1. Package Contents
Thank you for purchasing PLANET industrial Gigabit Media Converter, 
IGT-805AT. In the following sections, the term “Industrial Gigabit 
Media Converter” mentioned in this user’s manual also means the 
IGT-805AT.
Open the box of the Industrial Gigabit Media Converter and 
carefully unpack it. The box should contain the following items:
Industrial Gigabit 
Media Converter x 1
User's Manual x 1
Wall-mount Plate w/
Screws x 1
DIN-rail Bracket
w/Screws x 1
RJ45 Dust Cap x 1 SFP Dust Cap x 1
If any of these are missing or damaged, please contact your dealer 
immediately; if possible, retain the carton including the original 
packing material, and use them again to repack the product in case 
there is a need to return it to us for repair.
Weight 395g
Power Requirements
DC 12~48V, redundant power with reverse 
polarity protection function.
AC 24V power adapter
Power 
Consumption/ 
Dissipation
2.6 watts/8.8BTU (DC 48V)
Converter Specications
Flow Control
Back pressure for half duplex.
IEEE 802.3x pause frame for full duplex
Fabric 4Gbps
Throughput
(packet per second)
2.97Mpps@64bytes
Maximum 
Transmission Unit
9216 bytes
Network Cables
10/100/1000BASE-T:
Cat3, 4, 5, 5e, 6 UTP cable
(100 meters, max.)
EIA/TIA-568 100-ohm STP
(100 meters, max.)
1000BASE-SX:
50/125μm or 62.5/125μm multi-mode 
ber optic cable, up to 550m
(varying on SFP module)
1000BASE-LX:
9/125μm single-mode ber optic cable, 
up to 10/20/40/60/80/120 kilometers 
(varying on SFP module)
3.2  LED Indicators
 System
LED Color Function
P1 Green Lit: indicates power 1 has power.
P2 Green Lit: indicates power 2 has power.
Alarm Red
Lit: indicates either power 1 or power 2 has no 
power.
 Per 100/1000BASE-X SFP Port
LED Color Function
LNK/
ACT
Green
Lit: indicates the link through that port is 
successfully established at 100Mbps or 1000Mbps.
Blinking: indicates that the Converter is actively 
sending or receiving data over that port.
 Per 10/100/1000BASE-T Port
LED Color Function
LNK/
ACT
Green
Lit: indicates that the Gigabit Ethernet Port 
is successfully connecting to the network at 
10/100/1000Mbps.
Blinking: indicates that the Gigabit Ethernet Port 
is actively sending or receiving data over that port.
1000
LNK/
ACT
Green
Lit: indicates the link through that port is 
successfully established at 1000Mbps.
Blinking: indicates that the Gigabit Ethernet Port 
is actively sending or receiving data over that port.
O: indicates the link through that port is 
successfully established at 10/100Mbps.
3. Hardware Introduction
3.1  Three-View Diagram
The three-view diagram of the Industrial Gigabit Media Converter 
consists of Ethernet interfaces and one removable 6-pin terminal 
block. The LED indicators are also located on the front panel.
 IGT-805AT:
32.00
135.00
87.80
97.10
48.8046.50 39.70
28.00
48.80
53.50 53.50
18.00
15.20
30.00
9.20
40.00
28.0018.00
28.00
18.0028.00
28.00
40.00
163.00
Top View
Side View Front View
Mounting Kit
Mounting Kit
DIN-Rail Kit
Side View
Rear View
Unit: mm
Bottom View
P1 P2
LNK/
ACT
LNK/
ACT
1000
Alarm
IGT-805AT
100/1000X
10/100/1000T
Max. Fault Ala rm Loading: 24V, 1A
DC Input: 12-48V
, 1A max.
AC Input: 24V
, 0.6A max.
V1+
V2+
PWR1
PWR2Alarm
2.ProductSpecications
Model IGT-805AT
Hardware Specications
Copper Interface
1 x 10/100/1000BASE-T RJ45 TP
Auto-MDI/MDI-X, auto-negotiation
Fiber Optic 
Interface
1 1000BASE-SX/LX/BX SFP interface.
Compatible with 100BASE-FX SFP
Connector
Removable 6-pin terminal block
Pin 1/2 for Power 1, Pin 3/4 for fault alarm, 
Pin 5/6 for Power 2
Alarm
