs. These are also called TRS jacks, TRS stands for 
the Tip, Ring and Sleeve of the plug. A balanced connection only makes sense if your device has a 
balanced output. If the device has XLR outputs you will need an XLR to stereo jack adapter cable with 
the following assignments: XLR pin 1 to the jacks’ sleeve, XLR pin 2 to the jacks’ Tip and XLR pin 3 
to the jacks’ ring.
CONVERTING BALANCED TO UNBALANCED
As mentioned earlier, you can use the PLI05 to make an unbalanced signal balanced. Simply use a 
mono jack on the unbalanced side, and a stereo Jack with the same assignments as stated above on 
the balanced side of the PLI05. Important: Balanced wiring is a lot less sensitive to interferences com-
pared to unbalanced setups. Unbalanced cables should therefore always be kept as short as possible.
CAUTION:
All Audio transformers are quite sensitive to magnetic fields caused by mains transformers for example. 
Before you permanently install the PDI05 somewhere, make sure the location is suitable by temporarily 
installing the device.
TECHNICAL SPECIFICATIONS
Product Type: line isolator
Type: passive
Channels: 2
Inputs: 2
Input Connections: 6.3 mm Jack
Max. Input Level: + 6 dBu
Input Impedance: 10 k Ohm(s)
Input Type: balanced / unbalanced (depending on TS/TRS connection)
Outputs: 2
Output Connections: 6.3 mm Jack
Output Type: balanced / unbalanced (depending on TS/TRS connection)
Output Impedance: 600 Ohm(s)
Max. Output Levels: + 6 dBu
Frequency Response: 20 - 20,000 Hz
Transformer-balanced: yes
Ratio: 1:1
Housing Material: die-cast aluminium
Housing Surface: powder coated
Width: 120 mm 
Depth: 60 mm
Height: 35 mm
Weight: 0.28 kg
© Palmer Musical Instruments, Adam Hall GmbH, D-61267 Neu-Anspach, Daimlerstr. 9, Germany TEL: ++49 (0)6081 94190
FAX: ++49 (0)6081 43280 WEB: www.adamhall.com, www.palmer-germany.com EMAIL: info@palmer-germany.com
The casing is grounded on this jack
Specyfikacje produktu
| Marka: | Palmer | 
| Kategoria: | Niesklasyfikowane | 
| Model: | PLI-05 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Palmer PLI-05, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Palmer
                        
                         11 Stycznia 2025
                        
                    
                                                            
                        
                         11 Stycznia 2025
                        
                    
                                                            
                        
                         11 Stycznia 2025
                        
                    
                                                            
                        
                         11 Stycznia 2025
                        
                    
                                                            
                        
                         11 Stycznia 2025
                        
                    
                                                            
                        
                         11 Stycznia 2025
                        
                    
                                                            
                        
                         1 Stycznia 2025
                        
                    
                                                            
                        
                         1 Stycznia 2025
                        
                    
                                                            
                        
                         28 Grudnia 2024
                        
                    
                                                            
                        
                         28 Grudnia 2024
                        
                    
                                                            Instrukcje Niesklasyfikowane
- QuickCool
- GP
- Sprolink
- Electro Harmonix
- Bixolon
- Fostex
- Ozone
- Drive Medical
- Solo
- MediaMatrix
- Anybus
- Shokz
- BakkerElkhuizen
- Topcraft
- Thames & Kosmos
Najnowsze instrukcje dla Niesklasyfikowane
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025