Instrukcja obsługi Cotech J5218D


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Cotech J5218D (6 stron) w kategorii nieskategoryzowany. Ta instrukcja była pomocna dla 17 osób i została oceniona przez 9 użytkowników na średnio 4.7 gwiazdek

Strona 1/6
GREAT BRITAIN • CUSTOMER SERVICE contact number: 0845 300 9799 e-mail: customerservice@clasohlson.co.uk internet: www.clasohlson.com/uk
6 7 8 9
1 2 3 4 5
Ver. 20140428
Ceiling Light
Art.no 36-4833 Model J5218D
36-4834 J5236D
36-4835 J5258D
Please read theentire instruction manual before using theproduct
and save it for future reference. Wereserve theright for any errors
in text or images and any necessary changes made to technical
data. Ifyou have any questions regarding technical problems
please contact our Customer Services.
1. Safety
This light fitting is only suitable for permanent installation and
should be installed by aqualified electrician.
Keep your proper footing and balance at alltimes.
Make sure that there are no hidden cables or water pipes in
theceiling before drilling holes.
Read all theinstructions before you install and use thelightfitting.
Always turn off thepower before installing, wiring or repairing
thelight fitting.
The light fitting must not be used without thediffuser inplace.
Warning: Whenever installing any electrical fittings, basic
safety precautions should always be observed to avoid therisk
of fire, electric shock and personal injury.
Ifyou drill holes in thefitting it will affect Note:
theIPclassification of thefitting.
2. Product description
Ceiling light (IP65). Suitable for industrial use and in facilities
with high levels of dust, dirt and contaminants.
Ideal for garages, machine rooms and stables.
Clear UV-proof polycarbonate diffuser.
CE-, D- and S-marked.
For T8 fluorescent tubes (sold separately).
The light fitting has abuilt-in electronic ballast for aflicker-free
and energy-efficient operation.
No glow starters are required.
3. Parts
4. Preparations
Remove theinstallation components from inside thelight
fitting’s chassis.
Gather all thetools necessary to perform theinstallation.
Select anappropriate location for thelight fitting.
Think about theorder in which theparts need to be fitted.
Purchase thecorrect type of fluorescent tubes.
See section.Specifications
1. Turnthelocking knob (4) to release thechassis plate (3).
2. Liftthechassis plate and take out theinstallation components.
3. Unhookthespring clips (2) from thechassis plate.
4. Readythechassis plate: Pushthefluorescent tube holders (1)
through thechassis plate, make sure they are secured. 8. Maintenance
Always turn off thepower before carrying out any maintenance.
You may only replace thefluorescent tube yourself – any other
repairs should be carried out by aqualified electrician.
Only use fluorescent tubes that match thespecifications.
Repairs must only be carried out by qualified personnel using
original spareparts.
Replacing the fluorescent tube
Note: Bearin mind that thetube is fragile and should be handled
withcare.
1. Turnoff theelectricity.
2. Waituntil thefluorescent tube has cooled.
3. Removethediffuser by opening thesnaplocks.
4. Turnthefluorescent tube a¼ turn so it can pass through
theslot in theholder, remove thefluorescent tube.
5. Fitthenewtube.
6. Refitthediffuser. Thelight fitting must not be used without
thediffuser inplace.
9. Disposal
This product should be disposed of in accordance with local
regulations. If you are unsure how to proceed, contact your
localauthority.
10. Specifications
36-4833
Model J5218D
Power supply 230 V AC, 50Hz
Fluorescent tube T8, socket G13, 2×18W
Dimensions 660×125×86mm
Weight 0.77kg
Protection class IP65
Number of snap locks 6
36-4834
Model J5236D
Power supply 230 V AC, 50Hz
Fluorescent tube T8, socket G13, 2×36W
Dimensions 1260×125×86mm
Weight 2.12kg
Protection class IP65
Number of snap locks 8
36-4835
Model J5258D
Power supply 230 V AC, 50Hz
Fluorescent tube T8, socket G13, 2×58W
Dimensions 1560×125×86mm
Weight 2.45kg
Protection class IP65
Number of snap locks 10
The product conforms to relevant safety standards and is CE-,
D- and S-marked.
1. Fluorescent tube holder
2. Springclip
3. Chassis plate
4. Chassis plate locking knob
5. Diffuser
6. Snaplock
7. Hanging bracket
8. Cablegland
9. Screwsand wallplugs
5. Assembly
1. Fitthesnap locks (6) to themounts on thecasing.
2. Fitthecable gland (8) into thecasing with thethin rubber
washer on theoutside and anut on theinside. Tighten
thecable gland so that it does not spin when you tighten
theouter seal after thecable has been fitted.
3. Thinkabout how you are going to fix thefitting to theceiling.
There are two alternatives: Hangit from theceiling on awire/
chain attached to thehanging brackets (6) or hang it directly
to theceiling on thehanging brackets.
Alternative 1
Secure awire or chain to theceiling and to thehanging
brackets and then adjust thelength of thewire/chain until
thelight fitting is at thedesired height.
Alternative 2
a) Start by measuring where theholes are to be drilled.
b) Screw thehanging brackets to theceiling using
theincluded screws and wallplugs.
c) Check that everything is ready before you push thelight
fitting into thehanging brackets.
5. Pressthelight fitting up into thehanging brackets.
6. Electrical connections
Note: Thelight fitting has anelectronic ballast and therefore needs
no glow starters.
1. Turnthepower off before beginning any wiring.
2. Themains cable should have aminimum cross-sectional area
of 1.5 mm². Thecircuit must be protected by a10 Afuse.
3. Makesure that thecable gland is fitted properly so that no
water can enter through thehole.
4. Passthemains cable through thecable gland. Makesure
thatthere is at least 17.5 cm of cable inside thecasing of
thelight fitting.
5. Connect thewires to thecorrect terminals (L, earth and N).
Theearth must always be connected.
6. Tighten thesealing nut on thecable gland. Trypulling
thecable gently to make sure that it is held firmly by thegland
and that theseal istight.
7. Reattach thespring clips to thechassis plate and hold
thechassis plate against thelight fitting. Lockthechassis
plate in place by turning thelocking knob.
8. ).Insertthefluorescent tubes (see Replacing thefluorescent tube
9. Carefully fit thediffuser and lock it in place using all
thesnaplocks.
7. Cleaning
1. Turn off thepower and wait until thelight fitting has cooled.
Removethediffuser by opening thesnaplocks.
2. Clean using asoft cloth. Ifnecessary, moisten slightly with
water and mild detergent. Never use alcohol, solvent or similar
agents to clean thelight.
3. Refit thediffuser.


Specyfikacje produktu

Marka: Cotech
Kategoria: nieskategoryzowany
Model: J5218D

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Cotech J5218D, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Cotech

Cotech

Cotech J5218D Instrukcja

2 Września 2024
Cotech

Cotech 36-6286 Instrukcja

2 Września 2024
Cotech

Cotech 51097X23 Instrukcja

2 Września 2024
Cotech

Cotech 50053 Instrukcja

2 Września 2024
Cotech

Cotech EMT306CD Instrukcja

2 Września 2024
Cotech

Cotech TD9511-3 Instrukcja

2 Września 2024
Cotech

Cotech JSRF-601G Instrukcja

2 Września 2024
Cotech

Cotech PTC17 Instrukcja

2 Września 2024
Cotech

Cotech RDC100J Instrukcja

1 Września 2024

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Asko

Asko DBI644MIB.S.TW/1 Instrukcja

28 Października 2024
Asko

Asko DFS233IB.S.TW/1 Instrukcja

28 Października 2024
Emko

Emko EZM-9920 Instrukcja

27 Października 2024
Emko

Emko ESM-3712-H Instrukcja

27 Października 2024
Emko

Emko ATS-10 Instrukcja

27 Października 2024
Emko

Emko EAOM-11.2 Instrukcja

27 Października 2024
Emko

Emko EPM-3790 Instrukcja

27 Października 2024
Emko

Emko EPM-7790 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux IAN 108340 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux HG06009A-BS Instrukcja

27 Października 2024