Provides one relay output for power failure
Alarm relay current carry ability: 1A @ DC 
24V
LED
3 x LED for System and Power:
 Green: DC Power 1
 Green: DC Power 2
 Red: Power Alarm
2 x LED for Per Copper Port:
 Green: LNK/ACT
 Green:1000 LNK/ACT
1 x LED for Per SFP Interface
 Green: LNK/ACT
ESD Protection 6KV DC
Enclosure IP30 type metal case
Installation DIN rail kit and wall mount ear
Dimensions
(W x D x H)
32 x 87 x 135 mm
Network Cables
100BASE-FX:
50/125μm or 62.5/125μm multi-mode 
ber optic cable, up to 2 kilometers
(varying on SFP module)
9/125μm single-mode ber optic cable, up 
to 20/40/60 kilometers
(varying on SFP module)
Standards Conformance
Standards 
Compliance
IEEE 802.3 Ethernet
IEEE 802.3u Fast Ethernet
IEEE 802.3ab Gigabit Ethernet
IEEE 802.3z Gigabit Ethernet
IEEE 802.3x full-duplex ow control
Regulatory 
Compliance
FCC Part 15 Class A, CE
Stability Testing
IEC 60068-2-32 (free fall)
IEC 60068-2-27 (shock)
IEC 60068-2-6 (vibration)
Environment
Temperature
Operating: -40~75 degrees C
Storage: -40~75 degrees C
Humidity
Operating: 5~95% (non-condensing)
Storage: 5~95% (non-condensing)
  Front Panel
P1 P2
LNK/
ACT
LNK/
ACT
1000
Alarm
IGT-805AT
100/1000X
10/100/1000T
SFP Port
100/1000BASE-X SFP port 
for transceiver module, 
enabling to have a networking 
distance of 550 meters to 2km 
(multi-mode ber) and up to 
10/20/40/60/80/120 kilometers 
(single-mode ber or WDM 
ber).
Gigabit TP Interface
10/100/1000BASE-T 
copper RJ45 twisted-pair 
with up to 100 meters in 
distance.
Figure 2: IGT-805AT Front Panel
3.3  Wiring the Power Inputs
The terminal block connector on the top panel of Industrial Gigabit 
Media Converter is used for 12~48V DC power inputs. Please follow 
the steps below to insert the power wire.
Caution
When performing any of the procedures like inserting 
the wires or tightening the wire-clamp screws, make 
sure the power is OFF to prevent from getting an 
electric shock.
1. Insert positive/negative DC power wires into contacts 1 and 2 for 
POWER 1, or 5 and 6 for POWER 2.
Max. Fault Alarm Loading: 24V, 1A
DC Input: 12-48V
, 1A max.
AC Input: 24V
, 0.6A max.
V1+ V2+
PWR1
PWR2Alarm
1  2  3  4  5  6
2. Tighten the wire-clamp screws for preventing the wires from 
loosening.
1 2 3 4 5 6
Power 1 Alarm Power 2
+ - + -
Specyfikacje produktu
| Marka: | Planet | 
| Kategoria: | Niesklasyfikowane | 
| Model: | IGT-805AT | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Planet IGT-805AT, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Planet
                        
                         8 Stycznia 2025
                        
                    
                                                            
                        
                         8 Stycznia 2025
                        
                    
                                                            
                        
                         8 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         7 Grudnia 2024
                        
                    
                                                            
                        
                         7 Grudnia 2024
                        
                    
                                                            Instrukcje Niesklasyfikowane
- Voodoo Lab
- Gentrax
- Celestron
- August
- Lehle
- Steinel
- Consul
- Traeger
- Videotel Digital
- MXL
- Anova
- Balt
- Dimplex
- Razor
- Eonon
Najnowsze instrukcje dla Niesklasyfikowane
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025