Xtender
XTH
Data may change without any notice
* Adjustable with the RCC-02/-03
** These features are valid only when using the cooling module ECF-01.
(1)
With -01 at the end of the reference, means 120V/60Hz. Available for all Xtenders except XTH 8000-48
Model
Inverter
Nominal battery voltage 12 Vdc 24 Vdc 48 Vdc
Input voltage range 9.5 - 17 Vdc 19 - 34 Vdc 38 - 68 Vdc
Continuous power @ 2C 2500 VA 4500 VA 5000 VA 7000 VA
Power 30 min. @ 25°C 3000 VA 5000 VA 6000 VA 8000 VA
Power 5 sec. @ 2C 7.5 kVA 12 kVA 15 kVA 21 kVA
Maximum load Up to short-circuit
Asymmetric load Up to Pcont.
* Load detection (stand-by) 2 to 25 W
Cos j
0.1-1
Maximum efciency 93 % 94 % 96 %
Consumption OFF/Stand-by/ON 1.2 W / 1.4 W / 14 W 1.4 W / 1.8 W / 18 W 1.8 W / 2.2 W / 22 W 1.8 W / 2.4 W / 30 W
* Output voltage Pure sine wave 230 Vac (± 2 %) / 120 Vac
(1)
* Output frequency Adjustable 45 - 60 Hz
(1)
± 0.05 % (crystal controlled)
Harmonic distortion < 2 %
Overload and short-circuit protection Automatic disconnection with 3 time restart attempt
Overheat protection Warning before shut-off - with automatic restart
Battery charger
* Charge Characteristic
6 steps: Bulk, Absorption, Floating, Equalization, reduced oating, periodic absorption
Number of steps, thresholds, end current and times completely adjustable with the RCC-02/-03
* Maximum charging current 160 A 140 A 100 A 120 A
* Temperature compensation With BTS-01 or BSP 500/1200
Power Factor Correction (PFC) EN 61000-3-2
General data
* Input voltage range 150 to 265 Vac / 50 to 140 Vac
(1)
Input frequency 45 to 65 Hz
Input current max. (transfer relay) / Output current max.
50 Aac / 56 Aac 50 Aac / 80 Aac
Transfer time < 15 ms
Multifunction contacts 2 independent contacts (potential free 3 points, 16 Aac / 5 Adc)
Weight 34 kg 40 kg 42 kg 46 kg
Dimensions h/w/l [mm] 230 / 300 / 500 230 / 300 / 500 230 / 300 / 500
Protection index IP20
EU declaration of conformity
Low Voltage Directive (LVD) 2014/35/EU:
- EN 50178:1997
Electromagnetic Compliance (EMC) Directive 2014/30/EU:
- EN 62040-2:2006, EN 61000-3-2:2014, EN 61000-3-12:2011
Operating temperature range -20 to 5C
Relative humidity in operation 95 % without condensation
Ventilation Forced from 55°C
Acoustic level <40 dB / <45 dB (without/with ventilation)
Warranty 5 years
ISO Certication 9001:2008 / 14001:2004
Accessories
Remote control RCC-02 or RCC-03
llll
Module Xcom-232i
llll
Communication sets Xcom-LAN /w Xcom-GSM / Xcom-SMS
llll
Battery Status Processor BSP
llll
Remote Control Module RCM-10 (3 m)
2 aux. contacts module ARM-02
Cooling Module ECF-01
Battery temp. sensor BTS-01 (3 m)
llll
Communication cable for 3ph and // CAB-RJ45-8-2
llll
Mounting frame X-Connect
llll


Specyfikacje produktu

Marka: Studer
Kategoria: Ładowarka baterii
Model: XTH 3000-12

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Studer XTH 3000-12, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Ładowarka baterii Studer

Studer

Studer XTM 3500-24 Instrukcja

3 Października 2024
Studer

Studer XTH 3000-12 Instrukcja

3 Października 2024
Studer

Studer XTH 8000-48 Instrukcja

3 Października 2024
Studer

Studer XTM 2600-48 Instrukcja

3 Października 2024

Instrukcje Ładowarka baterii

Najnowsze instrukcje dla Ładowarka baterii