R ision 1. ( 2/ /201 ) ev 2 1 127
Us Man ler ua
EC301
Potentiostat Gal nostat / va
St f t san ord Research Sys em
Certification
Stanford Research Systems certifies that this product met its published specifications at the time of shipment.
Warranty
This Stanford Research Systems product is warranted against defects in materials and workmanship for a
period of one (1) year from the date of shipment.
Service
For warranty service or repair, this product must be returned to a Stanford Research Systems authorized
service facility. Contact Stanford Research Systems or an authorized representative before returning this
product for repair.
Information in this document is subject to change without notice.
Copyright Stanford Research Systems, Inc., 2012 2017. All rights reserved.©
Stanford Research Systems, Inc.
1290–D Reamwood Avenue
Sunnyvale, CA 94089 USA
Phone: (408) 744-9040 Fax: (408) 744-9049
www.thinkSRS.com e-mail: info@thinkSRS.com
Printed in U.S.A. Document number 9-01712-903
2 Potentiostat/Galvanostat/ZRAEC301
Contents
1 General information 6
1.1 Safety and preparation for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.2 Unpacking.............................................. 7
1.2.1 Standardequipment.................................... 7
1.2.2 Accessories......................................... 7
1.2.3 Optionalequipment.................................... 7
1.3 Symbols you may find on SRS products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.4 Specications ............................................ 9
1.5 Serial number and firmware revision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2 EC301 basics 20
2.1 Software ............................................... 20
2.2 Functionalblockdiagram...................................... 20
2.3 Polarityconvention......................................... 22
2.4 Connecting the EC19 to the EC301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
2.4.1 NecessaryItems ...................................... 22
2.4.2 Steps ............................................ 23
3 Operation 24
3.1 Frontpanel ............................................. 24
3.1.1 Power-onreset....................................... 24
3.1.2 Bandwidthlimit...................................... 25
3.1.3 CElimit .......................................... 25
3.1.4 Cell............................................. 25
3.1.5 External electrometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.1.6 Voltage........................................... 26
3.1.7 Current........................................... 26
3.1.8 Mode ............................................ 27
3.1.9 Rotatingelectrode..................................... 27
3.1.10 Analog output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
3.1.11 Current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.1.12 IR compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
3.1.13 External input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3.1.14 Measurement setup/control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.1.15 Knob ............................................ 33
3.1.16 Congure.......................................... 34
3.1.17 Remote status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3.2 Rearpanel.............................................. 36
3.2.1 Powerentry ........................................ 36
3.2.2 GPIBinterface....................................... 36
3.2.3 Ethernet interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.2.4 Current interrupt synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.2.5 Timebase synchronization input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.2.6 Scan trigger input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
3.2.7 Program output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40E/I
3.2.8 Scan synchronization output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
3.2.9 Auxiliary ADC inputs (1-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
3.2.10 Resistance temperature detector (RTD) input . . . . . . . . . . . . . . . . . . . . . 43
3.2.11 Grounding posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
3.2.12 Raw analog outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
3.2.13 CEmonitor ........................................ 46
3.2.14 Synchronous ADC input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
3


Specyfikacje produktu

Marka: SRS
Kategoria: nieskategoryzowany
Model: EC301

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z SRS EC301, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą