Stanley Stud Sensor 300
The Stud Sensor 300 uses electronic signals to locate the center of studs, joists
or live AC wires through drywall or other common building materials. Once
the center of a stud has been detected in one pass across the surface, the
Stud Sensor 300 gives a visual display and sounds an audible tone. A marking
channel allows you to easily note the stud center and edges on the wall.
The Stud Sensor 300 will not detect objects in concrete, mortar, block or brick
work, carpeting, foil faced materials, metallic surfaces or ceramic tiles. The
Stud Sensor 300 is not designed to locate non-ferrous or plastic objects such
as pipes.
Note: Read all instructions prior to operating the Stud Sensor 300 and DO NOT
remove any labels from the tool.
WARNING:
Protect Your Eyes, Wear Safety Goggles.
Usage
Detecting Wood / Metal Studs
2 Hold the Stud Sensor 300 at
against the surface, making rm
contact.
3 Press in and hold the activation
button. A series of tones will sound.
Note:The unit cannot be moved before
calibration is complete.
6 / 7When it detects the stud
center, the “Center” icon will appear on
the LCD and an audible tone will sound.
Use the marking channel located at the
top of the unit to mark the stud center.
OPERATING INSTRUCTIONS
Battery
1 Open door on back of unit and connect a 9 volt battery
(not included)to clip. Put battery back into case and close
back battery door.
Note: Recommend to replace a new 9 volt battery
when low battery - “Low Battery” will appear on the
LCD.
10 If all segments of the LCD ash on and off when
the activation button is pressed, move the Stud Sensor
300 to a different location and try again. Releasing the
activation button will turn off the sensor.
Note:While calibrating, the Stud Sensor 300 must not
be placed directly over a stud, dense material such as
metal, or over a wet or newly painted area, or it will not
properly calibrate.
8 Slide the Stud Sensor 300 slowly across the surface in a straight line.
As it detects a stud, the unit will display the relative position of the stud
on the screen.
Marking Channel
Live Wire Warning LED
LCD Display
Activation Button
METAL SCAN Mode
Stud Location Graphic
Self-Calibration Complete
Depth Detection Mode
4 When the unit is calibrated the
“Ready” icon will appear on the LCD.
5 Keep holding the activation button
during all of the following procedures.
Note: Once the Activation button is
released, the unit shuts off.
STUD or METAL / AC Mode Selection
Live Wire Detected
STUD Mode
Low Battery Indicator
AC TRACKING Mode

Oceń tę instrukcję

4.9/5 (2 Recenzje)

Specyfikacje produktu

Marka: Stanley
Kategoria: Niesklasyfikowane
Model: S300

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Stanley S300, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Stanley

Stanley

Stanley SL229 Instrukcja

8 Października 2024
Stanley

Stanley SL227 Instrukcja

8 Października 2024
Stanley

Stanley SHR263 Instrukcja

8 Października 2024
Stanley

Stanley RL HW+ Instrukcja

3 Października 2024
Stanley

Stanley STWB8902P Instrukcja

2 Października 2024
Stanley

Stanley TLM660 Instrukcja

23 Września 2024
Stanley

Stanley FCL-G Instrukcja

19 Września 2024
Stanley

Stanley AL24 Instrukcja

9 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Smallrig
Qsc

QSC TSC-8 Instrukcja

29 Stycznia 2025
Xtrarm
Sunding
Xtrarm
Xtrarm
Osee

OSEE TX402 Instrukcja

29 Stycznia 2025