MDR- 10 series
10W Single Output Industrial DIN Rail Power Supply
File Name:MDR- -SPEC 2017-1110
SPECIFICATION
Features:
• Universal AC input / Full range
• Protections: Short Circuit / Overload / Over voltage
• Cooling by free air convection
• Can be installed on DIN rail TS-35/7.5 or 15
• Built in DC OK active signal
• LED indicator for power on
• No load power consumption<0.75W
• 100% full load burn-in test
MODEL
MDR- -10 12
OUTPUT
DC VOLTAGE
12V
RATED CURRENT
0.84A
CURRENT RANGE
0 ~ 0.84A
RATED POWER
10W
RIPPLE & NOISE (max.) Note.2
120mVp-p
VOLTAGE TOLERANCE Note.3
±3.0%
LINE REGULATION
±1.0%
LOAD REGULATION
±3.0%
SETUP, RISE TIME Note.5
500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
120ms/230VAC 25ms/115VAC at full load
INPUT
VOLTAGE RANGE
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
81%
AC CURRENT (Typ.)
0.33A/115VAC 0.21A/230VAC
INRUSH CURRENT (Typ.)
COLD START 35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
PROTECTION
OVERLOAD
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
13.8 ~ 16.2V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION
DC OK ACTIVE SIGNAL (max.)
9 ~ 13.5V / 40mA
ENVIRONMENT
WORKING TEMP.
-20 ~ +70 (Refer to "Derating Curve")℃
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85 , 10 ~ 95% RH℃
TEMP. COEFFICIENT
±0.03%/ (0 ~ 50℃ ℃)
VIBRATION
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY &
EMC
(Note 4)
SAFETY STANDARDS
UL508, TUV EN60950-1 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
EMC EMISSION
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3- -32,
EMC IMMUNITY
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A
OTHERS
MTBF
584K hrs min. MIL-HDBK-217F (25 )℃
DIMENSION
22.5*90*100mm (W*H*D)
PACKING
0.17Kg; 72pcs/13.2Kg/0.91CUFT
NOTE
1. All parameters NOT Specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. “ ” ”
5. Length of set up time is measured at cold first start. Turning ON/OFF power supply may lead to increase to the set up time.
..

MDR- 10 series
10W Single Output Industrial DIN Rail Power Supply
File Name:MDR- -SPEC 2017-1110
35
22.5
5 5
Case No. 956 Unit:mm
100
+V -V DC
OK
DC OK
N L
Install DIN rail TS35/7.5 or TS35/15
5 5
fosc : 60KHz
I/P
EMI
FILTER
RECTIFIERS
&
FILTER
POWER
SWITCHING
DC OK
+V
-V
FG
O.L.P.
CONTROL
(a) signal (b) (c) Relay 5V LED
DC OK
V-
R
5.1V
DC OK
R
V-
DC OK
V-
Relay RL
100
80
60
40
20
Others
5V
100
90
80
70
60
50
40
- 0 (VERTICAL)20 10 20 30 40 50 60 70
85 95
100
115
120
140
160
180
200
220
240
264
AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz℃
Output Derating VS Input Voltage
Derating Curve
O.V.P.
Block Diagram
Application of DC OK Active Signal
DETECTION
CIRCUIT
RECTIFIERS
&
FILTER
DC OK
Mechanical Specification
LOAD (%)
90
LOAD (%)
Model
R
5V
≧ Ω200
12V
≧ Ω1.5K
15V
≧ Ω2K
24V
≧ Ω3.9K
Model
R
5V
≧ Ω1K
12V
≧ Ω2.4K
15V
≧ Ω3K
24V
≧ Ω4.7K
Model
RL
5V
≧ Ω120
12V
≧ Ω700
15V
≧ Ω700
24V
≧ Ω1.2K
Specyfikacje produktu
Marka: | Vivotek |
Kategoria: | Niesklasyfikowane |
Model: | MDR-10 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Vivotek MDR-10, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Vivotek
16 Września 2024
16 Września 2024
15 Września 2024
15 Września 2024
15 Września 2024
14 Września 2024
14 Września 2024
14 Września 2024
14 Września 2024
14 Września 2024
Instrukcje Niesklasyfikowane
- Niesklasyfikowane VOX
- Niesklasyfikowane Artecta
- Niesklasyfikowane Humminbird
- Niesklasyfikowane Noordi
- Niesklasyfikowane Hurricane
- Niesklasyfikowane AirLive
- Niesklasyfikowane Ferm
- Niesklasyfikowane Vaddio
- Niesklasyfikowane Kemo
- Niesklasyfikowane Klein Tools
- Niesklasyfikowane Duro
- Niesklasyfikowane Indesit
- Niesklasyfikowane Megableu
- Niesklasyfikowane AV Tool
- Niesklasyfikowane Audioline
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025