FEATURES
AGM maintenance-free lead-acid battery
High-e ciency lead-calcium platesffi
Construction of ber-glass separatorsfi
stabilizes temperature of electrolyte
High-quality insulation of plates
Safe system of internal pressure regulating
valves
Reduced self-discharge current
Sealed construction
Long cycle life both in oat and cycle chargefl
modes
Quality of products is guaranteed by the
control of the manufacturing process in
accordance with the standards
12 V
7 A h at 20Hr-rate to 1.75V/cell•
2.14 Kg
6
18 m (Fully Charged) at 25 °CΩ
Average 3% of capacity declined per
month at 25 °С
Discharge: -20 °C ~ 50 °C
Charge: -15 °C ~ 40 °C
Storage: -20 °C ~ 40 °C
105 A (5 sec.)
40 °C 102%
25 °C 100%
0 °C 85%
-15 °C 65%
ABS plastic
Nominal Voltage
Nominal Capacity
Approx. Weight
Number of cells in battery
Internal Resistance
Self-Discharge
Operating Temp. Range
Max. Discharge Current
Capacity
A ected by Temp.ff
Container Material
SPECIFICATION
CHARGE PROCEDURE DISCHARGE CURRENT VS. DISCHARGE VOLTAGE
Application Final Discharge
Voltage (V/cell)
Discharge
Current (A)
Constant Voltage Charge (V/cell)
Temperature Set Point Allowable Range
Max. Charge
Current
Cycle Use
Standby Use
25 °C
25 °C
2.425
0.3C
2.275
2.40~2.45
2.25~2.30
Note: Temp. Compensation Coef cient of Charge Voltage,fi
Cycle use: -4mV/°C/cell, Standby Use: -3 mV/°C/cell
1.75 1.70 1.60
0.2C>(A) 0.2C<(A)<1C (A)>1C
APPLICATION
All Purpose
UPS
Signal Light
Alarm and Security System
DC Power Supply
Auto Control System
APPLICABLE STANDARDS
IEC61056-1/2
JIS C8702-2003
GB/T19639.1-2005
CI C
ISO14001
TB 0907 59 35
ISO9001
C
C
C
C
CQ
Q
Q
Q
Q
C
C
C
C
C
MH 47104
you want - we can
Rechargeable VRLA Battery
SV1270

F.V.
(V/cell)
1.60
1.70
1.75
1.80
1.85
Charge current
Temperature: 25°C
100% (0.05C×20H)
50% (0.05C×10H)
Charge
Charge Voltage: 2.275V/cell
Charge Сurent: 0.1CA
Discharge
Charge quantity
Battery Voltage
0.02
0.05
1.40
1.60
1.80
2.00
2.20
2.40
2.60
0.08
0.11
0.14
0.17
0.20
120
140
13.0
12.0
11.0
10.0
9.00
Terminal Voltage (V)
0.16C 0.093C 0.05C
0.62C
0.35C
1C3C
Discharge Time
min Hr
201051 2301231.2 6
.
0.6 24
20 24
Charge Time (Hr)
0 4 8 12 16
0
00
60
40
20
80
100
1
2
3
151±1.5
Time
Model
12001000800600400
20
40
60
80
100
Length
151 ± 1.5
Width
65 ± 1.5
Height
94 ± 1.5
Total height
98 ± 2
Unit: mm
Terminal Type
Terminal F1 Terminal F2
3.05
6.1
3.6
8.1
4.8
94±1.5
98±2
0.72
6.20.72
OUTER DIMENSION
40
60
80
100
2018161412108
6
42
0
0
Capacity Retention Ratio (%)
No supplementary charge required
(Carry out supplementary charge
before use if 100%capacityis required)
Supplementary charge required
before use.
This supplementary charge will help
to recover the capacity and should
be made as early as possible.
Supplementary charge may often
fail to recover the capacity.
The battery should never be left
standing till this state is reached.
Supplementary charge and storage guidelines
25°C30°C40°C
5°C
200
30% DOD
0
Capacity (%)
120
CC(A)
CP(W)
5 Min 10 Min 15 Min 30 Min 1 Hr 2 Hr 3 Hr 4 Hr 5 Hr 8 Hr 10 Hr 20 Hr
25.2 16. 5 12.3 8.1 4.2 2.45 1.8 1.45 1.23 0.81 0.66 0.36
297 187 141 85 48 28.4 20.85 16.74 14.20 9.36 7.67 4.20
23.1 15.8 11. 3 7.6 3.9 2.35 1.75 1.4 1.20 0.8 0.65 0.35
280 177 133 85 46 27.2 20.27 16.22 13.94 9.22 7.53 4.08
21 14.8 10.5 7.4 3.8 2.3 1.72 1.33 1.20 0.79 0.64 0.35
270 172 127 84 44 26.7 19.92 15.4 13.85 9.13 7.47 4.05
20.2 14.1 9.8 7.2 3.7 2.25 1.69 1.31 1.14 0.77 0.63 0.34
237 166 122 84 43 26.1 19.69 15.21 13.24 8.75 7.29 3.97
18.7 13.3 9.1 7.0 3.6 2.19 1.6 1.28 1.09 0.75 0.61 0.33
229 161 116 83 42 26.0 19.1 15.17 12.95 8.46 7.15 3.94
Note: The above data are average values, and can be obtained with 3 charge/discharge cycles.
CC(A)
CP(W)
CC(A)
CP(W)
CC(A)
CP(W)
CC(A)
CP(W)
Constant Current (CC,Unit: A) & Constant Power (CP, Unit: W) Discharge Table at 25°C
65±1.5
100% DOD 50% DOD
Ambient Temperature: 25 °C
Battery Voltage (V/Per Cell)
Charge Current (CA)
Charge Quantity (%)
Discharge Characteristics at 25 °C Charge characteristics (Standby use)
Storage Period (Month)
Capacity retention characteristics
Number of Cycles (Times)
Cycle Service life
Specyfikacje produktu
Marka: | Sven |
Kategoria: | Niesklasyfikowane |
Model: | SV1270 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Sven SV1270, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Sven
7 Stycznia 2025
31 Grudnia 2025
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
Instrukcje Niesklasyfikowane
- Niesklasyfikowane 2box
- Niesklasyfikowane IKRA
- Niesklasyfikowane Carel
- Niesklasyfikowane Adonit
- Niesklasyfikowane Nikon
- Niesklasyfikowane Monoprice
- Niesklasyfikowane Campomatic
- Niesklasyfikowane Palm
- Niesklasyfikowane BABY Born
- Niesklasyfikowane Livarno Lux
- Niesklasyfikowane Biltema
- Niesklasyfikowane Eligent
- Niesklasyfikowane Audix
- Niesklasyfikowane Akuvox
- Niesklasyfikowane Overtone Labs
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025